期刊文献+
共找到93篇文章
< 1 2 5 >
每页显示 20 50 100
Comparison of visual outcomes with implantation of trifocal versus bifocal intraocular lens after phacoemulsification: a Meta-analysis 被引量:10
1
作者 Juan-Juan Yang Qiu-Ping Liu +1 位作者 Jing-Ming Li Li Qin 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第3期484-492,共9页
AIM: To compare a trifocal intraocular lens (IOL) and a bifocal IOL implantation in improving visual function after cataract surgery. METHODS: Eligible literatures were systematically searched through EMBASE and P... AIM: To compare a trifocal intraocular lens (IOL) and a bifocal IOL implantation in improving visual function after cataract surgery. METHODS: Eligible literatures were systematically searched through EMBASE and PubMed databases. The inclusion criteria were prospective comparative clinical trials on cataract surgery comparing trifocal IOL with bifocal IOL implantation that assessed visual acuity, contrast sensitivity and subjective vision quality. The effects were computed as standardized mean differences and pooled using fixed-effect or random-effect models. RESULTS: Four prospective randomized controlled trials (RCTs) and five cohorts provided data were included by a systematic review, comprising 265 eyes implanted with trifocal IOLs and 264 eyes implanted with bifocal IOLs. Monocular distance visual acuity (VA) showed a statistically significant but small difference that favored trifocal IOLs (MD=.0.06; 95%CI, -0.10 to -0.02; Z=2.90, P=0.004 for uncorrected distance VA, and MD- -0.02; 95%CI, -0.03 to .0.00; Z=2.02, P=0.04 for corrected distance VA), but the data did not suggest that the effect of trifocal IOL implantation would clinically outperform bifocal IOL implantation. There was no significant difference in monocular near VA (MD=.0.01; 95%CI, -0.07 to 0.04; Z=0.42, P=-0.68 for distance-corrected near VA, and MD=-0.01; 95%CI, -0.06 to 0.03; Z=0.55, P=0.58 for corrected near VA) or refraction between two groups. Contrast sensitivity and subjective visual quality had no conclusive results. CONCLUSION: All results indicate that trifocal IOL and bifocal IOL had similar levels of monocular distance and near VA. 展开更多
关键词 trifocal intraocular lens bifocal intraocularlens visual function META-ANALYSIS
下载PDF
三节段截骨骨搬运治疗创伤后胫骨骨髓炎一例报道并文献复习 被引量:11
2
作者 伊力扎提·伊力哈木 亚穆罕默德·阿力克 +2 位作者 阿里木江·阿不来提 阿依古丽·喀斯木 艾合买提江·玉素甫 《中华显微外科杂志》 CSCD 北大核心 2017年第6期555-559,共5页
目的探讨外固定架进行3节段截骨骨搬运手术减少创伤后骨髓炎患者治疗周期的可能性。方法2017年2月收治左侧胫骨骨髓炎合并软组织缺损患者1例。通过术前计算机设计、预手术操作后.利用Orthofix单臂外固定架进行3处截骨骨搬运的手术方案... 目的探讨外固定架进行3节段截骨骨搬运手术减少创伤后骨髓炎患者治疗周期的可能性。方法2017年2月收治左侧胫骨骨髓炎合并软组织缺损患者1例。通过术前计算机设计、预手术操作后.利用Orthofix单臂外固定架进行3处截骨骨搬运的手术方案。在分析该病例资料的基础上。回顾相关文献。结果在左小腿皮肤软组织愈合良好的同时.该术式在45d时间里完成了左胫骨12.5cm骨缺损的矿化.约为传统单节段骨搬运时间的1/3.并明显缩短了新生骨的矿化时间。后因随访时发现患者无意中操作不当.骨搬运的断端出现约5mm间隙,骨搬运术后第140天随访.间隙消失,已开始正常行走。结论本研究可能为骨髓炎骨缺损的治疗提供了一种可行的方法。可以明显缩短创伤后骨髓炎的治疗时间。从而降低治疗并发症。 展开更多
关键词 创伤后骨髓炎 外固定架 骨缺损 三节段骨搬运技术
原文传递
Residual Astigmatism Threshold and Patient Satisfaction with Bifocal, Trifocal and Extended Range of Vision Intraocular Lenses (IOLs) 被引量:8
3
作者 Francesco Carones 《Open Journal of Ophthalmology》 2017年第1期1-7,共7页
Purpose: To compare the impact of induced astigmatism with four different types of multifocal intraocular lenses (MIOLs). Method: Prospective, comparative, interventional, mono-centered study, including 80 eyes of pat... Purpose: To compare the impact of induced astigmatism with four different types of multifocal intraocular lenses (MIOLs). Method: Prospective, comparative, interventional, mono-centered study, including 80 eyes of patients with implantation of four different MIOLs: AcrySof ReSTOR +2.5 D (20 eyes), AcrySof ReSTOR +3.0 D (20 eyes), AcrySof Panoptix (20 eyes) (Alcon Laboratories, Inc., Fort Worth, TX, USA), and Tecnis Symfony ZRX00 (Abbott Medical Optics, Santa Ana, USA) (20 eyes). Patients were followed up for 3 months after surgery. Major parameters were uncorrected (UDVA) and corrected (CDVA) distance visual acuity, subjective refraction and patient satisfaction. Results: Differences between IOLs with regard to the impact of the cylinder sign and axis on visual acuity and patient satisfaction were not significant. With mild added negative cylinder, AcrySof ReSTOR +2.5 D and Tecnis Symfony IOLs maintained the baseline visual acuity, while it was mildly reduced with AcrySof ReSTOR +3.0 D and Panoptix IOLs. With moderate induced cylinder, the Tecnis Symfony IOL maintained good visual acuity and patient associated satisfaction. Panoptix IOL was the IOL most affected by the induced astigmatism with regard to dissatisfaction and visual acuity. The highest tolerance to the astigmatic distortion and blurriness induced with a -1.50 D cylinder was obtained with the Tecnis Symfony IOL. Tecnis Symfony IOL showed less dissatisfaction and less reduction of visual acuity than the other MIOLs. Conclusion: Simulated residual cylinders after the implantation of the Tecnis Symfony IOL up to 1.0 D have a very mild and not clinically relevant impact on visual acuity or patient satisfaction. The ERV IOL showed a better tolerance to unexpected postoperative residual errors than diffractive bifocal and trifocal IOLs. 展开更多
关键词 MULTIFOCAL IOL ASTIGMATISM Tolerance Bifocal trifocal Extended Range of VISION TECNIS Symfony Panoptix ACRYSOF RESTOR
下载PDF
Postoperative visual performance with a bifocal and trifocal diffractive intraocular lens during a 1-year follow-up 被引量:6
4
作者 Peter Mojzis Lucia Kukuckova +2 位作者 Katarina Majerova Peter Ziak David P.Pi?ero 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第10期1528-1533,共6页
AIM:To evaluate and compare the clinical outcomes with a diffractive bifocal and trifocal intraocular lens(IOL)during a 12-month follow-up.METHODS:Prospective comparative study including75 eyes of 38 patients(44-... AIM:To evaluate and compare the clinical outcomes with a diffractive bifocal and trifocal intraocular lens(IOL)during a 12-month follow-up.METHODS:Prospective comparative study including75 eyes of 38 patients(44-70y)undergoing uneventful cataract surgery.Each patient was randomly assigned to one type of IOL,bifocal(35 eyes)or trifocal(40 eyes).Visual,refractive,and contrast sensitivity changes were evaluated in a 12-month follow-up.The binocular defocus curve was also measured at 12mo postoperatively.RESULTS:No statistically significant differences between groups were found in postoperative uncorrected and corrected distance visual acuities(P≥0.276).Postoperative corrected near visual acuity(33 cm)was significantly better in the trifocal group during all follow-up(P≤0.004)as well as 6-month uncorrected near(P=0.008)and distancecorrected near visual acuities(P=0.016)(33/40 cm).Significantly better uncorrected intermediate and distance corrected-intermediate visual acuity were found during all follow-up in the trifocal group(P〈0.001),which was consistent with differences among groups in binocular defocus curve.Differences among groups in contrast sensitivity were minimal,being only significant at 6 months for some low to medium spatial frequencies(P≤0.006).CONCLUSION:Bifocal and trifocal diffractive IOLs are able to provide an effective visual restoration which is maintained during a 12-month follow-up,with a clear benefit of the trifocal IOL for the intermediate vision. 展开更多
关键词 trifocal intraocular lens bifocal intraocular lens defocus curve contrast sensitivity cataract surgery
下载PDF
OPD-ScanⅢ型像差分析仪评估高度近视合并白内障患者植入三焦点IOL术后视觉质量 被引量:8
5
作者 赵抒羽 何锦贤 +1 位作者 吴燕纯 梁先军 《国际眼科杂志》 CAS 北大核心 2022年第2期318-321,共4页
目的:应用OPD-ScanⅢ型像差分析仪评估高度近视合并白内障患者植入三焦点人工晶状体(IOL)术后视觉质量。方法:选取2018-06/2020-12在佛山爱尔眼科医院接受飞秒激光辅助白内障超声乳化手术联合植入三焦点IOL的高度近视白内障患者32例38眼... 目的:应用OPD-ScanⅢ型像差分析仪评估高度近视合并白内障患者植入三焦点人工晶状体(IOL)术后视觉质量。方法:选取2018-06/2020-12在佛山爱尔眼科医院接受飞秒激光辅助白内障超声乳化手术联合植入三焦点IOL的高度近视白内障患者32例38眼,比较术前,术后1wk,3mo裸眼远视力(UCDVA)、中距离视力(UCIVA)、近距离视力(UCNVA);术前,术后1wk,3mo进行OPD-ScanⅢ型像差分析仪检查。结果:术前,术后1wk,3mo UCDVA、UCIVA、UCNVA比较均有差异(P<0.05),术后3mo人工晶状体偏心距为0.12(0.08~0.15)mm,轴位为(212.68±90.45)°。术前,术后1wk,3mo球差比较有差异(P<0.05)。术前,术后1wk,3mo斯特列尔比(SR)、调制传递函数(MTF)曲线中4mm面积比(AR)比较均有差异(P<0.001)。术后1wk,3mo SR比术前提升,术后1wk,3mo AR比术前提升(均P<0.001)。术后3mo SR与球差、三叶草呈负相关(rs=-0.420、-0.418,均P<0.01);术后3mo AR与三叶草呈负相关(rs=-0.400,P<0.05)。结论:高度近视合并白内障患者植入三焦点IOL术后全程视力提高,OPD-ScanⅢ型像差分析仪结果显示术后IOL居中性良好,视觉质量良好。 展开更多
关键词 三焦点 人工晶状体(IOL) 高度近视 白内障 OPD-ScanⅢ型像差分析仪
下载PDF
老视矫正型人工晶状体原理及临床应用新进展 被引量:8
6
作者 杨琉舒 耿宇 +1 位作者 赵剑峰 李燕 《国际眼科杂志》 CAS 2017年第5期876-880,共5页
白内障手术已从简单的复明手术发展成为更具挑战的屈光手术,手术需求者希望通过手术提高视力并摘掉眼镜,单焦点人工晶状体虽能解决患者视远问题却无法解决脱镜问题,由此老视矫正型人工晶状体应运而生。在双焦点人工晶状体的基础上,目前... 白内障手术已从简单的复明手术发展成为更具挑战的屈光手术,手术需求者希望通过手术提高视力并摘掉眼镜,单焦点人工晶状体虽能解决患者视远问题却无法解决脱镜问题,由此老视矫正型人工晶状体应运而生。在双焦点人工晶状体的基础上,目前市场上新产生的几款老视矫正型人工晶状体成为了热门。本文将综述目前临床应用广泛的几款老视矫正型人工晶状体的设计原理及临床应用效果。 展开更多
关键词 老视矫正 三焦点 连续视程 人工晶状体 白内障 视觉质量
下载PDF
三焦点人工晶状体术后早期临床观察 被引量:8
7
作者 周星延 王静 +3 位作者 赵江月 丁倩 彭程 张劲松 《中华眼视光学与视觉科学杂志》 CAS CSCD 2018年第6期360-364,共5页
目的:比较三焦点人工晶状体(IOL)与单焦点IOL植入术后早期的视力情况、视觉质量及患者满意度。方法:前瞻性临床研究。选取2016年4-7月就诊于中国医科大学附属第四医院眼科确诊为白内障欲行手术治疗的患者44例(50眼),植入三焦点IOL为实验... 目的:比较三焦点人工晶状体(IOL)与单焦点IOL植入术后早期的视力情况、视觉质量及患者满意度。方法:前瞻性临床研究。选取2016年4-7月就诊于中国医科大学附属第四医院眼科确诊为白内障欲行手术治疗的患者44例(50眼),植入三焦点IOL为实验组(22例,25眼),植入单焦点IOL为对照组(22例,25眼)。随访至术后3个月,测试单眼裸眼远中近视力(LogMAR)、离焦曲线、主观散射光、客观散射指数(OSI)、调制传递函数截止频率(MTFcutoff)、斯特列尔比(SR)、像差,并发放调查问卷统计患者满意度、脱镜率以及光晕发生率。采用配对t检验、Wilcoxon符号秩检验及χ2检验进行数据分析。结果:术后3个月,2组间远视力差异无统计学意义,中、近视力方面,实验组(0.12±0.11、0.17±0.11)优于对照组(0.28±0.08、0.47±0.16)(t=-5.912、-8.504,均P<0.001);实验组(2.02±0.93)的OSI高于对照组(1.13±0.31)(t=-3.311,P=0.001);2组间MTFcutoff、SR、主观散射光以及像差的差异均无统计学意义;实验组在满意度和脱镜率方面优于对照组(χ2=4.50,P=0.034;χ2=30.65,P<0.001),光晕发生率在2组间差异无统计学意义。结论:三焦点IOL植入术后,患者拥有良好的远、中、近全程视力及视觉质量。 展开更多
关键词 人工晶状体 三焦点 单焦点 视觉质量
原文传递
三焦点衍射型人工晶状体植入术后视觉质量临床评价 被引量:6
8
作者 彭程 周星延 +1 位作者 赵江月 张劲松 《中国医科大学学报》 CAS CSCD 北大核心 2019年第5期385-389,共5页
目的比较三焦点衍射型人工晶状体(IOL)植入术后视力、屈光状态、视觉质量及满意度。方法选取在我院植入三焦点衍射型IOL (AT LISA tri839MP,Carl ZEISS)的患者40例(50只眼)。于术后1周、1个月、3个月时测试单眼裸眼远视力(UDVA)、裸眼... 目的比较三焦点衍射型人工晶状体(IOL)植入术后视力、屈光状态、视觉质量及满意度。方法选取在我院植入三焦点衍射型IOL (AT LISA tri839MP,Carl ZEISS)的患者40例(50只眼)。于术后1周、1个月、3个月时测试单眼裸眼远视力(UDVA)、裸眼中距离视力(UIVA)、裸眼近距离视力(UNVA)、离焦曲线、客观散射指数(OSI)、调制传递函数截止频率(MTF cutoff)、斯特列尔比(SR)、眼内散射光、高阶像差,采用主观调查问卷统计患者整体满意度、光晕发生率及脱镜率。应用重复测量的方差分析进行数据分析。结果患者术后1周、1个月、3个月的等效球镜均在目标度数±0.5 D范围内,与术前比较差异均有统计学意义(均P <0.001)。术后1周、1个月、3个月的UDVA、UIVA、UNVA均有明显提高,与术前比较差异均有统计学意义(均P <0.001),且均可到达0.3 logMAR或以上。术后3个月时,离焦曲线1.0 D~-2.5 D范围内,视力处于较高值,均>0.2 logMAR,且变化平缓。患者术后1周、1个月、3个月的log[s]与术前比较差异无统计学意义(F=0.460,P=0.710)。术后1周、1个月、3个月的OSI值较术前下降,且差异有统计学意义(F=16.813,P <0.001),术后1周、1个月、3个月的MTF cutoff、SR值较术前增大,差异有统计学意义(F=-1.469,P <0.001;F=3.405,P=0.019)。术后1周、1个月、3个月的球差较术前下降,且差异有统计学意义(F=18.913,P <0.001);术后各时间点的高阶像差、慧差、三叶草差、与术前比较,差异均无统计学意义(F=1.715 9,P=0.165;F=0.185 8,P=0.906;F=0.081,P=0.970;F=0.523,P=0.667)。术后整体满意度92%(46/50),日常生活舒适度94%(47/50),光晕发生率24%(12/25),脱镜率98%(49/50)。结论三焦点IOL可提供良好的全程视力,且患者主观满意度较高,术后视觉质量较好。 展开更多
关键词 三焦点 人工晶状体 视觉质量 离焦曲线 视敏度
下载PDF
三焦点与单焦点人工晶状体植入术后1年视觉质量比较 被引量:5
9
作者 秦勤 刘军 +4 位作者 陈晖 李一壮 鲍连云 何自芳 解正高 《中华实验眼科杂志》 CAS CSCD 北大核心 2022年第5期454-460,共7页
目的比较三焦点与单焦点人工晶状体(IOL)植入术后1年视觉质量。方法采用队列研究设计,纳入2017年5月至2018年6月在南京大学医学院附属鼓楼医院行超声乳化白内障摘出联合IOL植入术的年龄相关性白内障患者41例41眼,根据患者意愿将其分为... 目的比较三焦点与单焦点人工晶状体(IOL)植入术后1年视觉质量。方法采用队列研究设计,纳入2017年5月至2018年6月在南京大学医学院附属鼓楼医院行超声乳化白内障摘出联合IOL植入术的年龄相关性白内障患者41例41眼,根据患者意愿将其分为三焦点IOL组20例20眼和单焦点IOL组21例21眼,分别植入AT LISA tri 839MP三焦点IOL和603P单焦点IOL。术后随访1年,检测2个组患者术后1年裸眼远距离视力(UCDVA)、裸眼中距离视力(UCIVA)、裸眼近距离视力(UCNVA)、最佳矫正远视力(BCDVA)、远视力矫正下的中距离视力(DCIVA)和远视力矫正下的近距离视力(DCNVA);采用OQASⅡ检测患者点扩散函数(PSF)、调制传递函数(MTF)截止频率、斯特尔比率(SR),以及对比度分别为100%、20%、9%时的OQASⅡ值(OV 100%、OV 20%、OV 9%)及客观散射指数(OSI);采用iTrace视功能分析仪评估患者的波前像差,包括全眼总像差(TA)、总高阶像差(tHOAs)、球差、彗差、三叶草像差、总低阶像差(tLOAs)、离焦、散光,所有像差值用均方根表示;采用综合验光仪检测2个组患者术眼不同调节范围内的视力,并以高于0.5 LogMAR视力绘制离焦曲线图;采用裂隙灯显微镜观察并以Sellman法量化分析2个组患者IOL区域内后囊膜混浊(PCO)发生程度;采用视功能指数量表(VF-14)对视功能进行评分。结果术后1年,三焦点IOL组患者UCIVA、UCNVA、DCIVA和DCNVA明显优于单焦点IOL组,差异均有统计学意义(均P<0.001)。OQASⅡ视觉质量指标显示,三焦点IOL组患者MTF截止频率、SR、OV 100%及OSI值明显高于单焦点IOL组,差异均有统计学意义(均P<0.001)。2个组患者各波前像差比较,差异均无统计学意义(均P>0.05)。离焦曲线显示,单焦点IOL组组患者在-1.0、-1.5、-2.0、-2.5、-3.0、-3.5 D时(即相当于1 m、66 cm、50 cm、40 cm、33 cm、29 cm)的LogMAR视力明显高于三焦点IOL组,差异均有统计学意义(均P<0.05)。三焦点IOL组 展开更多
关键词 白内障 手术 人工晶状体 三焦点 人工晶状体 单焦点 视觉质量
下载PDF
Effectivity and safety of trifocal intraocular lenses and capsular tension rings implantation for cataract patients with axial high myopia
10
作者 Shan Hua Qiu-Xia Xie +1 位作者 Hu Wang Jing-Xiang Zhong 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期499-508,共10页
●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical tria... ●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663) 展开更多
关键词 trifocal intraocular lenses capsular tension ring axial high myopia CATARACT visual quality
下载PDF
Early outcomes of vision and objective visual quality analysis after cataract surgery with trifocal intraocular lens implantation 被引量:3
11
作者 Mei-Fang Chu Na Hui +4 位作者 Cong-Yi Wang Lei Yu Bo Ma Yan Li Cheng Pei 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第10期1575-1581,共7页
AIM: To investigate the early outcomes of vision, objective visual quality and their correlation after cataract surgery with trifocal intraocular lens implantation.METHODS: The visual examination and objective visual ... AIM: To investigate the early outcomes of vision, objective visual quality and their correlation after cataract surgery with trifocal intraocular lens implantation.METHODS: The visual examination and objective visual quality analysis using Optical Quality Analysis System(OQAS) at 1 mo and 3 mo, and defocus curve examination at 3 mo were performed in 20 patients(27 eyes) after phacoemulsification combined with trifocal intraocular lens implantation surgery.RESULTS: The uncorrected distant(UD), intermediate and near visual acuity(VA) were significantly improved after surgery(P<0.001). UDVA at 1 mo after the surgery was slightly better than that after 3 mo(P=0.026). The defocus curve after 3 mo indicated that the peak of distant vision was close to 0 logMAR, and UDVA was lower than 0.3 logMAR in the range of-1.5 D to-3.0 D. The modulation transfer function(MTF) cutoff frequency, strehl ratio(SR), Optical Quality Analysis System values(OVs), includes OV100, OV20 and OV9 after the surgery were significantly better than before surgery(P<0.001), but the objective scattering index(OSI) was significantly decreased(P<0.001). UDVA at 3 mo after the surgery had correlations with MTF cutoff, OSI, OV100 and OV20(r=-0.400, 0.431,-0.437,-0.411, P=0.039, 0.025, 0.023, 0.033). The uncorrected intermediate VA after 3 mo of the surgery had correlations with OSI and OV100(r=0.478,-0.411, P=0.012, 0.033). CONCLUSION: Trifocal intraocular lens implantation can provide good distant, intermediate and near VA, and the vision shows a well correlation with objective visual quality during early surgery. 展开更多
关键词 visual quality trifocal INTRAOCULAR LENS VISION correlation
下载PDF
基于“有诸内者,必形诸外”探析黄褐斑从三焦辨治 被引量:5
12
作者 冯杨洋 许鹏光 《四川中医》 2020年第10期48-52,共5页
“有诸内者必形诸外”,黄褐斑虽为皮肤色素性疾病,发于颜面却与机体内在阴阳失衡、脏腑失调、三焦不通、经络不畅、气血不能上荣于面有关。故而临床治疗黄褐斑不应拘泥于局部斑片所在部位、色泽、范围等表象,应从中医整体观出发,重视人... “有诸内者必形诸外”,黄褐斑虽为皮肤色素性疾病,发于颜面却与机体内在阴阳失衡、脏腑失调、三焦不通、经络不畅、气血不能上荣于面有关。故而临床治疗黄褐斑不应拘泥于局部斑片所在部位、色泽、范围等表象,应从中医整体观出发,重视人体为一个系统的有机整体,本于辨证型之不同,分证型而论治。文章简要梳理了三焦学说及主持诸气运行津液的功能,从上、中、下三焦分别论述黄褐斑发病病因以及临床方药针刺治疗。通调三焦,充足营血则五脏六腑得以滋养、四肢百骸得以濡润,故而也是治疗黄褐斑的基本原则,三焦不通则斑生,三焦通则斑无以生。 展开更多
关键词 黄褐斑 通调三焦 黑素细胞
下载PDF
A More Natural Way of Seeing: Visual Performance of Three Presbyopia Correcting Intraocular Lenses 被引量:2
13
作者 Amir Hamid Arif Sokwala 《Open Journal of Ophthalmology》 2016年第3期176-183,共9页
Purpose: To compare the visual and refractive outcomes, patient satisfaction and spectacle independence between three novel designs of diffractive IOLs. Method: Prospective study including 150 patients with implantati... Purpose: To compare the visual and refractive outcomes, patient satisfaction and spectacle independence between three novel designs of diffractive IOLs. Method: Prospective study including 150 patients with implantation of three IOLs: trifocal diffractive IOL AT LISA tri 839 MP (ATLISA, n = 50), trifocal diffractive IOL PhysIOL FineVision (FineVision, n = 50) and the extended range of vision IOL Tecnis Symfony ZRX00 (Symfony, n = 50). Patients were followed up for 6 months after surgery. Major parameters were monocular and binocular uncorrected (UDVA) and corrected (CDVA) distance, uncorrected (UIVA) and distance corrected (DCIVA) intermediate (80 cm), and uncorrected (UNVA) and distance corrected (DCNVA) near (40 cm) visual acuities (UNVA), contrast sensitivity (CS), defocus curve as well as patient satisfaction and spectacle use. Results: Mean postoperative decimal UDVA was 1.01 for Symfony, 0.96 for ATLISA and 0.95 for the FineVision IOL. Postoperative UIVA was 0.95 with Symfony, 0.72 with ATLISA and 0.85 with the FineVision IOL. Postoperative UNVA was 0.96 with the FineVision, 0.72 with the ATLISA and 0.63 with the Symfony IOL. The Symfony defocus curve showed the smoothest profile. Mean mesopic CS was 0.84 log units with the Symfony, 0.83 with the ATLISA (0.83) and 0.65 with the FineVision IOL. Mean photopic CS with the Symfony, ATLISA and FineVision was 1.05, 0.85 and 0.69 log units, respectively. Twenty percent of the patients with the ATLISA and FineVision IOLs and 5.6% of the Symfony patients reported halos and glare as troublesome or disabling. Reading glasses were frequently used by 5.6% of the Symfony patients. All patients with the trifocal IOLs reported to be spectacle-free for any distance. Conclusion: All 3 IOLs produce excellent results with high levels of spectacle independence. The Symfony produces better levels of distance and intermediate visual acuity, whereas the trifocal IOLs produced better near vision. Higher frequency of dysphotopsia was seen with the trifocal IOLs. 展开更多
关键词 Extended Range of Vision Tecnis Symfony trifocal Defocus Curve Visual Outcome
下载PDF
Visual quality after implantation of trifocal intraocular lenses in highly myopic eyes with different axial lengths 被引量:4
14
作者 Hui Liu Fang-Fang Li +1 位作者 Hai-Jun Xia Jin Zhou 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第3期371-377,共7页
AIM:To analyze postoperative clinical results after implantation of trifocal intraocular lenses(IOLs)in highly myopic eyes with different axial lengths(ALs).METHODS:This retrospective study describes 61 eyes of 44 pat... AIM:To analyze postoperative clinical results after implantation of trifocal intraocular lenses(IOLs)in highly myopic eyes with different axial lengths(ALs).METHODS:This retrospective study describes 61 eyes of 44 patients that were implanted with trifocal diffractive IOLs(AT LISA tri 839 MP).Twenty-one eyes(15 patients)were included in the AL<26 mm group,19 eyes(13 patients)in the AL≥26 mm and<28 mm group,and 21 eyes(16 patients)in the AL≥28 mm group.Postoperative outcomes,including corrected and uncorrected distance visual acuity(UDVA),intermediate and near visual acuity at 167 cd/m2 luminance,depth of focus at 85 cd/m2 luminance,and objective optical quality parameters assessed using the Optical Quality Analysis System(OQAS),were compared among the groups at 3 mo.RESULTS:There were no significant differences in the mean UDVA,uncorrected intermediate visual acuity,uncorrected near visual acuity,corrected distance visual acuity,distance-corrected intermediate visual acuity,and distance-corrected near visual acuity(DCNVA)among the three groups(P>0.05).Better near and intermediate visual acuity(from-1.5 D to-3.0 D)were noted on the defocus curve of the AL<26 mm group(P<0.01 vs AL≥28 mm group).Significantly higher objective scatter index(OSI)values and lower modulation transfer function(MTF)cut-off values,Strehl ratio(SR),and OQAS values(OVs)were observed in the AL≥28 mm group(P<0.01 vs AL<26 mm group).All OQAS parameters had statistically significant correlations with DCNVA and visual acuity at the vergence of-2.5 D(P<0.05 to P<0.01).CONCLUSION:Implantation of trifocal IOLs provides good short-term visual and refractive outcomes in highly myopic eyes with different ALs.However,the near vision decreases in the extremely myopic eyes at lower luminance,which is associated with the lower objective optical quality in these eyes. 展开更多
关键词 CATARACT trifocal IOL OQAS high myopia
下载PDF
Visual and refractive outcomes following implantation of a new trifocal intraocular lens 被引量:1
15
作者 Michael Lawless Chris Hodge +5 位作者 Joe Reich Lewis Levitz Uday K.Bhatt Colm McAlinden Kate Roberts Timothy V.Roberts 《Eye and Vision》 SCIE 2017年第1期42-47,共6页
Background:Independence from all optical aids,and freedom from unwanted symptoms,following cataract and lens surgery remains the ultimate goal of both patient and surgeon.The development of trifocal IOL technology pro... Background:Independence from all optical aids,and freedom from unwanted symptoms,following cataract and lens surgery remains the ultimate goal of both patient and surgeon.The development of trifocal IOL technology provides an ever-increasing range of options.The purpose of our study is to understand the predictability,safety and efficacy of a new trifocal intraocular lens(IOL)following cataract or refractive lens exchange(RLE)surgery.Methods:This was a retrospective consecutive case series of patients undergoing cataract extraction or RLE followed by implantation of the Alcon IQ Panoptix IOL.Pre and postoperative refractive and visual parameters were recorded and evaluated.As the cohort followed a normal distribution,standard parametric tests were used.Paired t-test was used to compare the difference between target and postoperative refractive errors.The incidence of intraoperative and postoperative complications was also reported.Results:The IOL was implanted in 66 eyes of 33 patients.Mean postoperative spherical equivalent(SE)refraction was-0.08±0.25 dioptres(D).This was not significantly different from the target refraction(p=0.841).Sixty-five percent of patients were within±0.25 D of the target SE refraction with 100%within±0.50 D of intended correction.Mean postoperative uncorrected distance visual acuity(UDVA)was 0.01±0.10 LogMAR.All patients achieved an unaided distance acuity of 20/40 or better postoperatively.Binocularly,100%saw 0.20 LogMAR or better at near without correction and 88.9%achieved this level for uncorrected intermediate visual acuity.No intraoperative complications were noted.Five patients complained of moderate haloes in the early postoperative period.Conclusion:The AcrySof IQ Panoptix IOL provides functional uncorrected visual acuity at distance,intermediate and near positions.Our results remain equivalent with existing trifocal IOL outcomes and provide surgeons with a further IOL alternative for the patient motivated to obtain true spectacle independence.Surgeons should consider indi 展开更多
关键词 trifocal trifocal IOL CATARACT Refractive lens exchange
原文传递
Trifocal distraction osteogenesis for reconstruction of skull defect 被引量:1
16
作者 Ke Ke Hai-Song Xu Zhi-Hong Fan 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2013年第8期644-648,共5页
Objective: To apply trifocal distraction osteogenesis in canine model of skull segmental defects and to provide reference for clinical treatment. Methods: Six labrador dogs were selected in this study and divided into... Objective: To apply trifocal distraction osteogenesis in canine model of skull segmental defects and to provide reference for clinical treatment. Methods: Six labrador dogs were selected in this study and divided into observation group and control group randomly. Each group contained 3 dogs. Skull segmental defects models were established by surgery, and dogs in bservation group received trifocal distraction osteogenesis treatment. Bone density was observed and compared between two groups during treatment. Results: There were no significant difference in bone density between two groups on th 1st day ( P>0.05). The bone density of observation group on the 30th day, and 60th day were higher than that of control group ( P<0.01). Conclusions: Trifocal distraction osteogenesis has significant clinical effect, and it would be widely used in clinical treatment. 展开更多
关键词 trifocal DISTRACTION OSTEOGENESIS SKULL SEGMENTAL DEFECTS DOG
下载PDF
多焦点人工晶状体的临床应用进展 被引量:3
17
作者 毛一 张凤妍 邵敬芝 《中华眼外伤职业眼病杂志》 2018年第5期397-400,共4页
近年来,多焦点人工晶状体如区域折射型多焦点人工晶状体、连续视程人工晶状体、三焦点人工晶状体等相继问世,大大改善了白内障患者术后的中视力,更好地提高了患者术后对比敏感度,降低眩光和光晕等不适。现就新型多焦点人工晶状体的... 近年来,多焦点人工晶状体如区域折射型多焦点人工晶状体、连续视程人工晶状体、三焦点人工晶状体等相继问世,大大改善了白内障患者术后的中视力,更好地提高了患者术后对比敏感度,降低眩光和光晕等不适。现就新型多焦点人工晶状体的设计原理及临床应用进展进行综述。 展开更多
关键词 白内障 晶状体 人工 多焦点 三焦点 区域折射 连续视程
原文传递
三焦点人工晶状体与双焦点人工晶状体植入术后临床观察 被引量:2
18
作者 杨兴华 《中国实用医药》 2019年第5期42-44,共3页
目的比较三焦点人工晶状体(IOL)与双焦点IOL植入术后早期视力情况、视觉质量及患者满意度。方法 62例(75眼)行白内障超声乳化吸除联合IOL植入术的白内障患者,根据治疗方法不同分为三焦点IOL组(采用三焦点IOL植入术, 20例25眼)和双焦点IO... 目的比较三焦点人工晶状体(IOL)与双焦点IOL植入术后早期视力情况、视觉质量及患者满意度。方法 62例(75眼)行白内障超声乳化吸除联合IOL植入术的白内障患者,根据治疗方法不同分为三焦点IOL组(采用三焦点IOL植入术, 20例25眼)和双焦点IOL组(采用双焦点IOL植入术, 42例, 50眼)。术后随访3个月,测量两组患者远、中、近视力(LogMAR),离焦曲线,调查问卷患者满意度,并进行组间比较。结果三焦点IOL组远、中、近视力分别为(0.04±0.05)、(0.10±0.08)、(0.07±0.08),双焦点IOL组远、中、近视力分别为(0.06±0.06)、(0.36±0.12)、(0.09±0.07),两组患者远、近视力比较差异无统计学意义(t=-1.43、-1.11, P>0.05);三焦点IOL组患者中视力优于双焦点IOL组,差异具有统计学意义(t=-9.78, P<0.05)。两组离焦曲线在0 D处均存在最高峰,三焦点IOL组的离焦曲线中在-1.0~2.5 D平缓稳定于高位。通过问卷调查,三焦点IOL组和双焦点IOL组患者分别有2例和4例出现光晕,但不影响日常生活。三焦点IOL组满意度20%(5/25)明显高于双焦点IOL组的4%(2/50),差异具有统计学意义(P<0.05)。结论三焦点IOL与双焦点IOL植入术后均可获得较好的远近视力,三焦点IOL植入术后的中视力优于双焦点IOL植入,三焦点IOL植入术与双焦点IOL植入术视觉质量相当。 展开更多
关键词 人工晶状体 三焦点 双焦点 视觉质量
下载PDF
Comparative analysis of visual quality between unilateral implantation of a trifocal intraocular lens and a rotationally asymmetric refractive multifocal intraocular lens 被引量:1
19
作者 Na Hui Mei-Fang Chu +3 位作者 Yan Li Cong-Yi Wang Lei Yu Bo Ma 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第9期1460-1467,共8页
·AIM:To compare visual quality after unilateral cataract surgery with implantation of trifocal intraocular lens(IOL)and asymmetric refractive multifocal IOL.·METHODS:The prospective nonrandom,comparative stu... ·AIM:To compare visual quality after unilateral cataract surgery with implantation of trifocal intraocular lens(IOL)and asymmetric refractive multifocal IOL.·METHODS:The prospective nonrandom,comparative study consisted of 60 eyes of 60 patients suffering unilateral cataract surgery with implantation of two different IOLs:AT LISA tri 839 MP(30 eyes;Carl Zeiss Meditec,Germany)and LS-313 MF30(30 eyes;Oculentis GmbH,Germany).Visual acuity,refractive outcome,contrast sensitivity,defocus curves,quality of vision,and optical phenomena were evaluated at3 mo postoperatively.·RESULTS:There were no statistical differences between groups in uncorrected distance visual acuity(P=0.13)and uncorrected near visual acuity(P=0.54).In contrast,uncorrected intermediate visual acuity was better in trifocal group compared to the refractive multifocal group(P=0.02).No significant statistical between-group difference was detected in cylinder(P=0.43).Compared to trifocal group,spherical refraction and spherical equivalent in refractive multi focal group were more myopic(P<0.01).Under photopic conditions,no significant statistical differences were found between groups in contrast sensitivity at 3 and 6 cycles per degree(cpd).The refractive multifocal group performed better at 12 and 18 cpd than the trifocal group(P=0.01,P=0.034,respectively).The questionnaires of quality of vision and optical phenomena showed no differences between groups.·CONCLUSION:Trifocal IOL is superior to refractive multifocal IOL in intermediate visual acuity.Rotationally asymmetric refractive multifocal IOL is more myopic in automated refraction and significantly better for the photopic contrast sensitivity at high frequency. 展开更多
关键词 trifocal intraocular lens rotationally asymmetric multifocal intraocular lens visual quality contrast sensitivity
下载PDF
Full-vision maintenance in extra-high myopia from implantable collamer lens to trifocal intraocular lens implantation 被引量:2
20
作者 Shu-Yang Chen Chen Xie +1 位作者 Yang Wang Ye Shen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第7期1239-1242,共4页
Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patien... Dear Editor,I am Dr.Ye Shen from the Department of Ophthalmology,the First Affiliated Hospital,College of Medicine,Zhejiang University,Hangzhou,China.I write to share my experience of full-vision maintenance in patient with extrahigh myopia from implantable collamer lens (ICL) to trifocal intraocular lens (IOL) implantation. 展开更多
关键词 ICL IOL Full-vision maintenance in extra-high myopia from implantable collamer lens to trifocal intraocular lens implantation
下载PDF
上一页 1 2 5 下一页 到第
使用帮助 返回顶部