A method and system for automatically and simultaneously measuring the light output of multiple scintillators,or each scintillating unit of an array,were developed.Using a large area flat panel PSPMT H8500,the light o...A method and system for automatically and simultaneously measuring the light output of multiple scintillators,or each scintillating unit of an array,were developed.Using a large area flat panel PSPMT H8500,the light output and energy resolution were obtained automatically by comparing with reference scintillators or array using an Energy Table,Look-up Table and energy spectrum data.The aim of developing an efficient performance evaluation of scintillators was achieved.Using the method,a scintillator performance testing system was set up and six LYSO crystals and a 3×3 LYSO array were measured.The results showed that the light output and energy resolution were accurately measured automatically.The deviation of repeat measurements for the same sample was not more than 2%,and the nonlinear deviation of the system was not more than 3%.The system is suitable for measuring the performance of crystals,especially where the mass measurement of crystals and arrays is required.展开更多
In order to meet the increasing demands of modern radiotherapy, real time in-vivo dose measurement has recently attracted significant attention. A small, flexible optical fiber radiation dosimeter, with high signal-to...In order to meet the increasing demands of modern radiotherapy, real time in-vivo dose measurement has recently attracted significant attention. A small, flexible optical fiber radiation dosimeter, with high signal-to-noise ratio (SNR) that employs inorganic scintillator materials is presented. In this paper, some properties are investigated under special conditions, such as saturation properties when the intensity of the X-Ray is increased and the influence of the temperature of the environment. These properties are important to practical considerations if the sensor is to be successfully deployed in-vivo.展开更多
基金Supported by National Natural Science Foundation of China (10805049,11175200)Knowledge Innovation Program of the Chinese Academy of Sciences,Grant (KJCX2-EW-N06)Special-funded Programme on National Key Scientific Instruments and Equipment Development (2011YQ120096)
文摘A method and system for automatically and simultaneously measuring the light output of multiple scintillators,or each scintillating unit of an array,were developed.Using a large area flat panel PSPMT H8500,the light output and energy resolution were obtained automatically by comparing with reference scintillators or array using an Energy Table,Look-up Table and energy spectrum data.The aim of developing an efficient performance evaluation of scintillators was achieved.Using the method,a scintillator performance testing system was set up and six LYSO crystals and a 3×3 LYSO array were measured.The results showed that the light output and energy resolution were accurately measured automatically.The deviation of repeat measurements for the same sample was not more than 2%,and the nonlinear deviation of the system was not more than 3%.The system is suitable for measuring the performance of crystals,especially where the mass measurement of crystals and arrays is required.
文摘In order to meet the increasing demands of modern radiotherapy, real time in-vivo dose measurement has recently attracted significant attention. A small, flexible optical fiber radiation dosimeter, with high signal-to-noise ratio (SNR) that employs inorganic scintillator materials is presented. In this paper, some properties are investigated under special conditions, such as saturation properties when the intensity of the X-Ray is increased and the influence of the temperature of the environment. These properties are important to practical considerations if the sensor is to be successfully deployed in-vivo.