Isothermal hot compression tests were carried out on Mg-3.0Nd-0.2Zn-0.4Zr (mass fraction, %, NZ30K) alloy using a Gleeble-3500 thermo-simulation machine at temperatures ranging from 350 to 500 ℃and strain rates fro...Isothermal hot compression tests were carried out on Mg-3.0Nd-0.2Zn-0.4Zr (mass fraction, %, NZ30K) alloy using a Gleeble-3500 thermo-simulation machine at temperatures ranging from 350 to 500 ℃and strain rates from 0.001 to 1 s^-1. A correction of flow stress for deformation heating at a high strain rate was carried out. Based on the corrected data for deformation heating, a hyperbolic sine constitutive equation was established. The constants in the constitutive equation of the hyperbolic sine form were determined as a function of strain. The flow stresses predicted by the developed equation agree well with the experimental results, which confirms that the developed constitutive equations can be used to predict the flow stress of NZ30K alloy during hot deformation.展开更多
The effects of biodegradable Mg?6Zn alloy on tight junction of intestinal epithelial cells (IEC-6) were investigated. In the in vitro experiments, the cells were exposed to Mg?6Zn alloy extracts with different concent...The effects of biodegradable Mg?6Zn alloy on tight junction of intestinal epithelial cells (IEC-6) were investigated. In the in vitro experiments, the cells were exposed to Mg?6Zn alloy extracts with different concentrations (0, 20% and 40%) for 1, 3 and 5 d. The real-time polymerase chain reaction (PCR) results show that when the cells are treated with 40% and 20% extracts, the expression of Zona Occludens 1 (ZO-1) and Occludin increase as compared with those in the control group. In the in vivo experiments, Mg?6Zn alloy and titanium staples were implanted into rabbits’ intestinal tract for 1, 2 and 3 weeks. By immunohistochemical staining of peri-implant intestinal tissue, increased expression of Occludin and ZO-1 are observed in the Mg?6Zn alloy groups as compared with those in the titanium and control groups. The results show that Mg?6Zn alloy in intestine may promote the regeneration of tight junction, and the extract with a certain concentration can induce the expression of tight junction related genes in IEC-6 cells.展开更多
基金Project (2009AA033501) supported by High-tech Research and Development Program of ChinaProject (08DZ1150302) supported by the Science and Technology Commission Foundation Program of Shanghai Municipality, ChinaProject (0911) supported by Shanghai Automotive Industry Science and Technology Development Foundation, China
文摘Isothermal hot compression tests were carried out on Mg-3.0Nd-0.2Zn-0.4Zr (mass fraction, %, NZ30K) alloy using a Gleeble-3500 thermo-simulation machine at temperatures ranging from 350 to 500 ℃and strain rates from 0.001 to 1 s^-1. A correction of flow stress for deformation heating at a high strain rate was carried out. Based on the corrected data for deformation heating, a hyperbolic sine constitutive equation was established. The constants in the constitutive equation of the hyperbolic sine form were determined as a function of strain. The flow stresses predicted by the developed equation agree well with the experimental results, which confirms that the developed constitutive equations can be used to predict the flow stress of NZ30K alloy during hot deformation.
基金Project(30901422)supported by the National Natural Science Foundation of ChinaProject(YG2010MS45)supported by Shanghai Jiao Tong University Interdisciplinary(Biomedical Engineering)Research Fund,ChinaProject(09XJ21005)supported by School of Medicine Science and Technology Fund,Shanghai Jiao Tong University,China
文摘The effects of biodegradable Mg?6Zn alloy on tight junction of intestinal epithelial cells (IEC-6) were investigated. In the in vitro experiments, the cells were exposed to Mg?6Zn alloy extracts with different concentrations (0, 20% and 40%) for 1, 3 and 5 d. The real-time polymerase chain reaction (PCR) results show that when the cells are treated with 40% and 20% extracts, the expression of Zona Occludens 1 (ZO-1) and Occludin increase as compared with those in the control group. In the in vivo experiments, Mg?6Zn alloy and titanium staples were implanted into rabbits’ intestinal tract for 1, 2 and 3 weeks. By immunohistochemical staining of peri-implant intestinal tissue, increased expression of Occludin and ZO-1 are observed in the Mg?6Zn alloy groups as compared with those in the titanium and control groups. The results show that Mg?6Zn alloy in intestine may promote the regeneration of tight junction, and the extract with a certain concentration can induce the expression of tight junction related genes in IEC-6 cells.