To improve the combustor performance of multi-point injection combustion,lobe nozzle design was applied to the aero-engine model combustor,by presetting the swirl through a certain twisted angle of the edge of the lob...To improve the combustor performance of multi-point injection combustion,lobe nozzle design was applied to the aero-engine model combustor,by presetting the swirl through a certain twisted angle of the edge of the lobe outlet.Numerical simulation in combination with modelling test is used in this paper.The effects of swirl vorticity presetting onto the vortex structure,the characteristics of combustion temperature field,the combustor exit temperature field quality,the combustion efficiency,and the NOx emissions of multi-point injection combustion chamber are investigated.Compared with the conventional vortex flow at the lobe outlet edge,the results of numerical simulation and water modelling test of the swirl vorticity presetting show that the swirl presetting can efficiently enhance the range and intensity of the lobe-induced vorticities.Besides,it can improve the uniformity of the combustion temperature in the combustor chamber,together with the reduced emissions of the pollutant NOx.Moreover,compared with the conventional lobe nozzle chamber,the swirl vortex presetting can effectively improve its combustion performance.The flow simulation test results demonstrate the fluid vortex structure in the combustion chamber and validate the simulation results.展开更多
Computational fluid dynamics( CFD) is used to investigate a new type of two-chamber natural gas distributor,which has a natural gas inlet and nine nozzle outlets. The uniformity at the outlet of distributor is practic...Computational fluid dynamics( CFD) is used to investigate a new type of two-chamber natural gas distributor,which has a natural gas inlet and nine nozzle outlets. The uniformity at the outlet of distributor is practice proven to have significant degree influence on its comprehensive performance. To improve the uniformity at the nozzles of the gas distributor,CFD modeling with the RNG k-ε turbulence model is undertaken to understand the mass flow rate of nozzles with reference to different length of chambers and the most optimal length is obtained. The internal flow pattern of the natural gas distributor is analyzed. It is found that the local maximum deviation of the nozzle outflow rate increases with the increase of chambers length when the length is more than 64 mm. The results provide useful suggestions for the optimal design of two-chamber natural gas distributor.展开更多
基金supported by the Natural Science Fund of Liaoning Province Project (No. 201602566)
文摘To improve the combustor performance of multi-point injection combustion,lobe nozzle design was applied to the aero-engine model combustor,by presetting the swirl through a certain twisted angle of the edge of the lobe outlet.Numerical simulation in combination with modelling test is used in this paper.The effects of swirl vorticity presetting onto the vortex structure,the characteristics of combustion temperature field,the combustor exit temperature field quality,the combustion efficiency,and the NOx emissions of multi-point injection combustion chamber are investigated.Compared with the conventional vortex flow at the lobe outlet edge,the results of numerical simulation and water modelling test of the swirl vorticity presetting show that the swirl presetting can efficiently enhance the range and intensity of the lobe-induced vorticities.Besides,it can improve the uniformity of the combustion temperature in the combustor chamber,together with the reduced emissions of the pollutant NOx.Moreover,compared with the conventional lobe nozzle chamber,the swirl vortex presetting can effectively improve its combustion performance.The flow simulation test results demonstrate the fluid vortex structure in the combustion chamber and validate the simulation results.
基金Sponsored by the Beijing Key Lab of Heating,Gas Supply,Ventilating and Air Conditioning Engineering(Grant No.NR2013K04)the Higher School Science and Technology Development Fund of Tianjin(Grant No.20130909)
文摘Computational fluid dynamics( CFD) is used to investigate a new type of two-chamber natural gas distributor,which has a natural gas inlet and nine nozzle outlets. The uniformity at the outlet of distributor is practice proven to have significant degree influence on its comprehensive performance. To improve the uniformity at the nozzles of the gas distributor,CFD modeling with the RNG k-ε turbulence model is undertaken to understand the mass flow rate of nozzles with reference to different length of chambers and the most optimal length is obtained. The internal flow pattern of the natural gas distributor is analyzed. It is found that the local maximum deviation of the nozzle outflow rate increases with the increase of chambers length when the length is more than 64 mm. The results provide useful suggestions for the optimal design of two-chamber natural gas distributor.