AIM: To evaluate the effectiveness of two different strategies using radiofrequency catheter ablation for redo procedures after cryoablation of atrial fibrillation.METHODS: Thirty patients(paroxysmal atrial fibrillati...AIM: To evaluate the effectiveness of two different strategies using radiofrequency catheter ablation for redo procedures after cryoablation of atrial fibrillation.METHODS: Thirty patients(paroxysmal atrial fibrillation: 22 patients,persistent atrial fibrillation: 8 patients) had to undergo a redo procedure after initially successful circumferential pulmonary vein(PV) isolation with the cryoballoon technique(Arctic Front Balloon,CryoCath Technologies/Medtronic).The redo ablation procedures were performed using a segmental approach or a circumferential ablation strategy(CARTO;Biosense Webster) depending on the intra-procedural findings.After discharge,patients were scheduled for repeated visits at the arrhythmia clinic.A 7-day Holter monitoring was performed at 3,12 and 24 mo after the ablation procedure.RESULTS: During the redo procedure,a mean number of 2.9 re-conducting pulmonary veins(SD ± 1.0 PVs) were detected(using a circular mapping catheter).In 20 patients,a segmental approach was sufficient to eliminate the residual pulmonary vein conduction because there were only a few recovered pulmonary vein fibres.In the remaining 10 patients,a circumferential ablation strategy was used because of a complete recovery of the PV-LA conduction.All recovered pulmonary veins could be isolated successfully again.At 2-year follow-up,73.3% of all patients were free from an arrhythmia recurrence(22/30).There were no major complications.CONCLUSION: In patients with an initial circumferential pulmonary vein isolation using the cryoballoon technique,a repeat ablation procedure can be performed safely and effectively using radiofrequency catheter ablation.展开更多
We report the case of a 14-year-old boy with ventricular preexcitation. A standard, fluoroscopy guided, ablation procedure was successfully performed in a postero-midseptal region with a total fluoroscopy time of abou...We report the case of a 14-year-old boy with ventricular preexcitation. A standard, fluoroscopy guided, ablation procedure was successfully performed in a postero-midseptal region with a total fluoroscopy time of about 45 min (2430 cGy.cm2). A few hours after the procedure, preexcitation reappeared. A second ablation procedure was scheduled using the EnSite NavXTM mapping system. During mapping along the tricuspid groove, preexcitation suddenly disappeared due to mechanical "bumping" of the accessory pathway and it did not recover over the next 30 min. As per our routine practice, the phase of geometry reconstruction has been continuously recorded by the system; thus, an off-line analysis allowed to pinpoint the site of earliest activation and the site of mechanical bumping, where radiofrequency obtained the accessory pathway ablation. The second procedure was performed without using fluoroscopy at all. Thanks to the geometry reconstruction, the procedure was completely successful thus avoiding a further rehospitalization.展开更多
文摘AIM: To evaluate the effectiveness of two different strategies using radiofrequency catheter ablation for redo procedures after cryoablation of atrial fibrillation.METHODS: Thirty patients(paroxysmal atrial fibrillation: 22 patients,persistent atrial fibrillation: 8 patients) had to undergo a redo procedure after initially successful circumferential pulmonary vein(PV) isolation with the cryoballoon technique(Arctic Front Balloon,CryoCath Technologies/Medtronic).The redo ablation procedures were performed using a segmental approach or a circumferential ablation strategy(CARTO;Biosense Webster) depending on the intra-procedural findings.After discharge,patients were scheduled for repeated visits at the arrhythmia clinic.A 7-day Holter monitoring was performed at 3,12 and 24 mo after the ablation procedure.RESULTS: During the redo procedure,a mean number of 2.9 re-conducting pulmonary veins(SD ± 1.0 PVs) were detected(using a circular mapping catheter).In 20 patients,a segmental approach was sufficient to eliminate the residual pulmonary vein conduction because there were only a few recovered pulmonary vein fibres.In the remaining 10 patients,a circumferential ablation strategy was used because of a complete recovery of the PV-LA conduction.All recovered pulmonary veins could be isolated successfully again.At 2-year follow-up,73.3% of all patients were free from an arrhythmia recurrence(22/30).There were no major complications.CONCLUSION: In patients with an initial circumferential pulmonary vein isolation using the cryoballoon technique,a repeat ablation procedure can be performed safely and effectively using radiofrequency catheter ablation.
文摘We report the case of a 14-year-old boy with ventricular preexcitation. A standard, fluoroscopy guided, ablation procedure was successfully performed in a postero-midseptal region with a total fluoroscopy time of about 45 min (2430 cGy.cm2). A few hours after the procedure, preexcitation reappeared. A second ablation procedure was scheduled using the EnSite NavXTM mapping system. During mapping along the tricuspid groove, preexcitation suddenly disappeared due to mechanical "bumping" of the accessory pathway and it did not recover over the next 30 min. As per our routine practice, the phase of geometry reconstruction has been continuously recorded by the system; thus, an off-line analysis allowed to pinpoint the site of earliest activation and the site of mechanical bumping, where radiofrequency obtained the accessory pathway ablation. The second procedure was performed without using fluoroscopy at all. Thanks to the geometry reconstruction, the procedure was completely successful thus avoiding a further rehospitalization.