摘要
介绍了GCXD 10 0 0型床位单位消毒器臭氧消毒方法 ,并用GCXD 10 0 0型床位单位消毒器和紫外线灯对两间病房同时进行消毒对比。结果说明两种方法在物体表面消毒效果中无明显差异 ;在病房空气消毒中 ,前者略优于后者 ;在物体各面消毒效果中 ,前者明显胜于后者。结论 :臭氧杀菌范围比紫外线更为广泛 。
It was introduced in this paper that the effect of the ozone disinfection of GCXD 1000 model in a sickroom. The two sickrooms were disinfected with the GCXD 1000 and the ultraviolet lamp at the same time. The result shows that the disinfecting effect was no obviously different on the surface of the objects between both of them. The disinfecting effect of the former in air of the sickrooms was a little better than the latter. The effect of the former on each surface of the objects was much better than the latter. The conclusion is that the scope of ozone disinfection is much wider than ultraviolet and the ozone disinfection is more suitable for sickrooms.
出处
《现代科学仪器》
2002年第6期57-58,共2页
Modern Scientific Instruments