Since stack effect that occurs in high-rise buildings has an effect on the indoor environment of the buildings, energy loss and smoke control in case of a fire, there is a need to conduct research on this. For an anal...Since stack effect that occurs in high-rise buildings has an effect on the indoor environment of the buildings, energy loss and smoke control in case of a fire, there is a need to conduct research on this. For an analysis of the stack effect, analysis methods on the leakage flow through gap of interior door shall be formulated. Until now, studies related to the gap leakage flow in buildings have mainly analyzed flow field and pressure in the buildings one-dimensionally using pressure difference-leakage flowrate relations of Orifice Equation and a network numerical analysis algorithm that as- sumes each compartment in the buildings as a single point. In this study, the Momentum Loss Model which enables pressure drop to be proportional to the flow velocity through the gap of door in computational domain of 3-dimensional numerical analysis was proposed to reflect the gap flow phenomenon effectively in 3-dimensional numerical analysis. Using the proposed model, 3-dimensional numerical analysis of the stack effect on the stairs in buildings was performed, and the effects of separation door and lobby between stair and accommodation on the stack effect were investigated.展开更多
The outlet flow fields of a low-speed repeating-stage compressor with bowed stator stages are measured with five-hole probe under the near stall condition when the rotor/stator axial gap varies. The performances of th...The outlet flow fields of a low-speed repeating-stage compressor with bowed stator stages are measured with five-hole probe under the near stall condition when the rotor/stator axial gap varies. The performances of the straight stator stages are investigated and compared to those of the bowed stator stages. The results show that using bowed stator stages could alleviate the flow separation at both upper and low corners of the suction surface and the endwalls, and decrease the losses along the flow passage as well as the outlet flow angle. As the rotor/stator axial gap decreases, although the diffusion capacity of the compressor increases obviously, the outlet flow field in the straight stator stages deteriorates quickly. By contrast, little changes occur in the bowed stator stages, indicating that as the rotor/stator axial gap decreases, improved performance is achieved in the bowed stator stages.展开更多
文摘Since stack effect that occurs in high-rise buildings has an effect on the indoor environment of the buildings, energy loss and smoke control in case of a fire, there is a need to conduct research on this. For an analysis of the stack effect, analysis methods on the leakage flow through gap of interior door shall be formulated. Until now, studies related to the gap leakage flow in buildings have mainly analyzed flow field and pressure in the buildings one-dimensionally using pressure difference-leakage flowrate relations of Orifice Equation and a network numerical analysis algorithm that as- sumes each compartment in the buildings as a single point. In this study, the Momentum Loss Model which enables pressure drop to be proportional to the flow velocity through the gap of door in computational domain of 3-dimensional numerical analysis was proposed to reflect the gap flow phenomenon effectively in 3-dimensional numerical analysis. Using the proposed model, 3-dimensional numerical analysis of the stack effect on the stairs in buildings was performed, and the effects of separation door and lobby between stair and accommodation on the stack effect were investigated.
基金National Natural Science Foundation of China (50646021)Chinese Specialized Research Fund for the Doctoral Pro-gram of Higher Education (20060213007)
文摘The outlet flow fields of a low-speed repeating-stage compressor with bowed stator stages are measured with five-hole probe under the near stall condition when the rotor/stator axial gap varies. The performances of the straight stator stages are investigated and compared to those of the bowed stator stages. The results show that using bowed stator stages could alleviate the flow separation at both upper and low corners of the suction surface and the endwalls, and decrease the losses along the flow passage as well as the outlet flow angle. As the rotor/stator axial gap decreases, although the diffusion capacity of the compressor increases obviously, the outlet flow field in the straight stator stages deteriorates quickly. By contrast, little changes occur in the bowed stator stages, indicating that as the rotor/stator axial gap decreases, improved performance is achieved in the bowed stator stages.