Introduction: Study compare spinal anesthesia using hyperbaric bupivacine (0.5% - 0.75%) between fixed dose and height adjusted dose during elective cesarean section. Methods: Hundred parturients who had given their c...Introduction: Study compare spinal anesthesia using hyperbaric bupivacine (0.5% - 0.75%) between fixed dose and height adjusted dose during elective cesarean section. Methods: Hundred parturients who had given their consent and were scheduled for elective cesarean section under spinal anesthesia, were divided into four groups—first group received 0.5% hyperbaric bupivacine fixed dose, the second group received 0.5% hyperbaric bupivacine in a dose adjusted to the height, the third received 0.75% hyperbaric bupivacine fixed dose, the fourth group received 0.75% hyperbaric bupivacine in a dose adjusted to height. The anesthesia onset time, haemodynamic changes, side effects and fetal outcome observed. Results: Spinal block provide excellent surgical anesthesia in all patients. Anesthesia onset time is longer in adjusted than fixed groups, in 0.5% (5 ± 0.816 vs. 3.84 ± 0.746) (P Conclusion: Adjusting dose of hyperbaric bupivacine (0.5% - 0.75%) to patient’s height, decreases the dose of bupivacine in use, it also provide adequate anesthesia for elective cesarean section with decrease the use of vasopressors, the incidence and severity of maternal hypotention also markedly reduced.展开更多
Silver indium cadmium(Ag–In–Cd) control rod is widely used in pressurized water reactor nuclear power plants,and it is continuously consumed in a high neutron flux environment. The mass ratio of ^(107)Ag in the Ag...Silver indium cadmium(Ag–In–Cd) control rod is widely used in pressurized water reactor nuclear power plants,and it is continuously consumed in a high neutron flux environment. The mass ratio of ^(107)Ag in the Ag–In–Cd control rod is 41.44%. To accurately calculate the consumption value of the control rod, a reliable neutron reaction cross section of the ^(107)Ag is required. Meanwhile,^(107)Ag is also an important weak r nucleus. Thus, the cross sections for neutron induced interactions with ^(107)Ag are very important both in nuclear energy and nuclear astrophysics. The(n, γ) cross section of ^(107)Ag has been measured in the energy range of 1–60 eV using a back streaming white neutron beam line at China spallation neutron source. The resonance parameters are extracted by an R-matrix code. All the cross section of ^(107)Ag and resonance parameters are given in this paper as datasets. The datasets are openly available at http://www.doi.org/10.11922/sciencedb.j00113.00010.展开更多
The neutron capture cross section of 197 Au was measured using the time-of-flight(TOF)technique at the Back-n facility of the China Spallation Neutron Source(CSNS)in the 1 eV to 100 keV range.Prompt c-rays originating...The neutron capture cross section of 197 Au was measured using the time-of-flight(TOF)technique at the Back-n facility of the China Spallation Neutron Source(CSNS)in the 1 eV to 100 keV range.Prompt c-rays originating from neutron-induced capture events were detected by four C_(6)D_(6) liquid scintillator detectors.Pulse height weighting technology(PHWT)was used to analyze the data.The results are in good agreement with ENDF/B-VIII.0,CENDL-3.1,and other evaluated libraries in the resonance region,and in agreement with both n TOF and GELINA experimental data in the 5–100 keV range.Finally,the resonance peaks in the energy range from 1eV to 1 keV were fitted by the SAMMY R-matrix code.展开更多
文摘Introduction: Study compare spinal anesthesia using hyperbaric bupivacine (0.5% - 0.75%) between fixed dose and height adjusted dose during elective cesarean section. Methods: Hundred parturients who had given their consent and were scheduled for elective cesarean section under spinal anesthesia, were divided into four groups—first group received 0.5% hyperbaric bupivacine fixed dose, the second group received 0.5% hyperbaric bupivacine in a dose adjusted to the height, the third received 0.75% hyperbaric bupivacine fixed dose, the fourth group received 0.75% hyperbaric bupivacine in a dose adjusted to height. The anesthesia onset time, haemodynamic changes, side effects and fetal outcome observed. Results: Spinal block provide excellent surgical anesthesia in all patients. Anesthesia onset time is longer in adjusted than fixed groups, in 0.5% (5 ± 0.816 vs. 3.84 ± 0.746) (P Conclusion: Adjusting dose of hyperbaric bupivacine (0.5% - 0.75%) to patient’s height, decreases the dose of bupivacine in use, it also provide adequate anesthesia for elective cesarean section with decrease the use of vasopressors, the incidence and severity of maternal hypotention also markedly reduced.
基金supported by the National Natural Science Foundation of China (Grant Nos. 11875311, 11905274, 1705156, U2032146, 11865010, 11765015, and 1160509)the Natural Science Foundation of Inner Mongolia, China (Grant Nos. 2019JQ01 and 2018MS01009)the Strategic Priority Research Program of the Chinese Academy of Sciences (Grant No. XDB34030000)。
文摘Silver indium cadmium(Ag–In–Cd) control rod is widely used in pressurized water reactor nuclear power plants,and it is continuously consumed in a high neutron flux environment. The mass ratio of ^(107)Ag in the Ag–In–Cd control rod is 41.44%. To accurately calculate the consumption value of the control rod, a reliable neutron reaction cross section of the ^(107)Ag is required. Meanwhile,^(107)Ag is also an important weak r nucleus. Thus, the cross sections for neutron induced interactions with ^(107)Ag are very important both in nuclear energy and nuclear astrophysics. The(n, γ) cross section of ^(107)Ag has been measured in the energy range of 1–60 eV using a back streaming white neutron beam line at China spallation neutron source. The resonance parameters are extracted by an R-matrix code. All the cross section of ^(107)Ag and resonance parameters are given in this paper as datasets. The datasets are openly available at http://www.doi.org/10.11922/sciencedb.j00113.00010.
基金supported by the National Natural Science Foundation of China(Nos.11875311,11905274,11705156,and 11605097)the Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDB34030000)。
文摘The neutron capture cross section of 197 Au was measured using the time-of-flight(TOF)technique at the Back-n facility of the China Spallation Neutron Source(CSNS)in the 1 eV to 100 keV range.Prompt c-rays originating from neutron-induced capture events were detected by four C_(6)D_(6) liquid scintillator detectors.Pulse height weighting technology(PHWT)was used to analyze the data.The results are in good agreement with ENDF/B-VIII.0,CENDL-3.1,and other evaluated libraries in the resonance region,and in agreement with both n TOF and GELINA experimental data in the 5–100 keV range.Finally,the resonance peaks in the energy range from 1eV to 1 keV were fitted by the SAMMY R-matrix code.