The corona current pulses generated by corona discharge are the sources of the radio interference from transmission lines and the detailed characteristics of the corona current pulses from conductor should be investig...The corona current pulses generated by corona discharge are the sources of the radio interference from transmission lines and the detailed characteristics of the corona current pulses from conductor should be investigated in order to reveal their generation mechanism.In this paper,the line-to-plane electrodes are designed to measure and analyze the characteristics of corona current pulses from positive corona discharges.The influences of inter-electrode gap and line diameters on the detail characteristics of corona current pulses,such as pulse amplitude,rise time,duration time and repetition frequency,are carefully analyzed.The obtained results show that the pulse amplitude and the repetition frequency increase with the diameter of line electrode when the electric fields on the surface of line electrodes are same.With the increase of inter-electrode gap,the pulse amplitude and the repetition frequency first decrease and then turn to be stable,while the rise time first increases and finally turns to be stable.The distributions of electric field and space charges under the line electrodes are calculated,and the influences of inter-electrode gap and line electrode diameter on the experimental results are qualitatively explained.展开更多
基金supported by National Natural Science Foundation of China under Grant No.51707066by the Fundamental Research Funds for the Central Universities under Grant No.2017 MS004 and No.XCA17003-04
文摘The corona current pulses generated by corona discharge are the sources of the radio interference from transmission lines and the detailed characteristics of the corona current pulses from conductor should be investigated in order to reveal their generation mechanism.In this paper,the line-to-plane electrodes are designed to measure and analyze the characteristics of corona current pulses from positive corona discharges.The influences of inter-electrode gap and line diameters on the detail characteristics of corona current pulses,such as pulse amplitude,rise time,duration time and repetition frequency,are carefully analyzed.The obtained results show that the pulse amplitude and the repetition frequency increase with the diameter of line electrode when the electric fields on the surface of line electrodes are same.With the increase of inter-electrode gap,the pulse amplitude and the repetition frequency first decrease and then turn to be stable,while the rise time first increases and finally turns to be stable.The distributions of electric field and space charges under the line electrodes are calculated,and the influences of inter-electrode gap and line electrode diameter on the experimental results are qualitatively explained.