Objective The present study aimed to evaluate the accuracy of the factorial method for estimating energy needs in individuals living in China.Methods Sixteen healthy female adults aged 22.1±1.2 years with a body ...Objective The present study aimed to evaluate the accuracy of the factorial method for estimating energy needs in individuals living in China.Methods Sixteen healthy female adults aged 22.1±1.2 years with a body mass index (kg/m 2) of 20.4±1.7 were selected as subjects.In free-living conditions,energy expenditure (EE) was determined by using the factorial method.At the same time,the doubly labeled water method (DLW) was also used to measure energy expenditure of the subjects and served as the criterion method.EE predicted by the factorial method (EE factorial) was compared with the simultaneous measurement of EE by the validated DLW method (EE DLW).Results There was excellent agreement between EE factorial (7.46±0.59 MJ/d) and EE DLW (7.64 ± 0.49 MJ/d),with a difference of-2.6±4.9% (-0.18±0.36 MJ/d).No significant differences were found between the two methods.EE factorial was highly correlated with EE DLW (r=0.795,P0.001) and a good agreement for individuals was found by using the Bland and Altman test.Conclusion The factorial method gives satisfactory estimates of EE for both groups and individuals living in China.展开更多
This study aimed to explore the disinfection of drinking water in trunk water mains, based on published conditions denoted within the Irish Republic. The variables within the study were consumer draw-off rates, trunk ...This study aimed to explore the disinfection of drinking water in trunk water mains, based on published conditions denoted within the Irish Republic. The variables within the study were consumer draw-off rates, trunk main length, pipe diameter, and water temperature. All these factors are known to impact the free chlorine residual in operational supply networks. Based on published conditions obtained within the literature review, 60 hypothetical trunk mains were generated for this study. Of primary concern were the variables that affect the chlorine decay rate;total amount of chlorine decay;available amount of chlorine in the periphery of the trunk main;and the costs associated with effective chlorine disinfection of trunk mains. Based on the analysis performed, the following were the salient observations: 1) Low consumer draw-off rates and increased trunk main length and diameter increased the risk of the free chlorine residual in the periphery of the trunk mains not complying with the Environmental Protection Agency’s (EPA) minimum recommended residual value of 0.1 mg/l (EPA Drinking Water Audit Report, 2014). 2) Increasing the diameter of the trunk main from 125 mm to 180 mm had a negligible effect on the chlorine decay rate. However, increasing the trunk main diameter from 125 mm to 180 mm was shown to have a major impact on the total amount of chlorine decay and free chlorine residual available in the periphery of the main. The key parameters that affected disinfection costs associated with trunk mains include length, diameter and the need for chlorine boosting.展开更多
Purpose:The purpose of this study was to compare established methods with newly-developed methods for estimating the total energy expenditure(TEE). Methods:The study subjects comprised 46 individuals,including 16 midd...Purpose:The purpose of this study was to compare established methods with newly-developed methods for estimating the total energy expenditure(TEE). Methods:The study subjects comprised 46 individuals,including 16 middle-aged men(mean age 51.4 years),14 middle-aged women(mean age 49.9 years) and 16 young women(mean age 19.1 years).The TEE was estimated from 24-h heart rate(HR) data using newly-developed software (MoveSense HRAnalyzer 201 la,RC1.Suunto Oy,Vantaa,Finland),and was compared against the TEE determined using doubly labeled water (DLW).Agreement between the two methods was analyzed using Bland and Altman plots. Results:The HR method yielded similar TEE values as the DLW method at the group level,with an average of 8.6 kcal/day in the difference in the mean,but with large individual variations.Forty-four(96%) out of 46 subjects fell within±2SD of the mean difference in TEE comparisons, and there was no tendency towards under- or over-estimation. Conclusion:Our results indicate that the current software using HR analysis for the estimation of daily TEE needs further development for use with free-living individuals.展开更多
基金国家重点基础发展规划项目 [G1 9990 436 0 1 ( 973) ] WaterEnvironment and Food Security :Integrating Economic and EnvironmentalObjective-ACase Study of the Haihe River Basin in China资助
基金supported by the National Natural Science Foundation of China (No. 30771811)the Scientific Research Foundation of Hebei Medical University for the Young Core Instructor (No. 30900143)
文摘Objective The present study aimed to evaluate the accuracy of the factorial method for estimating energy needs in individuals living in China.Methods Sixteen healthy female adults aged 22.1±1.2 years with a body mass index (kg/m 2) of 20.4±1.7 were selected as subjects.In free-living conditions,energy expenditure (EE) was determined by using the factorial method.At the same time,the doubly labeled water method (DLW) was also used to measure energy expenditure of the subjects and served as the criterion method.EE predicted by the factorial method (EE factorial) was compared with the simultaneous measurement of EE by the validated DLW method (EE DLW).Results There was excellent agreement between EE factorial (7.46±0.59 MJ/d) and EE DLW (7.64 ± 0.49 MJ/d),with a difference of-2.6±4.9% (-0.18±0.36 MJ/d).No significant differences were found between the two methods.EE factorial was highly correlated with EE DLW (r=0.795,P0.001) and a good agreement for individuals was found by using the Bland and Altman test.Conclusion The factorial method gives satisfactory estimates of EE for both groups and individuals living in China.
文摘This study aimed to explore the disinfection of drinking water in trunk water mains, based on published conditions denoted within the Irish Republic. The variables within the study were consumer draw-off rates, trunk main length, pipe diameter, and water temperature. All these factors are known to impact the free chlorine residual in operational supply networks. Based on published conditions obtained within the literature review, 60 hypothetical trunk mains were generated for this study. Of primary concern were the variables that affect the chlorine decay rate;total amount of chlorine decay;available amount of chlorine in the periphery of the trunk main;and the costs associated with effective chlorine disinfection of trunk mains. Based on the analysis performed, the following were the salient observations: 1) Low consumer draw-off rates and increased trunk main length and diameter increased the risk of the free chlorine residual in the periphery of the trunk mains not complying with the Environmental Protection Agency’s (EPA) minimum recommended residual value of 0.1 mg/l (EPA Drinking Water Audit Report, 2014). 2) Increasing the diameter of the trunk main from 125 mm to 180 mm had a negligible effect on the chlorine decay rate. However, increasing the trunk main diameter from 125 mm to 180 mm was shown to have a major impact on the total amount of chlorine decay and free chlorine residual available in the periphery of the main. The key parameters that affected disinfection costs associated with trunk mains include length, diameter and the need for chlorine boosting.
基金funded by the Academy of Finlandthe Finnish Ministry of Education,Suunto Oy+2 种基金the Shanghai overseas distinguish professor award program 2011the Shanghai Key Lab of Human Performance(No.11DZ2261100)2012 National Science and Technology Infrastructure Program(Grant No. 2012BAK21B00).
文摘Purpose:The purpose of this study was to compare established methods with newly-developed methods for estimating the total energy expenditure(TEE). Methods:The study subjects comprised 46 individuals,including 16 middle-aged men(mean age 51.4 years),14 middle-aged women(mean age 49.9 years) and 16 young women(mean age 19.1 years).The TEE was estimated from 24-h heart rate(HR) data using newly-developed software (MoveSense HRAnalyzer 201 la,RC1.Suunto Oy,Vantaa,Finland),and was compared against the TEE determined using doubly labeled water (DLW).Agreement between the two methods was analyzed using Bland and Altman plots. Results:The HR method yielded similar TEE values as the DLW method at the group level,with an average of 8.6 kcal/day in the difference in the mean,but with large individual variations.Forty-four(96%) out of 46 subjects fell within±2SD of the mean difference in TEE comparisons, and there was no tendency towards under- or over-estimation. Conclusion:Our results indicate that the current software using HR analysis for the estimation of daily TEE needs further development for use with free-living individuals.