A dual wavelength differential first derivative spectrophotometric method has been developed to standardize the concentration of a saturated aqueous solution of carbon monoxide (CO) as the standard and to identify and...A dual wavelength differential first derivative spectrophotometric method has been developed to standardize the concentration of a saturated aqueous solution of carbon monoxide (CO) as the standard and to identify and to determine CO formed during the microsomal metabolism of xenobiotics in vitro. The method can significantly eliminate the background interference in the assay media and increase the quantitative accuracy and the sensitivity. There is a good linear relationship between CO concentration in the range of 2~10 μmol·L 1 CO and the distance D between the first derivative peak at 415 nm amd valley at 426 nm with r=0.9999(n=5),the regression equation being C (mmol·L 1 )=17.6D 0.4, the detection limit lower than 0.1 μmol·L 1 CO. The average recoveries of CO from the assay system and the sample were 102.1%, RSD=2.9% (n=7) and 79.7%, RSD=6.8% (n=12),respectively. The RSD of within day was 4.4%(n=18),and the RSD of day to day was 6.1%(n=16). By this method, four trihaloanilines and one trihalobenzene were tested, the results showed that only 2,4,5 trifluoroaniline could be converted to CO by the incubation with rat hepatic microsomes, NADPH and oxygen, the ability of phenobarbital or dexamethasone to induce rat hepatic microsomes to catalyze CO formation was 3 or 8 times higher than that of the control.展开更多
Broad-band all-optical wavelength conversion of differential phase-shift keyed (DPSK) signal is experimentally demonstrated. This scheme is composed of a one-bit delay interferometer demodulation stage followed by a...Broad-band all-optical wavelength conversion of differential phase-shift keyed (DPSK) signal is experimentally demonstrated. This scheme is composed of a one-bit delay interferometer demodulation stage followed by a semiconductor optical amplifier (SOA) based nonlinear polarization switch. A wavelength converter for the 10 G b/s DPSK signal is presented, which has a wide wavelength range of more than 30 nm. The converted signals experience small power penalties less than 1.4 dB compared with the original signal, at a bit error rate of 10-9. Additionally, the optical spectra, the measured waveforms and the open eye diagrams of the converted signals show a high quality wavelength conversion performance.展开更多
文摘A dual wavelength differential first derivative spectrophotometric method has been developed to standardize the concentration of a saturated aqueous solution of carbon monoxide (CO) as the standard and to identify and to determine CO formed during the microsomal metabolism of xenobiotics in vitro. The method can significantly eliminate the background interference in the assay media and increase the quantitative accuracy and the sensitivity. There is a good linear relationship between CO concentration in the range of 2~10 μmol·L 1 CO and the distance D between the first derivative peak at 415 nm amd valley at 426 nm with r=0.9999(n=5),the regression equation being C (mmol·L 1 )=17.6D 0.4, the detection limit lower than 0.1 μmol·L 1 CO. The average recoveries of CO from the assay system and the sample were 102.1%, RSD=2.9% (n=7) and 79.7%, RSD=6.8% (n=12),respectively. The RSD of within day was 4.4%(n=18),and the RSD of day to day was 6.1%(n=16). By this method, four trihaloanilines and one trihalobenzene were tested, the results showed that only 2,4,5 trifluoroaniline could be converted to CO by the incubation with rat hepatic microsomes, NADPH and oxygen, the ability of phenobarbital or dexamethasone to induce rat hepatic microsomes to catalyze CO formation was 3 or 8 times higher than that of the control.
文摘Broad-band all-optical wavelength conversion of differential phase-shift keyed (DPSK) signal is experimentally demonstrated. This scheme is composed of a one-bit delay interferometer demodulation stage followed by a semiconductor optical amplifier (SOA) based nonlinear polarization switch. A wavelength converter for the 10 G b/s DPSK signal is presented, which has a wide wavelength range of more than 30 nm. The converted signals experience small power penalties less than 1.4 dB compared with the original signal, at a bit error rate of 10-9. Additionally, the optical spectra, the measured waveforms and the open eye diagrams of the converted signals show a high quality wavelength conversion performance.