期刊文献+

平滑肌电刺激技术治疗产后42天后会阴疼痛的探索性研究 被引量:7

Exploratory study on the treatment of perineal pain after 42 days postpartum with smooth muscle electrical stimulation
下载PDF
导出
摘要 目的探讨平滑肌电刺激技术在产后42 d后会阴疼痛治疗中的应用效果。方法回顾性选择2017年3月至2018年12月于淮南市妇幼保健院门诊就诊,并于盆底治疗中心行产后盆底功能检测的产后42~90 d会阴疼痛的产妇66例,采用随机数字表法将产妇分为研究组和对照组,每组各33例。对照组产妇口服消炎痛治疗,研究组产妇在此基础上联合平滑肌电刺激技术治疗,比较两组会阴疼痛的治疗效果、产妇盆底功能、阴道动态压力及产妇性生活质量。结果研究组产妇的会阴疼痛治疗有效率(100%)显著高于对照组(87.88%),差异具有统计学意义(P<0.05)。研究组产妇的阴道动态压力(3.75±1.31)cm H2O明显高于对照组(2.89±0.77)cm H2O,盆底功能影响评分(PFIQ-7评分)(14.62±3.67)分、盆底功能障碍评分(PFDI-20评分)(4.97±1.48)分、盆底肌张力评分(1.24±0.35)分明显低于对照组(21.49±5.33)分、(8.89±1.79)分、(1.77±0.42)分,差异均具有统计学意义(P<0.05)。研究组产妇的性关系评分(18.22±1.16)分、性困难评分(17.39±0.82)分、性高潮评分(18.51±0.54)分、疾病的影响评分(18.09±0.71)分、性满意度评分(18.39±0.50)分均显著高于对照组(15.65±1.38)分、(15.84±0.62)分、(14.49±0.69)分、(15.24±0.63)分、(15.56±1.84)分,差异均具有统计学意义(P<0.05)。结论对产后42 d后会阴疼痛产妇进行平滑肌电刺激技术治疗,可有效减轻产妇的会阴疼痛程度,提高产妇的性生活质量,效果良好,值得推荐。 Objective To investigate the effect of smooth muscle electrical stimulation on the treatment of perineal pain after 42 days postpartum.Methods 66 cases of postpartum parturient women who visited the outpatient department of Huainan Maternal and Child Health Hospital from March 2017 to December 2018 and underwent postpartum pelvic floor function test in the pelvic floor treatment center were retrospectively selected.The women were divided into the study group and the control group randomly,33 cases in each group.The women in the control group were treated with oral anti-inflammatory treatment,and the women in the study group were treated with smooth muscle electrical stimulation on this basis.The therapeutic effect,pelvic floor function,vaginal dynamic pressure and sexual quality of life between the two groups were compared.Results The effective rate of perineal pain treatment in the study group(100%)was significantly higher than that in the control group(87.88%).The difference between the two groups was statistically significant(P<0.05).The vaginal dynamic pressure in the study group(3.75±1.31)cm H2 O was significantly higher than that in the control group(2.89±0.77)cm H2 O.The Pelvic Floor Impact Questionnaire(PFIQ-7),Pelvic Floor Distress Inventory-20(PFDI-20)and pelvic floor muscle tension score of the study group were(14.62±3.67),(4.97±1.48)and(1.24±0.35)respectively,significantly lower than those of the control group(21.49±5.33),(8.89±1.79),(1.77±0.42).The differences between the two groups were statistically significant(P<0.05).The scores of sexual relationship(18.22±1.16),sexual difficulty(17.39±0.82),orgasm(18.51±0.54),disease influence(18.09±0.71)and sexual satisfaction(18.39±0.50)in the study group were significantly higher than those in the control group(15.65±1.38),(15.84±0.62),(14.49±0.69),(15.24±0.63),(15.56±1.84).The differences between the two groups were statistically significant(P<0.05).Conclusion The treatment of smooth muscle electrical stimulation for women with perineal pai
作者 余琳 程艳 张娟 徐友姣 YU Lin;CHENG Yan;ZHANG Juan(Obstetric Rehabilitation Center,Huainan Maternal and Child Health Hospital,Huainan Anhui 232007,China)
出处 《临床和实验医学杂志》 2020年第5期546-549,共4页 Journal of Clinical and Experimental Medicine
基金 安徽省教育厅支持项目(编号:KJ2015B089by).
关键词 会阴疼痛 平滑肌电刺激技术 盆底功能 阴道动态压力 性生活质量 Perineal pain Smooth muscle electrical stimulation technique Pelvic floor function Vaginal dynamic pressure Sexual life quality
  • 相关文献

参考文献13

二级参考文献77

共引文献163

同被引文献92

引证文献7

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部