期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Standardization of Tritium Water by TDCR Method 被引量:1
1
作者 吴永乐 梁珺成 +6 位作者 柳加成 熊文俊 姚顺和 郭晓清 陈细林 杨元第 袁大庆 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第7期644-646,共3页
The triple-to-double coincidence ratio (TDCR) method of liquid scintillation count- ing is an absolute measurement method of radioactivity. The formulation of the TDCR method and the established TDCR liquid scintill... The triple-to-double coincidence ratio (TDCR) method of liquid scintillation count- ing is an absolute measurement method of radioactivity. The formulation of the TDCR method and the established TDCR liquid scintillation counter are presented in this paper. The NIST standard reference material (SRM) of tritium water was measured to verify the performance of the TDCR liquid scintillation counter. 展开更多
关键词 liquid scintillation counters tdcr method activity of tritium water NISTSRM
下载PDF
液闪TDCR活度测量装置的研制 被引量:2
2
作者 吴永乐 梁珺成 +6 位作者 刘浩然 柳加成 姚顺和 岳会国 刘森林 杨元第 袁大庆 《计量学报》 CSCD 北大核心 2014年第1期83-86,共4页
建立了基于效率计算的液闪三双符合比活度测量装置,通过设定甄别阈、扩展死时间、符合技术手段消除了光电倍增管的热噪声和余后脉冲的影响。该装置测量氚水、14C和99Tc的双管符合探测效率达到54%、96.2%和97.2%。用NIST氚水标准... 建立了基于效率计算的液闪三双符合比活度测量装置,通过设定甄别阈、扩展死时间、符合技术手段消除了光电倍增管的热噪声和余后脉冲的影响。该装置测量氚水、14C和99Tc的双管符合探测效率达到54%、96.2%和97.2%。用NIST氚水标准物质对新建立的实验装置进行验证,En数检验结果满意。 展开更多
关键词 计量学 液闪计数器 三双符合比方法 活度测量
下载PDF
Standardization of tritiated water by the CIEMAT/NIST and TDCR methods 被引量:1
3
作者 WU YongLe LIU HaoRan +6 位作者 LIANG JunCheng LIU JiaCheng XIONG WenJun YUE HuiGuo LIU SenLin YANG YuanDi YUAN DaQing 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2015年第3期559-564,共6页
The activity of tritiated water has been standardized by two liquid scintillation counting methods:The CIEMAT/NIST method with the54Mn-standard efficiency tracing and the triple-to-double coincidence ratio(TDCR)method... The activity of tritiated water has been standardized by two liquid scintillation counting methods:The CIEMAT/NIST method with the54Mn-standard efficiency tracing and the triple-to-double coincidence ratio(TDCR)method.The samples were prepared with Ultima Gold TM AB liquid scintillation cocktail in low-potassium glass vials.In the application of the CIEMAT/NIST method,the computer program EMILIA was used to calculate the efficiency of3H and54Mn according to the KL1L2L3M atomic rearrangement model.And the detection efficiency of the TDCR counter was calculated using TDCR07 code,which makes it possible to allow for the potential asymmetry between the three photomultiplier tubes.The influence of stopping power and k B factor is discussed in the paper.When a power approach is adopted for the stopping power for electrons below 1ke V and k B is chosen to be 0.0075 cm/Me V,the relative deviation will be only 0.3%between the two methods. 展开更多
关键词 tritiated water the CIEMAT/NIST method the tdcr method k B factor the stopping power liquid scintillation counting
原文传递
液闪三双符合比方法测量^(99)Tc放射性活度 被引量:1
4
作者 吴永乐 刘浩然 +7 位作者 柳加成 李宏宇 梁珺成 熊文俊 姚顺和 陈细林 杨元第 袁大庆 《核电子学与探测技术》 CAS CSCD 北大核心 2014年第4期517-520,共4页
液闪三双符合比(TDCR)方法采用3个光电倍增管对称放置的液闪计数器,利用三管符合和三对两管符合的计数计算液闪探测效率,从而得到放射性活度,不需要使用标准源对仪器进行效率刻度,是一种放射性活度绝对测量方法。由于具有无自吸收、制... 液闪三双符合比(TDCR)方法采用3个光电倍增管对称放置的液闪计数器,利用三管符合和三对两管符合的计数计算液闪探测效率,从而得到放射性活度,不需要使用标准源对仪器进行效率刻度,是一种放射性活度绝对测量方法。由于具有无自吸收、制源简单、操作简便、一致性好等优点,已广泛应用于纯β衰变核素放射性活度的测量。介绍了液闪TDCR方法的基本原理和液闪TDCR活度测量装置,并绝对测量了纯β衰变核素99Tc放射性活度,测量不确定度小于0.3%。 展开更多
关键词 液闪计数器 三双符合比方法 放射性活度
下载PDF
氚化水放射性活度的绝对测量 被引量:1
5
作者 吴永乐 刘浩然 +3 位作者 柳加成 梁珺成 杨元第 袁大庆 《核化学与放射化学》 CAS CSCD 北大核心 2016年第1期32-37,共6页
液体闪烁计数器具有无自吸收、制源简单、操作简便等特点,测量氚化水具有一定优势。利用液闪CIEMAT/NIST方法和三双符合比(TDCR)方法校准氚化水的比活度,旨在为氚化水标准物质的研制提供定值手段。以54 Mn作为示踪核素应用CIEMAT/NIST... 液体闪烁计数器具有无自吸收、制源简单、操作简便等特点,测量氚化水具有一定优势。利用液闪CIEMAT/NIST方法和三双符合比(TDCR)方法校准氚化水的比活度,旨在为氚化水标准物质的研制提供定值手段。以54 Mn作为示踪核素应用CIEMAT/NIST方法标准化氚化水比活度,合成标准不确定度为0.80%。液闪TDCR方法应用装配有3个光电倍增管的计数器,根据测量的符合信息直接计算得到探测效率,绝对测量氚化水比活度,合成标准不确定度为0.66%。应用这两种方法测量了同一组氚化水淬灭系列源,测量结果 En数检验满意。 展开更多
关键词 氚化水 液闪测量 tdcr方法 CIEMAT/NIST方法
下载PDF
TDCR方法测量^(226)Ra溶液活度
6
作者 王载勇 张兆山 +2 位作者 杨元第 喻建华 梁珺成 《核电子学与探测技术》 CAS CSCD 北大核心 2011年第2期178-182,共5页
用液体闪烁技术-TDCR方法对使用进口^(226)Ra溶液制备的2个密封平行的^(226)Ra液体闪烁源进行了为期一个多月放射性活度测量。最后测量的结果与用γ谱仪方法给出的测量结果进行了比对,发现两组数据在1.25%和1.60%的误差范围,测量的结果... 用液体闪烁技术-TDCR方法对使用进口^(226)Ra溶液制备的2个密封平行的^(226)Ra液体闪烁源进行了为期一个多月放射性活度测量。最后测量的结果与用γ谱仪方法给出的测量结果进行了比对,发现两组数据在1.25%和1.60%的误差范围,测量的结果令人满意。研究表明:液体闪烁技术-TDCR方法是测量^(226)Ra溶液的一种快速、准确、可靠的测量方法。 展开更多
关键词 tdcr方法绝对测量 液体闪烁源 放射性平衡
下载PDF
上一页 1 下一页 到第