摘要
AHV-364可控震源广泛应用于野外地震勘探,在实际应用中经常发生可控震源散热器爆裂问题。本文分析了AHV-364可控震源散热器爆裂的原因并提出了解决方案。
The AHV-364 vibrator is widely used in seismic exploration,the burst problem of hydraulic oil cooler often occurs in the practical application.This paper analyzes the cause of hydraulic oil cooler blowout and puts forward the solution.
作者
梁福河
吴宏利
占春启
胡万国
方涛
Liang Fuhe;Wu Hongli;Zhan Chunqi;Hu Wanguo;Fang Tao
出处
《物探装备》
2020年第1期44-46,共3页
Equipment for Geophysical Prospecting
关键词
液压波动
储能器
散热器
二级溢流阀
pressure fluctuation
accumulator
cooler
secondary relief valve