Geometric error is the main factor affecting the machining accuracy of hybrid machine tools.Kinematic calibration is an effective way to improve the geometric accuracy of hybrid machine tools.The necessity to measure ...Geometric error is the main factor affecting the machining accuracy of hybrid machine tools.Kinematic calibration is an effective way to improve the geometric accuracy of hybrid machine tools.The necessity to measure both position and orientation at each pose,as well as the instability of identification in case of incomplete measurements,severely affects the application of traditional calibration methods.In this study,a kinematic calibration method with high measurement efficiency and robust identification is proposed to improve the kinematic accuracy of a five-axis hybrid machine tool.First,the configuration is introduced,and an error model is derived.Further,by investigating the mechanism error characteristics,a measurement scheme that only requires tool centre point position error measurement and one alignment operation is proposed.Subsequently,by analysing the effects of unmeasured degrees of freedom(DOFs)on other DOFs,an improved nonlinear least squares method based on virtual measurement values is proposed to achieve stable parameter identification in case of incomplete measurement,without introducing additional parameters.Finally,the proposed calibration method is verified through simulations and experiments.The proposed method can efficiently accomplish the kinematic calibration of the hybrid machine tool.The accuracy of the hybrid machine tool is significantly improved after calibration,satisfying actual aerospace machining requirements.展开更多
The purpose of this study was to clarify grid convergence property of three-dimensional measurement-integrated (3D-MI) simulation for a flow behind a square cylinder with Karman vortex street. Measurement-integrated (...The purpose of this study was to clarify grid convergence property of three-dimensional measurement-integrated (3D-MI) simulation for a flow behind a square cylinder with Karman vortex street. Measurement-integrated (MI) simulation is a kind of the observer in the dynamical system theory by using CFD scheme as a mathematical model of the system. In a former study, two-dimensional MI (2D-MI) simulation with a coarse grid system showed a fairly good result in comparison with a 2D ordinary (2D-O) simulation, but the results were degraded with grid refinement. In this study, 3D-MI simulation and three-dimensional ordinary (3D-O) simulation were performed with three grid systems of different grid resolutions, and their grid convergence properties were compared. As a result, all 3D-MI simulations reproduced the vortex shedding frequency identical to that of the experiment, and the flow fields obtained were very close, within 5% difference between the results, while the results of the 3D-O simulations showed variation of the solution under convergence. It is shown that the grid convergence property of 3D-MI simulation is monotonic and better than that of 3D-O simulation, whereas those of 2D-O and 2D-MI simulations for streamwise velocity fluctuation are divergent. The solution of 3D-MI simulation with a relatively coarse grid system properly reproduces the basic three-dimensional structure of the wake flow as well as the drag and lift coefficients.展开更多
The optical diffraction is a major means of minute diameter measurements. Since the light intensity of the diffraction fringe, mainly distributed in the central bright stripes, and that will lead to a relatively low S...The optical diffraction is a major means of minute diameter measurements. Since the light intensity of the diffraction fringe, mainly distributed in the central bright stripes, and that will lead to a relatively low SNR for the signal of the senior stripes. The traditional dark stripes extraction algorithm affected greatly by the noise. So this paper presents an algorithm that could effectively eliminate the gross errorcaused by the noise. Than by curve fitting the local signal of the diffraction pattern with the least square principle, the system could achieve a high measurement precision.展开更多
In this paper, we consider the partially nonlinear errors-in-variables models when the non- parametric component is measured with additive error. The profile nonlinear least squares estimator of unknown parameter and ...In this paper, we consider the partially nonlinear errors-in-variables models when the non- parametric component is measured with additive error. The profile nonlinear least squares estimator of unknown parameter and the estimator of nonparametric component are constructed, and their asymptotic properties are derived under general assumptions. Finite sample performances of the proposed statistical inference procedures are illustrated by Monte Carlo simulation studies.展开更多
基金supported by the National Natural Science Foundation of China(Nos.52275442 and 51975319)。
文摘Geometric error is the main factor affecting the machining accuracy of hybrid machine tools.Kinematic calibration is an effective way to improve the geometric accuracy of hybrid machine tools.The necessity to measure both position and orientation at each pose,as well as the instability of identification in case of incomplete measurements,severely affects the application of traditional calibration methods.In this study,a kinematic calibration method with high measurement efficiency and robust identification is proposed to improve the kinematic accuracy of a five-axis hybrid machine tool.First,the configuration is introduced,and an error model is derived.Further,by investigating the mechanism error characteristics,a measurement scheme that only requires tool centre point position error measurement and one alignment operation is proposed.Subsequently,by analysing the effects of unmeasured degrees of freedom(DOFs)on other DOFs,an improved nonlinear least squares method based on virtual measurement values is proposed to achieve stable parameter identification in case of incomplete measurement,without introducing additional parameters.Finally,the proposed calibration method is verified through simulations and experiments.The proposed method can efficiently accomplish the kinematic calibration of the hybrid machine tool.The accuracy of the hybrid machine tool is significantly improved after calibration,satisfying actual aerospace machining requirements.
文摘The purpose of this study was to clarify grid convergence property of three-dimensional measurement-integrated (3D-MI) simulation for a flow behind a square cylinder with Karman vortex street. Measurement-integrated (MI) simulation is a kind of the observer in the dynamical system theory by using CFD scheme as a mathematical model of the system. In a former study, two-dimensional MI (2D-MI) simulation with a coarse grid system showed a fairly good result in comparison with a 2D ordinary (2D-O) simulation, but the results were degraded with grid refinement. In this study, 3D-MI simulation and three-dimensional ordinary (3D-O) simulation were performed with three grid systems of different grid resolutions, and their grid convergence properties were compared. As a result, all 3D-MI simulations reproduced the vortex shedding frequency identical to that of the experiment, and the flow fields obtained were very close, within 5% difference between the results, while the results of the 3D-O simulations showed variation of the solution under convergence. It is shown that the grid convergence property of 3D-MI simulation is monotonic and better than that of 3D-O simulation, whereas those of 2D-O and 2D-MI simulations for streamwise velocity fluctuation are divergent. The solution of 3D-MI simulation with a relatively coarse grid system properly reproduces the basic three-dimensional structure of the wake flow as well as the drag and lift coefficients.
文摘The optical diffraction is a major means of minute diameter measurements. Since the light intensity of the diffraction fringe, mainly distributed in the central bright stripes, and that will lead to a relatively low SNR for the signal of the senior stripes. The traditional dark stripes extraction algorithm affected greatly by the noise. So this paper presents an algorithm that could effectively eliminate the gross errorcaused by the noise. Than by curve fitting the local signal of the diffraction pattern with the least square principle, the system could achieve a high measurement precision.
基金Supported by National Natural Science Foundation of China(Grant Nos.11101014 and 11002005)the Beijing Natural Science Foundation(Grant No.1142002)+2 种基金the Doctoral Fund of Innovation of Beijing Universityof Technologythe Science and Technology Project of Beijing Municipal Education Commission(Grant No.KM201410005010)the Training Programme Foundation for the Beijing Municipal Excellent Talents(GrantNo.2013D005007000005)
文摘In this paper, we consider the partially nonlinear errors-in-variables models when the non- parametric component is measured with additive error. The profile nonlinear least squares estimator of unknown parameter and the estimator of nonparametric component are constructed, and their asymptotic properties are derived under general assumptions. Finite sample performances of the proposed statistical inference procedures are illustrated by Monte Carlo simulation studies.