The present-day power system is a complex network that caters to the demands of several applications with diverse energy requirements.Such a complex network is susceptible to faults caused due to several reasons such ...The present-day power system is a complex network that caters to the demands of several applications with diverse energy requirements.Such a complex network is susceptible to faults caused due to several reasons such as the failure of the equipment,hostile weather conditions,etc.These faults if not detected in the real-time may lead to cascading failures resulting in a blackout.These blackouts have catastrophic consequences which result in a huge loss of resources.For example,a blackout in 2004 caused an economic loss of 10 billion U.S dollars as per the report of the Electricity Consumers Resource Council.Subsequent investigation of the blackout revealed that the catastrophe could have been prevented if there was an early warning system.Similar other blackouts across the globe forced the power system engineers to devise an effective solution for real-time monitoring and control of the power system.The consequence of these efforts is the wide area measurement system(WAMS).The WAMS consists of several sensors known as the phasor measurement units(PMUs)that collect the real information pertaining to the health of the power grid.This information in the form time synchronized voltage and current phasors is communicated to the central control center or the phasor data concentrator(PDC)where the data is analyzed for detection of power system anomalies.The communication of the synchrophasor data from each PMU to the PDC constitutes the synchrophasor communication system(SPCS).Thus,the SPCS can be considered as the edifice of the WAMS and its reliable operation is essential for the effective monitoring and control of the power system.This paper presents a comprehensive review of the various synchrophasor communication technologies,communication standards and applications.It also identifies the existing knowledge gaps and the scope for future research work.展开更多
Based on the high-accuracy data obtained from the GPS measurements carried out in 1992, 1995 and 1996, the isochronous active units with different kinematic property inside the North China area have been distinguished...Based on the high-accuracy data obtained from the GPS measurements carried out in 1992, 1995 and 1996, the isochronous active units with different kinematic property inside the North China area have been distinguished, 4 active units and 1 transition zone with distinct differential movement have been determined. They are Ordos-Yinshan unit, Yanshan unit, Shanxi-Hebei-Shandong (Jin-Ji-Lu) unit, Jiaodong-Liaoning-Shandong (Jiao-Liao-Lu) unit and Yanshan-Hebei (Yan-Ji) transition zone. The relative movements among the neighboring units in this period have been given. ① The compressive movement between Ordos-Yinshan unit and Yanshan unit is not obvious with an amount of 0.4(1.3 mm/a.②in-Ji-Lu unit moves E40(S off the Ordos-Yinshan unit and the magnitude is 4.4(1.0 mm/a. ③elative to the Yan-Ji transition zone of differential movement, Yanshan unit shifts W38(N with a value of 2.4(1.3 mm/a and Jin-Ji-Lu unit moves eastward 35( by south with an amount of 2.3(0.9 mm/a. ④Jin-Ji-Lu unit has a tensional left-lateral movement of 4.7(1.4 mm/a in the direction of E37(S relative to Yanshan unit. ⑤ Some area near Tanlu belt which is located in the southern part of Jin-Ji-Lu block has a southward movement 14( by west with a magnitude of 1.5(1.1 mm/a off the Jin-Ji-Lu unit. ⑥ Relative to Jin-Ji-Lu unit, Jiao-Liao-Lu unit has a trend of clockwise movement with a tensional right-lateral motion at the north end which neighbors Yanshan unit and a compressive motion at the south end. It should be noted that the errors given in the paper are obtained based on the divergence among the displacements of the sites in the unit, rather than the value calculated from the displacement error of the sites. The analyzed results indicate that: ① Shanxi tectonic zone and Yan-Ji transition zone are the major tectonic active zones to show the frame and magnitude of interior relative movement in North China area, and others are the secondary tectonic active zones; ② The complete horizontal deformation in the North China area is not homo展开更多
To completely eliminate the time delays caused by phasor data compressions for real-time synchrophasor applications,a real-time synchrophasor data compression(RSDC)is proposed in this paper.The two-way rotation charac...To completely eliminate the time delays caused by phasor data compressions for real-time synchrophasor applications,a real-time synchrophasor data compression(RSDC)is proposed in this paper.The two-way rotation characteristic and elliptical trajectory of dynamic synchrophasors are introduced first to enhance the compressions along with a fast solving method for elliptical trajectory fitting equations.The RSDC for phasor data compression and reconstruction is then proposed by combining the interpolation and extrapolation compressions.The proposed RSDC is verified by both the actual phasor measurement data recorded in a two-phase short-circuit incident and a subsynchronous oscillation incident,and the synthetic dynamic synchrophasors.It is also compared with two previous real-time phasor data compression techniques,i.e.,phasor swing door trending(PSDT)and exception and swing door trending(SDT)data compression(ESDC).The verification results demonstrate that RSDC can achieve significantly higher compression ratios for offline applications with the interpolation and the zero-delay phasor data compression with the extrapolation for real-time applications simultaneously.展开更多
文摘The present-day power system is a complex network that caters to the demands of several applications with diverse energy requirements.Such a complex network is susceptible to faults caused due to several reasons such as the failure of the equipment,hostile weather conditions,etc.These faults if not detected in the real-time may lead to cascading failures resulting in a blackout.These blackouts have catastrophic consequences which result in a huge loss of resources.For example,a blackout in 2004 caused an economic loss of 10 billion U.S dollars as per the report of the Electricity Consumers Resource Council.Subsequent investigation of the blackout revealed that the catastrophe could have been prevented if there was an early warning system.Similar other blackouts across the globe forced the power system engineers to devise an effective solution for real-time monitoring and control of the power system.The consequence of these efforts is the wide area measurement system(WAMS).The WAMS consists of several sensors known as the phasor measurement units(PMUs)that collect the real information pertaining to the health of the power grid.This information in the form time synchronized voltage and current phasors is communicated to the central control center or the phasor data concentrator(PDC)where the data is analyzed for detection of power system anomalies.The communication of the synchrophasor data from each PMU to the PDC constitutes the synchrophasor communication system(SPCS).Thus,the SPCS can be considered as the edifice of the WAMS and its reliable operation is essential for the effective monitoring and control of the power system.This paper presents a comprehensive review of the various synchrophasor communication technologies,communication standards and applications.It also identifies the existing knowledge gaps and the scope for future research work.
基金The National Key Basic Research Project Mechanism and Prediction of Continental Earthquakes (G1998040700).
文摘Based on the high-accuracy data obtained from the GPS measurements carried out in 1992, 1995 and 1996, the isochronous active units with different kinematic property inside the North China area have been distinguished, 4 active units and 1 transition zone with distinct differential movement have been determined. They are Ordos-Yinshan unit, Yanshan unit, Shanxi-Hebei-Shandong (Jin-Ji-Lu) unit, Jiaodong-Liaoning-Shandong (Jiao-Liao-Lu) unit and Yanshan-Hebei (Yan-Ji) transition zone. The relative movements among the neighboring units in this period have been given. ① The compressive movement between Ordos-Yinshan unit and Yanshan unit is not obvious with an amount of 0.4(1.3 mm/a.②in-Ji-Lu unit moves E40(S off the Ordos-Yinshan unit and the magnitude is 4.4(1.0 mm/a. ③elative to the Yan-Ji transition zone of differential movement, Yanshan unit shifts W38(N with a value of 2.4(1.3 mm/a and Jin-Ji-Lu unit moves eastward 35( by south with an amount of 2.3(0.9 mm/a. ④Jin-Ji-Lu unit has a tensional left-lateral movement of 4.7(1.4 mm/a in the direction of E37(S relative to Yanshan unit. ⑤ Some area near Tanlu belt which is located in the southern part of Jin-Ji-Lu block has a southward movement 14( by west with a magnitude of 1.5(1.1 mm/a off the Jin-Ji-Lu unit. ⑥ Relative to Jin-Ji-Lu unit, Jiao-Liao-Lu unit has a trend of clockwise movement with a tensional right-lateral motion at the north end which neighbors Yanshan unit and a compressive motion at the south end. It should be noted that the errors given in the paper are obtained based on the divergence among the displacements of the sites in the unit, rather than the value calculated from the displacement error of the sites. The analyzed results indicate that: ① Shanxi tectonic zone and Yan-Ji transition zone are the major tectonic active zones to show the frame and magnitude of interior relative movement in North China area, and others are the secondary tectonic active zones; ② The complete horizontal deformation in the North China area is not homo
基金supported by Fundamental Research Funds for the Central Universities(No.2019RC006)National Natural Science Foundation of China(No.52077004)。
文摘To completely eliminate the time delays caused by phasor data compressions for real-time synchrophasor applications,a real-time synchrophasor data compression(RSDC)is proposed in this paper.The two-way rotation characteristic and elliptical trajectory of dynamic synchrophasors are introduced first to enhance the compressions along with a fast solving method for elliptical trajectory fitting equations.The RSDC for phasor data compression and reconstruction is then proposed by combining the interpolation and extrapolation compressions.The proposed RSDC is verified by both the actual phasor measurement data recorded in a two-phase short-circuit incident and a subsynchronous oscillation incident,and the synthetic dynamic synchrophasors.It is also compared with two previous real-time phasor data compression techniques,i.e.,phasor swing door trending(PSDT)and exception and swing door trending(SDT)data compression(ESDC).The verification results demonstrate that RSDC can achieve significantly higher compression ratios for offline applications with the interpolation and the zero-delay phasor data compression with the extrapolation for real-time applications simultaneously.