Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used t...Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used to obtain balanced and sinusoidal source currents by injecting compensation currents.However,CCVSI with traditional controllers have a limited transient and steady state performance.In this paper,we propose an adaptive dynamic programming(ADP) controller with online learning capability to improve transient response and harmonics.The proposed controller works alongside existing proportional integral(PI) controllers to efficiently track the reference currents in the d-q domain.It can generate adaptive control actions to compensate the PI controller.The proposed system was simulated under different nonlinear(three-phase full wave rectifier) load conditions.The performance of the proposed approach was compared with the traditional approach.We have also included the simulation results without connecting the traditional PI control based power inverter for reference comparison.The online learning based ADP controller not only reduced average total harmonic distortion by 18.41%,but also outperformed traditional PI controllers during transients.展开更多
A novel and simple ifrea! control algorithm using digital signal processor (DSP) has been proposed and realized for a three phase shunt active filter (SAF). The simulation and prototype construction of SAF is cond...A novel and simple ifrea! control algorithm using digital signal processor (DSP) has been proposed and realized for a three phase shunt active filter (SAF). The simulation and prototype construction of SAF is conducted to compensate the reactive power and harmonics in a distribution system. The major feature of the proposed ifreal algorithm is that it does not require unit vector templates and any transformations for the reference current genera- tion of SAF. This reduces the computational complexity and makes the control flexible and faster. The simulation is conducted in MATLAB/SIMULINK while DSP TMS320LF2407 is employed in the digital implementation of hysteresis current control (HCC) for experimentation. The hardware results correlate with the simulation results in reducing the total harmonic distortion (THD) of the source current and achieving unity power factor.展开更多
文摘Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used to obtain balanced and sinusoidal source currents by injecting compensation currents.However,CCVSI with traditional controllers have a limited transient and steady state performance.In this paper,we propose an adaptive dynamic programming(ADP) controller with online learning capability to improve transient response and harmonics.The proposed controller works alongside existing proportional integral(PI) controllers to efficiently track the reference currents in the d-q domain.It can generate adaptive control actions to compensate the PI controller.The proposed system was simulated under different nonlinear(three-phase full wave rectifier) load conditions.The performance of the proposed approach was compared with the traditional approach.We have also included the simulation results without connecting the traditional PI control based power inverter for reference comparison.The online learning based ADP controller not only reduced average total harmonic distortion by 18.41%,but also outperformed traditional PI controllers during transients.
文摘A novel and simple ifrea! control algorithm using digital signal processor (DSP) has been proposed and realized for a three phase shunt active filter (SAF). The simulation and prototype construction of SAF is conducted to compensate the reactive power and harmonics in a distribution system. The major feature of the proposed ifreal algorithm is that it does not require unit vector templates and any transformations for the reference current genera- tion of SAF. This reduces the computational complexity and makes the control flexible and faster. The simulation is conducted in MATLAB/SIMULINK while DSP TMS320LF2407 is employed in the digital implementation of hysteresis current control (HCC) for experimentation. The hardware results correlate with the simulation results in reducing the total harmonic distortion (THD) of the source current and achieving unity power factor.