To understand the potential causes of laboratory-acquired infections and to provide possible solutions that would protect laboratory personnel, samples from a viral laboratory were screened to determine the main sourc...To understand the potential causes of laboratory-acquired infections and to provide possible solutions that would protect laboratory personnel, samples from a viral laboratory were screened to determine the main sources of contamination with six subtypes of Rhinovirus. Rhinovirus contamination was found in the gloves, cuffs of protective wear, inner surface of biological safety cabinet (BSC) windows, and trash handles. Remarkably, high contamination was found on the inner walls of the centrifuge and the inner surface of centrifuge tube casing in the rotor. Spilling infectious medium on the surface of centrifuge tubes was found to contribute to contamination of centrifuge surfaces. Exposure to sodium hypochlorite containing no less than 0.2 g/L available chlorine decontaminated the surface of the centrifuRe tubes from Rhinovirus after 2 min.展开更多
Objective: To investigate the viral contamination of invasive medical instruments in dentistry and to provide health administrative institutions with surveillance data. Methods: Sterilized samples were randomly collec...Objective: To investigate the viral contamination of invasive medical instruments in dentistry and to provide health administrative institutions with surveillance data. Methods: Sterilized samples were randomly collected from the department of dentistry to detect HBV-DNA, HCV-RNA, HIV-RNA and HBsAg. Results: Of the invasive medical instruments that were ster- ilized with 2% glutaraldehyde, one of the samples was positive for HBV-DNA, and another sample was positive for HBsAg. Conclusion: Though massive virus contamination of invasive medical instruments in dentistry has been reduced to a low level, the occurrence of contamination still remains.展开更多
基金supported by the China Mega-Project for Infectious Disease(2011ZX10004-001,2012ZX10004401,2012ZX10004215,and 2013ZX10004805002)the SKLID Development Grant(2011SKLID104)
文摘To understand the potential causes of laboratory-acquired infections and to provide possible solutions that would protect laboratory personnel, samples from a viral laboratory were screened to determine the main sources of contamination with six subtypes of Rhinovirus. Rhinovirus contamination was found in the gloves, cuffs of protective wear, inner surface of biological safety cabinet (BSC) windows, and trash handles. Remarkably, high contamination was found on the inner walls of the centrifuge and the inner surface of centrifuge tube casing in the rotor. Spilling infectious medium on the surface of centrifuge tubes was found to contribute to contamination of centrifuge surfaces. Exposure to sodium hypochlorite containing no less than 0.2 g/L available chlorine decontaminated the surface of the centrifuRe tubes from Rhinovirus after 2 min.
基金Project (Nos. 021103128 and 2003C13015) supported by the De-partment of Science and Technology of Zhejiang Province, China
文摘Objective: To investigate the viral contamination of invasive medical instruments in dentistry and to provide health administrative institutions with surveillance data. Methods: Sterilized samples were randomly collected from the department of dentistry to detect HBV-DNA, HCV-RNA, HIV-RNA and HBsAg. Results: Of the invasive medical instruments that were ster- ilized with 2% glutaraldehyde, one of the samples was positive for HBV-DNA, and another sample was positive for HBsAg. Conclusion: Though massive virus contamination of invasive medical instruments in dentistry has been reduced to a low level, the occurrence of contamination still remains.