对张力腿平台(tension leg platform,TLP)在不同系泊失效条件下的动态响应进行分析,采用全耦合数值工具ANSYS/AQWA建立非线性平台-筋腱模型,并提出一种模拟筋腱失效的方法。主要分析了筋腱失效时的瞬态响应,筋腱同时失效和渐进失效下的...对张力腿平台(tension leg platform,TLP)在不同系泊失效条件下的动态响应进行分析,采用全耦合数值工具ANSYS/AQWA建立非线性平台-筋腱模型,并提出一种模拟筋腱失效的方法。主要分析了筋腱失效时的瞬态响应,筋腱同时失效和渐进失效下的平台瞬态响应,以及筋腱失效后平台的性能变化。结果表明:首先,筋腱断裂失效会导致平台产生瞬时过冲;其次,筋腱同时失效下的瞬态响应比筋腱渐进失效的瞬态响应更显著;最后,筋腱失效后平台的性能会发生明显的变化。因此,需提前研究筋腱断裂对平台动态响应的影响,防止平台的安全性受到威胁。展开更多
An investigation of the characteristics of flowrate transientswithin slug flow was conducted in a large- scale outdoor testingfacility. The test section consisted of a 378 m long, 7.62 cmdiameter stainless steel pipe....An investigation of the characteristics of flowrate transientswithin slug flow was conducted in a large- scale outdoor testingfacility. The test section consisted of a 378 m long, 7.62 cmdiameter stainless steel pipe. Air and water were used as the testfluids. The response to a change of flowrate of either phase or twophases Was measured using a series of pressure transducers anddifferential pressure transducers. An increase or decrease In gasflowrate caused a pressure overshoot above the value at new steadystate or led to a pressure undershoot To form a temporary stratifiedflow.展开更多
A 30 MHz voltage-mode controlled buck converter with fast transient responses is presented.An improved differential difference amplifier(DDA)-based Type-III compensator is proposed to reduce the settling times of the ...A 30 MHz voltage-mode controlled buck converter with fast transient responses is presented.An improved differential difference amplifier(DDA)-based Type-III compensator is proposed to reduce the settling times of the converter during load transients,and to achieve near-optimal transient responses with simple PWM control only.Moreover,a hybrid scheme using a digital linear regulator with automatic transient detection and seamless loop transition is proposed to further improve the transient responses.By monitoring the output voltage of the compensator instead of the output voltage of the converter,the proposed hybrid scheme can reduce undershoot and overshoot effectively with good noise immunity and without interrupting the PWM loop.The converter was fabricated in a 0.13μm standard CMOS process using 3.3 V devices.With an input voltage of 3.3 V,the measured peak efficiencies at the output voltages of 2.4,1.8,and 1.2 V are 90.7%,88%,and 83.6%,respectively.With a load step of 1.25 A and rise and fall times of 2 ns,the measured 1%settling times were 220 and 230 ns,with undershoot and overshoot with PWM control of 72 and 76 mV,respectively.They were further reduced to 36 and 38 mV by using the proposed hybrid scheme,and 1%settling times were also reduced to 125 ns.展开更多
文摘对张力腿平台(tension leg platform,TLP)在不同系泊失效条件下的动态响应进行分析,采用全耦合数值工具ANSYS/AQWA建立非线性平台-筋腱模型,并提出一种模拟筋腱失效的方法。主要分析了筋腱失效时的瞬态响应,筋腱同时失效和渐进失效下的平台瞬态响应,以及筋腱失效后平台的性能变化。结果表明:首先,筋腱断裂失效会导致平台产生瞬时过冲;其次,筋腱同时失效下的瞬态响应比筋腱渐进失效的瞬态响应更显著;最后,筋腱失效后平台的性能会发生明显的变化。因此,需提前研究筋腱断裂对平台动态响应的影响,防止平台的安全性受到威胁。
基金Supported by the National Natural Science Foundation of China (No.59995462) and the National Science Foundation of China for distinguished Young Scientists (No. 59725616).
文摘An investigation of the characteristics of flowrate transientswithin slug flow was conducted in a large- scale outdoor testingfacility. The test section consisted of a 378 m long, 7.62 cmdiameter stainless steel pipe. Air and water were used as the testfluids. The response to a change of flowrate of either phase or twophases Was measured using a series of pressure transducers anddifferential pressure transducers. An increase or decrease In gasflowrate caused a pressure overshoot above the value at new steadystate or led to a pressure undershoot To form a temporary stratifiedflow.
文摘A 30 MHz voltage-mode controlled buck converter with fast transient responses is presented.An improved differential difference amplifier(DDA)-based Type-III compensator is proposed to reduce the settling times of the converter during load transients,and to achieve near-optimal transient responses with simple PWM control only.Moreover,a hybrid scheme using a digital linear regulator with automatic transient detection and seamless loop transition is proposed to further improve the transient responses.By monitoring the output voltage of the compensator instead of the output voltage of the converter,the proposed hybrid scheme can reduce undershoot and overshoot effectively with good noise immunity and without interrupting the PWM loop.The converter was fabricated in a 0.13μm standard CMOS process using 3.3 V devices.With an input voltage of 3.3 V,the measured peak efficiencies at the output voltages of 2.4,1.8,and 1.2 V are 90.7%,88%,and 83.6%,respectively.With a load step of 1.25 A and rise and fall times of 2 ns,the measured 1%settling times were 220 and 230 ns,with undershoot and overshoot with PWM control of 72 and 76 mV,respectively.They were further reduced to 36 and 38 mV by using the proposed hybrid scheme,and 1%settling times were also reduced to 125 ns.