This study presents a novel compound muscle action potential(CMAP)examination of motor unit changes in paretic muscle post stroke.CMAP scan of the first dorsal interosseous(FDI)muscle was performed bilaterally in 16 c...This study presents a novel compound muscle action potential(CMAP)examination of motor unit changes in paretic muscle post stroke.CMAP scan of the first dorsal interosseous(FDI)muscle was performed bilaterally in 16 chronic stroke subjects.Various parameters were derived from the CMAP scan to examine paretic muscle changes,including CMAP amplitude,D50,step index(STEPIX)and amplitude index(AMPIX).A significant decrease in CMAP amplitude and STEPIX was observed in paretic muscles compared with contralateral muscles(CMAP amplitude:paretic(9.0±0.5)mV,contralateral(11.3±0.9)mV,P=0.024;STEPIX:paretic 101.2±7.6,contralateral 121.9±6.5,P=0.020).No significant difference in D50 and AMPIX was observed between the paretic and contralateral sides(P>0.05).The findings revealed complex paretic muscle changes including motor unit degeneration,muscle fiber denervation,reinnervation and atrophy,providing useful insights to help understand neuromuscular mechanisms associated with weakness and other functional deterioration post stroke.The CMAP scan experimental protocols and the applied processing methods are noninvasive,convenient,and automated,offering practical benefits for clinical application.展开更多
We experimentally demonstrate for the first time, to the best of our knowledge, an all-fiber passively mode-locked laser operation based on the nonlinear multimode interference of step-index multimode fiber. Such a st...We experimentally demonstrate for the first time, to the best of our knowledge, an all-fiber passively mode-locked laser operation based on the nonlinear multimode interference of step-index multimode fiber. Such a structure couples the light in and out of the multimode fiber via single-mode fibers, and its physical mechanisms for saturable absorption have been analyzed theoretically based on the third-order nonlinear Kerr effect of multimode fiber. Using the nonlinear multimode interference structure with 48.8 mm length step-index multimode fiber, the modulation depth has been measured to be ~5%. The passively mode-locked laser output pulses have a central wavelength of 1596.66 nm, bandwidth of 2.18 nm, pulsewidth of ~625 fs, and fundamental repetition rate of8.726 MHz. Furthermore, the influence of total cavity dispersion on the optical spectrum, pulse width, and output power is investigated systematically by adding different lengths of single-mode fiber and dispersion compensation fiber in the laser cavity.展开更多
基金supported by the National Natural Science Foundation of China(82102179)the Shandong Provincial Natural Science Foundation(ZR2020KF012,ZR2021QH267,ZR2021QH053)+2 种基金the Shanghai Municipal Key Clinical Specialty(shslczdzk02701)the National Institutes of Health(7 R21 NS113716-02)the National Institute on Disability and Rehabilitation Research(90REMM0001-01-00).
文摘This study presents a novel compound muscle action potential(CMAP)examination of motor unit changes in paretic muscle post stroke.CMAP scan of the first dorsal interosseous(FDI)muscle was performed bilaterally in 16 chronic stroke subjects.Various parameters were derived from the CMAP scan to examine paretic muscle changes,including CMAP amplitude,D50,step index(STEPIX)and amplitude index(AMPIX).A significant decrease in CMAP amplitude and STEPIX was observed in paretic muscles compared with contralateral muscles(CMAP amplitude:paretic(9.0±0.5)mV,contralateral(11.3±0.9)mV,P=0.024;STEPIX:paretic 101.2±7.6,contralateral 121.9±6.5,P=0.020).No significant difference in D50 and AMPIX was observed between the paretic and contralateral sides(P>0.05).The findings revealed complex paretic muscle changes including motor unit degeneration,muscle fiber denervation,reinnervation and atrophy,providing useful insights to help understand neuromuscular mechanisms associated with weakness and other functional deterioration post stroke.The CMAP scan experimental protocols and the applied processing methods are noninvasive,convenient,and automated,offering practical benefits for clinical application.
基金National Natural Science Foundation of China(NSFC)(11547187)Shandong Provincial Key RD Program(2017CXGC0416)Natural Science Foundation of Shandong Province(ZR2016FB17,ZR2017MA047)
文摘We experimentally demonstrate for the first time, to the best of our knowledge, an all-fiber passively mode-locked laser operation based on the nonlinear multimode interference of step-index multimode fiber. Such a structure couples the light in and out of the multimode fiber via single-mode fibers, and its physical mechanisms for saturable absorption have been analyzed theoretically based on the third-order nonlinear Kerr effect of multimode fiber. Using the nonlinear multimode interference structure with 48.8 mm length step-index multimode fiber, the modulation depth has been measured to be ~5%. The passively mode-locked laser output pulses have a central wavelength of 1596.66 nm, bandwidth of 2.18 nm, pulsewidth of ~625 fs, and fundamental repetition rate of8.726 MHz. Furthermore, the influence of total cavity dispersion on the optical spectrum, pulse width, and output power is investigated systematically by adding different lengths of single-mode fiber and dispersion compensation fiber in the laser cavity.