为有效提高风电场的并网运行能力,将电池储能系统(battery energy storage system,BESS)-静止同步补偿器(static compensator,STATCOM)串联集成单元与风力发电单元相结合,建立基于Park变换的BESS-STATCOM集成单元和基于异步发电机风力...为有效提高风电场的并网运行能力,将电池储能系统(battery energy storage system,BESS)-静止同步补偿器(static compensator,STATCOM)串联集成单元与风力发电单元相结合,建立基于Park变换的BESS-STATCOM集成单元和基于异步发电机风力发电系统的整体动态数学模型,通过理论推导和基于仿真平台PSCAD对不同风速时风电场的出力及并网点的电压进行计算,结果表明,BESS-STATCOM集成单元具有快速功率调节能力,使风力发电单元可作为调度机组单元运行;在求解包含风电场的电力系统潮流时,可以将其视为PV节点,而且能够显著提高电网的运行稳定性和供电可靠性。展开更多
A new inter-cluster DC capacitor voltage balancing scheme for a delta connected modular multilevel cascaded converter (MMCC)-based static synchronous compensator (STATCOM) is presented. A detailed power flow analysis ...A new inter-cluster DC capacitor voltage balancing scheme for a delta connected modular multilevel cascaded converter (MMCC)-based static synchronous compensator (STATCOM) is presented. A detailed power flow analysis of applying negative sequence current (NSC) and zero-sequence current (ZSC) injection methods in addressing the issue of inter-cluster DC voltage imbalance under unbalance grid voltage is carried out. A control scheme is proposed which integrates both inter-cluster methods using a quantification factor QF. This is used to achieve the sharing of the inter-cluster active power between the NSC and ZSC injection methods. An accurate method of determining the quantification factor is also presented. The proposed method offers better sub-module DC capacitor voltage balancing and prevents converter overcurrent. The influence of unbalanced grid voltage on the delta connected MMCC-based STATCOM rating using this integrated cluster balancing technique is investigated. The control scheme is verified with a 5 kV 1.2MVA MMCC-STATCOM using 3-level bridge sub-modules, and the results show the advantages of the proposed method over other inter-cluster methods.展开更多
We present the ferroresonance overvoltage mitigation concerning the power systems of the grid-connectcd wind energy conversion systems(WECSs).WECS is considered based on a doubly-fed induction generator(DFIG).Ferrores...We present the ferroresonance overvoltage mitigation concerning the power systems of the grid-connectcd wind energy conversion systems(WECSs).WECS is considered based on a doubly-fed induction generator(DFIG).Ferroresonance overvoltage associated with a single-pole outage of the line breaker is mitigated by fast regulating the reactive power using the static compensator(STATCOM).STATCOM controller is introduced,in which t>\o incorporated proportional-integral(PI)controllers are optimally tuned using a modified flow-er pollination algorithm(MFPA)as an optimization technique.To show the capability of the proposed STATCOM controller in mitigating the ferroresonance overvoltage,two test cases are introduced,which are based on the interconnection status of the power transformer used with the grid-connected DFIGs.The results show that the ferroresonance disturbance can occur for the power transformers installed in the wind farms although the transformer terminals are interconnected,and neither side of the transformer is isolated.Furthermore,as a mitigation method of ferroresonance overvoltage,the proposed STATCOM controller succeeds in improving the system voltage profile and speed profile of the wind turbine as well as protecting the system components against the ferroresonance overvoltage.展开更多
This paper presents a novel inter-cluster direct current(DC)capacitor voltage balancing control scheme for the single-star configured modular multilevel cascaded converter(MMCC)-based static synchronous compensator(ST...This paper presents a novel inter-cluster direct current(DC)capacitor voltage balancing control scheme for the single-star configured modular multilevel cascaded converter(MMCC)-based static synchronous compensator(STATCOM)under unbalanced grid voltage.The negative-sequence component of grid voltage at the point of common connection(PCC)causes unbalanced active power flow in the phase limbs of converter.This leads to the imbalance of DC voltages of the sub-module capacitors across the MMCC phases,and consequently,the malfunction of converter.The proposed solution is to inject both negative-sequence current(NSC)and zero-sequence voltage(ZSV)into the phase limbs of MMCC.A quantification factor Qf is used to achieve the sharing of inter-cluster active pow-er between the NSC and ZSV injection methods.Accurate determination of the quantification factor has been presented.In addition to maintaining the DC voltages of sub-module capacitor across the MMCC phases balanced,it also prevents the overcurrent and overvoltage of converter by injecting NSC and ZSV with the right proportion.The control scheme is validated on a 3.54 kV 1.2 MVA power system using MMCC-based STATCOM with 3-level bridge cells as sub-modules.The results show that the proposed scheme provides superior effectiveness in eliminating the voltage imbalance of DC capacitor in the phase limb while maintaining low voltage and current ratings.展开更多
There are several problems existing in the direct starting of asynchronous motor such as large starting current,reactive power absorption from network side and weak interference-resistance,etc.Aiming at this,a compreh...There are several problems existing in the direct starting of asynchronous motor such as large starting current,reactive power absorption from network side and weak interference-resistance,etc.Aiming at this,a comprehensive energy-saving optimization model of asynchronous motor for voltage regulation based on static synchronous compensator(STATCOM)is put forward.By analyzing the working principle and operation performance of static synchronous compensator regulating voltage,a new energy-efficient optimization method for asynchronous motor is proposed based on the voltage regulator model to achieve soft start,continuous dynamic reactive power compensation and the terminal voltage stability control.The multi-objective optimal operation of asynchronous motor is realized by controlling the inverter to adjust the reactive current dynamically.The strategy reduces the influence of starting current and grid voltage by soft starting,and realizes the function of reactive power compensation and terminal voltage stabilization.The effectiveness and superiority of the proposed model is verified by the simulation analysis and the results of comparison with the motor started directly.展开更多
文摘为有效提高风电场的并网运行能力,将电池储能系统(battery energy storage system,BESS)-静止同步补偿器(static compensator,STATCOM)串联集成单元与风力发电单元相结合,建立基于Park变换的BESS-STATCOM集成单元和基于异步发电机风力发电系统的整体动态数学模型,通过理论推导和基于仿真平台PSCAD对不同风速时风电场的出力及并网点的电压进行计算,结果表明,BESS-STATCOM集成单元具有快速功率调节能力,使风力发电单元可作为调度机组单元运行;在求解包含风电场的电力系统潮流时,可以将其视为PV节点,而且能够显著提高电网的运行稳定性和供电可靠性。
文摘A new inter-cluster DC capacitor voltage balancing scheme for a delta connected modular multilevel cascaded converter (MMCC)-based static synchronous compensator (STATCOM) is presented. A detailed power flow analysis of applying negative sequence current (NSC) and zero-sequence current (ZSC) injection methods in addressing the issue of inter-cluster DC voltage imbalance under unbalance grid voltage is carried out. A control scheme is proposed which integrates both inter-cluster methods using a quantification factor QF. This is used to achieve the sharing of the inter-cluster active power between the NSC and ZSC injection methods. An accurate method of determining the quantification factor is also presented. The proposed method offers better sub-module DC capacitor voltage balancing and prevents converter overcurrent. The influence of unbalanced grid voltage on the delta connected MMCC-based STATCOM rating using this integrated cluster balancing technique is investigated. The control scheme is verified with a 5 kV 1.2MVA MMCC-STATCOM using 3-level bridge sub-modules, and the results show the advantages of the proposed method over other inter-cluster methods.
文摘We present the ferroresonance overvoltage mitigation concerning the power systems of the grid-connectcd wind energy conversion systems(WECSs).WECS is considered based on a doubly-fed induction generator(DFIG).Ferroresonance overvoltage associated with a single-pole outage of the line breaker is mitigated by fast regulating the reactive power using the static compensator(STATCOM).STATCOM controller is introduced,in which t>\o incorporated proportional-integral(PI)controllers are optimally tuned using a modified flow-er pollination algorithm(MFPA)as an optimization technique.To show the capability of the proposed STATCOM controller in mitigating the ferroresonance overvoltage,two test cases are introduced,which are based on the interconnection status of the power transformer used with the grid-connected DFIGs.The results show that the ferroresonance disturbance can occur for the power transformers installed in the wind farms although the transformer terminals are interconnected,and neither side of the transformer is isolated.Furthermore,as a mitigation method of ferroresonance overvoltage,the proposed STATCOM controller succeeds in improving the system voltage profile and speed profile of the wind turbine as well as protecting the system components against the ferroresonance overvoltage.
文摘This paper presents a novel inter-cluster direct current(DC)capacitor voltage balancing control scheme for the single-star configured modular multilevel cascaded converter(MMCC)-based static synchronous compensator(STATCOM)under unbalanced grid voltage.The negative-sequence component of grid voltage at the point of common connection(PCC)causes unbalanced active power flow in the phase limbs of converter.This leads to the imbalance of DC voltages of the sub-module capacitors across the MMCC phases,and consequently,the malfunction of converter.The proposed solution is to inject both negative-sequence current(NSC)and zero-sequence voltage(ZSV)into the phase limbs of MMCC.A quantification factor Qf is used to achieve the sharing of inter-cluster active pow-er between the NSC and ZSV injection methods.Accurate determination of the quantification factor has been presented.In addition to maintaining the DC voltages of sub-module capacitor across the MMCC phases balanced,it also prevents the overcurrent and overvoltage of converter by injecting NSC and ZSV with the right proportion.The control scheme is validated on a 3.54 kV 1.2 MVA power system using MMCC-based STATCOM with 3-level bridge cells as sub-modules.The results show that the proposed scheme provides superior effectiveness in eliminating the voltage imbalance of DC capacitor in the phase limb while maintaining low voltage and current ratings.
文摘There are several problems existing in the direct starting of asynchronous motor such as large starting current,reactive power absorption from network side and weak interference-resistance,etc.Aiming at this,a comprehensive energy-saving optimization model of asynchronous motor for voltage regulation based on static synchronous compensator(STATCOM)is put forward.By analyzing the working principle and operation performance of static synchronous compensator regulating voltage,a new energy-efficient optimization method for asynchronous motor is proposed based on the voltage regulator model to achieve soft start,continuous dynamic reactive power compensation and the terminal voltage stability control.The multi-objective optimal operation of asynchronous motor is realized by controlling the inverter to adjust the reactive current dynamically.The strategy reduces the influence of starting current and grid voltage by soft starting,and realizes the function of reactive power compensation and terminal voltage stabilization.The effectiveness and superiority of the proposed model is verified by the simulation analysis and the results of comparison with the motor started directly.