The extended Kompaneets equation is reviewed. This equation can be applied not only to the up-Comptonization process but also to the down-Comptonization which is important in X-ray and γ-ray astronomy. Based on this ...The extended Kompaneets equation is reviewed. This equation can be applied not only to the up-Comptonization process but also to the down-Comptonization which is important in X-ray and γ-ray astronomy. Based on this equation, the variation of some typical X-ray spectrum in astrophysics due to the down-Comptonization is down-Cumptonimation, spectrum shape, diffusion approximation, extended Kompanects equation.展开更多
The noise of closed loop micro-electromechanical systems(MEMS) capacitive accelerometer is treated as one of the significant performance specifications.Traditional optimization of noise performance often focuses on de...The noise of closed loop micro-electromechanical systems(MEMS) capacitive accelerometer is treated as one of the significant performance specifications.Traditional optimization of noise performance often focuses on designing large capacitive sensitivity accelerometer and applying closed loop structure to shape total noise,but different noise sources in closed loop and their behaviors at low frequencies are seldom carefully studied,especially their behaviors with different electronic parameters.In this work,a thorough noise analysis is established focusing on the four noise sources transfer functions near 0 Hz with simplified electronic parameters in closed loop,and it is found that the total electronic noise equivalent acceleration varies differently at different frequency points,such that the noise spectrum shape at low frequencies can be altered from 1/f noise-like shape to flat spectrum shape.The bias instability changes as a consequence.With appropriate parameters settings,the 670 Hz resonant frequency accelerometer can reach resolution of 2.6 μg/(Hz)1/2 at 2 Hz and 6 μg bias instability,and 1300 Hz accelerometer can achieve 5μg/(Hz)1/2 at 2 Hz and 31 μg bias instability.Both accelerometers have flat spectrum profile from 2 Hz to 15 Hz.展开更多
文摘The extended Kompaneets equation is reviewed. This equation can be applied not only to the up-Comptonization process but also to the down-Comptonization which is important in X-ray and γ-ray astronomy. Based on this equation, the variation of some typical X-ray spectrum in astrophysics due to the down-Comptonization is down-Cumptonimation, spectrum shape, diffusion approximation, extended Kompanects equation.
基金Project(61404122)supported by the National Natural Science Foundation of China
文摘The noise of closed loop micro-electromechanical systems(MEMS) capacitive accelerometer is treated as one of the significant performance specifications.Traditional optimization of noise performance often focuses on designing large capacitive sensitivity accelerometer and applying closed loop structure to shape total noise,but different noise sources in closed loop and their behaviors at low frequencies are seldom carefully studied,especially their behaviors with different electronic parameters.In this work,a thorough noise analysis is established focusing on the four noise sources transfer functions near 0 Hz with simplified electronic parameters in closed loop,and it is found that the total electronic noise equivalent acceleration varies differently at different frequency points,such that the noise spectrum shape at low frequencies can be altered from 1/f noise-like shape to flat spectrum shape.The bias instability changes as a consequence.With appropriate parameters settings,the 670 Hz resonant frequency accelerometer can reach resolution of 2.6 μg/(Hz)1/2 at 2 Hz and 6 μg bias instability,and 1300 Hz accelerometer can achieve 5μg/(Hz)1/2 at 2 Hz and 31 μg bias instability.Both accelerometers have flat spectrum profile from 2 Hz to 15 Hz.