The operating corneoloscope and Terry operative keratometer were used respectively in 29 and 34 eyes during the intraocular lens implantation to measure the corneal astigmatism qualitatively or quantitatively,so that ...The operating corneoloscope and Terry operative keratometer were used respectively in 29 and 34 eyes during the intraocular lens implantation to measure the corneal astigmatism qualitatively or quantitatively,so that the tension of incision closure could be adjusted. The surgically induced astigmatism in qualitative group two weeks after the operation was 3. 5 ± 1. 70 D and that in quantitative group was 2. 56±1. 60 D. There were 55.17% and 38. 24% of the eyes with over 2. 00 D corneal astigmatism in qu...展开更多
Purpose:To investigate a simple method during extracapsular cataract extraction with posteior chamber intraocular lens implantation in order to reduce surgically induced corneal astig-matism.Methods:A modified scleral...Purpose:To investigate a simple method during extracapsular cataract extraction with posteior chamber intraocular lens implantation in order to reduce surgically induced corneal astig-matism.Methods:A modified scleral flap incision was used in the extracapsular cataract extraction with intraocular lens implantation and the postoperative changes in conreal astigmatism was observed.Results:The peak value of postoperative corneal astigmatism was3.60D,and the corneal astigmatism regression was 2.11D,surgically induced astigmatism was less significant in modified scleral flap incision group than that in convention-al limbal incison group(P<0.05).Conclusions:The modified scleral flap inciston is an ideal incision for cataract ex-traction with intraocular lens implantation when phacoemulsifier is not avaliable.Eye Science1995;11:136-139.展开更多
文摘The operating corneoloscope and Terry operative keratometer were used respectively in 29 and 34 eyes during the intraocular lens implantation to measure the corneal astigmatism qualitatively or quantitatively,so that the tension of incision closure could be adjusted. The surgically induced astigmatism in qualitative group two weeks after the operation was 3. 5 ± 1. 70 D and that in quantitative group was 2. 56±1. 60 D. There were 55.17% and 38. 24% of the eyes with over 2. 00 D corneal astigmatism in qu...
文摘Purpose:To investigate a simple method during extracapsular cataract extraction with posteior chamber intraocular lens implantation in order to reduce surgically induced corneal astig-matism.Methods:A modified scleral flap incision was used in the extracapsular cataract extraction with intraocular lens implantation and the postoperative changes in conreal astigmatism was observed.Results:The peak value of postoperative corneal astigmatism was3.60D,and the corneal astigmatism regression was 2.11D,surgically induced astigmatism was less significant in modified scleral flap incision group than that in convention-al limbal incison group(P<0.05).Conclusions:The modified scleral flap inciston is an ideal incision for cataract ex-traction with intraocular lens implantation when phacoemulsifier is not avaliable.Eye Science1995;11:136-139.