We report an extremely rare case of an unmptured non-communicating rudimentary horn full-term pregnancy. A woman who had a uterine malformation was misdiagnosed as uterus didelphys and gave birth to a live, healthy fe...We report an extremely rare case of an unmptured non-communicating rudimentary horn full-term pregnancy. A woman who had a uterine malformation was misdiagnosed as uterus didelphys and gave birth to a live, healthy fetus. The correct diagnosis was not made until cesarean section at 37 4/7 weeks. The case suggests that women who are pregnant in a rudimentary horn could obtain a full-term delivery and give birth to a live and healthy baby.展开更多
Background: Labor induction has a low success rate, especially in primiparas with unruptured membranes. Previous studies focused on pregnant women with unruptured membranes, but none specifically targeted primiparas. ...Background: Labor induction has a low success rate, especially in primiparas with unruptured membranes. Previous studies focused on pregnant women with unruptured membranes, but none specifically targeted primiparas. Aims: To compare the effectiveness of a controlled-release dinoprostone vaginal delivery system for cervical dilatation (PROPESS) with that of mechanical dilation for labor induction in primiparous women with unruptured membranes. Materials and Methods: We retrospectively analyzed the data of 90 primiparas with unruptured membranes (41 and 49 in the PROPESS and mechanical dilation groups, respectively). The primary outcome was the cesarean section (CS) rate. The secondary outcomes were the prevalence of vaginal delivery within 12 or 24 h after the initial insertion, oxytocin usage rate, chorioamnionitis, additional use of mechanical dilation in the PROPESS group, and neonatal outcomes. Results: The CS rate was significantly lower in the PROPESS group than in the mechanical dilation group (p = 0.02). A total of 13 patients (31.7%) delivered within 24 h with PROPESS alone, indicating a significantly higher rate of delivery within 24 h in the PROPESS group (p = 0.02). Fewer patients required additional oxytocin in the PROPESS group than in the mechanical dilation group (p = 0.001). However, 14 (34%) patients in the PROPESS group required additional mechanical cervical dilation, resulting in a longer time to delivery than mechanical dilation. Conclusions: PROPESS significantly reduced CS rates and increased delivery rates 24 h after the initial insertion in primiparas with unruptured membranes compared to mechanical dilatation. However, failure to respond to PROPESS resulted in an overall longer delivery time than that of the conventional mechanical dilation group;therefore, identifying predictors of response to PROPESS is necessary.展开更多
Objective:The objective of this research was to explore the difference and correlation of the morphological and hemodynamic features between sidewall and bifurcation aneurysms in anterior circulation arteries,utilizin...Objective:The objective of this research was to explore the difference and correlation of the morphological and hemodynamic features between sidewall and bifurcation aneurysms in anterior circulation arteries,utilizing computational fluid dynamics as a tool for analysis.Methods:In line with the designated inclusion criteria,this study covered 160 aneurysms identified in 131 patients who received treatment at Union Hospital of Tongji Medical College,Huazhong University of Science and Technology,China,from January 2021 to September 2022.Utilizing follow-up digital subtraction angiography(DSA)data,these cases were classified into two distinct groups:the sidewall aneurysm group and the bifurcation aneurysm group.Morphological and hemodynamic parameters in the immediate preoperative period were meticulously calculated and examined in both groups using a three-dimensional DSA reconstruction model.Results:No significant differences were found in the morphological or hemodynamic parameters of bifurcation aneurysms at varied locations within the anterior circulation.However,pronounced differences were identified between sidewall and bifurcation aneurysms in terms of morphological parameters such as the diameter of the parent vessel(Dvessel),inflow angle(θF),and size ratio(SR),as well as the hemodynamic parameter of inflow concentration index(ICI)(P<0.001).Notably,only the SR exhibited a significant correlation with multiple hemodynamic parameters(P<0.001),while the ICI was closely related to several morphological parameters(R>0.5,P<0.001).Conclusions:The significant differences in certain morphological and hemodynamic parameters between sidewall and bifurcation aneurysms emphasize the importance to contemplate variances in threshold values for these parameters when evaluating the risk of rupture in anterior circulation aneurysms.Whether it is a bifurcation or sidewall aneurysm,these disparities should be considered.The morphological parameter SR has the potential to be a valuable clinical tool for promptly distinguishing展开更多
文摘We report an extremely rare case of an unmptured non-communicating rudimentary horn full-term pregnancy. A woman who had a uterine malformation was misdiagnosed as uterus didelphys and gave birth to a live, healthy fetus. The correct diagnosis was not made until cesarean section at 37 4/7 weeks. The case suggests that women who are pregnant in a rudimentary horn could obtain a full-term delivery and give birth to a live and healthy baby.
文摘Background: Labor induction has a low success rate, especially in primiparas with unruptured membranes. Previous studies focused on pregnant women with unruptured membranes, but none specifically targeted primiparas. Aims: To compare the effectiveness of a controlled-release dinoprostone vaginal delivery system for cervical dilatation (PROPESS) with that of mechanical dilation for labor induction in primiparous women with unruptured membranes. Materials and Methods: We retrospectively analyzed the data of 90 primiparas with unruptured membranes (41 and 49 in the PROPESS and mechanical dilation groups, respectively). The primary outcome was the cesarean section (CS) rate. The secondary outcomes were the prevalence of vaginal delivery within 12 or 24 h after the initial insertion, oxytocin usage rate, chorioamnionitis, additional use of mechanical dilation in the PROPESS group, and neonatal outcomes. Results: The CS rate was significantly lower in the PROPESS group than in the mechanical dilation group (p = 0.02). A total of 13 patients (31.7%) delivered within 24 h with PROPESS alone, indicating a significantly higher rate of delivery within 24 h in the PROPESS group (p = 0.02). Fewer patients required additional oxytocin in the PROPESS group than in the mechanical dilation group (p = 0.001). However, 14 (34%) patients in the PROPESS group required additional mechanical cervical dilation, resulting in a longer time to delivery than mechanical dilation. Conclusions: PROPESS significantly reduced CS rates and increased delivery rates 24 h after the initial insertion in primiparas with unruptured membranes compared to mechanical dilatation. However, failure to respond to PROPESS resulted in an overall longer delivery time than that of the conventional mechanical dilation group;therefore, identifying predictors of response to PROPESS is necessary.
文摘Objective:The objective of this research was to explore the difference and correlation of the morphological and hemodynamic features between sidewall and bifurcation aneurysms in anterior circulation arteries,utilizing computational fluid dynamics as a tool for analysis.Methods:In line with the designated inclusion criteria,this study covered 160 aneurysms identified in 131 patients who received treatment at Union Hospital of Tongji Medical College,Huazhong University of Science and Technology,China,from January 2021 to September 2022.Utilizing follow-up digital subtraction angiography(DSA)data,these cases were classified into two distinct groups:the sidewall aneurysm group and the bifurcation aneurysm group.Morphological and hemodynamic parameters in the immediate preoperative period were meticulously calculated and examined in both groups using a three-dimensional DSA reconstruction model.Results:No significant differences were found in the morphological or hemodynamic parameters of bifurcation aneurysms at varied locations within the anterior circulation.However,pronounced differences were identified between sidewall and bifurcation aneurysms in terms of morphological parameters such as the diameter of the parent vessel(Dvessel),inflow angle(θF),and size ratio(SR),as well as the hemodynamic parameter of inflow concentration index(ICI)(P<0.001).Notably,only the SR exhibited a significant correlation with multiple hemodynamic parameters(P<0.001),while the ICI was closely related to several morphological parameters(R>0.5,P<0.001).Conclusions:The significant differences in certain morphological and hemodynamic parameters between sidewall and bifurcation aneurysms emphasize the importance to contemplate variances in threshold values for these parameters when evaluating the risk of rupture in anterior circulation aneurysms.Whether it is a bifurcation or sidewall aneurysm,these disparities should be considered.The morphological parameter SR has the potential to be a valuable clinical tool for promptly distinguishing