A novel fiber magnetic sensor based on the fiber Bragg grating Fabry-Perot (FBG-FP) cavity ring-down technique with pulse laser injection is proposed and demonstrated theoretically. A general expression of the inten...A novel fiber magnetic sensor based on the fiber Bragg grating Fabry-Perot (FBG-FP) cavity ring-down technique with pulse laser injection is proposed and demonstrated theoretically. A general expression of the intensity of the output electric field is derived, and the effect of the external magnetic field on the ring-down time is discussed. The results show that the output light intensity and the ring-down time of the FBG-FP cavity are in the inverse proportion to the magnitude of the external magnetic field. Our results demonstrate the new concept of the fiber magnetic sensor with the FBG-FP cavity ring-down spectroscopy and the technical feasibility.展开更多
A novel magnetic field sensing system based on the fiber loop ring-down technique is proposed in this paper. In the fiber loop, a U-bent single-mode-fiber structure coated with magnetic fluid(MF) serves as the sensing...A novel magnetic field sensing system based on the fiber loop ring-down technique is proposed in this paper. In the fiber loop, a U-bent single-mode-fiber structure coated with magnetic fluid(MF) serves as the sensing head, and an erbium-doped fiber amplifier(EDFA) is introduced to compensate for the intrinsic loss of the cavity. The ring-down time of the system varies with the change of applied magnetic field due to the tunable absorption coefficient and refractive index of the MF. Therefore, measurement of the magnetic field can be realized by monitoring the ringdown time. The experimental results show that the performance of the system is extremely dependent on the interrogation wavelength, because both the gain of the EDFA and the loss of the sensing head are wavelength dependent.We found that at the optimal wavelength, the ratio of the gain to loss attained its maximum. The sensing system was experimentally demonstrated and a sensitivity of-0.5951 μs∕Oe was achieved.展开更多
Continuous-wave cavity ring-down spectroscopy(CW-CRDS)is an important technical means to monitor greenhouse gases in atmospheric environment.In this paper,a CW-CRDS system is built to meet the needs of atmospheric met...Continuous-wave cavity ring-down spectroscopy(CW-CRDS)is an important technical means to monitor greenhouse gases in atmospheric environment.In this paper,a CW-CRDS system is built to meet the needs of atmospheric methane monitoring.The problem of mode matching is explained from the perspective of transverse mode and longitudinal mode,and the influence of laser injection efficiency on measurement precision is further analyzed.The results of cavity ring-down time measurement show that the measurement precision is higher when the laser is coupled with the fundamental mode.In the experiment,DFB laser is used to calibrate the system with standard methane concentration,and the measurement residual is less than±4×10^(-4)μs^(-1).The methane concentration in the air is monitored in real time for two days.The results show the consistency of the concentration changes over the two days,which further demonstrates the reliability of the system for the measurement of trace methane.By analyzing the influence of mode matching,it not only assists the adjustment of the optical path,but also further improves the sensitivity of the system measurement.展开更多
For the accurate extraction of cavity decay time, a selection of data points is supplemented to the weighted least square method. We derive the expected precision, accuracy and computation cost of this improved method...For the accurate extraction of cavity decay time, a selection of data points is supplemented to the weighted least square method. We derive the expected precision, accuracy and computation cost of this improved method, and examine these performances by simulation. By comparing this method with the nonlinear least square fitting (NLSF) method and the linear regression of the sum (LRS) method in derivations and simulations, we find that this method can achieve the same or even better precision, comparable accuracy, and lower computation cost. We test this method by experimental decay signals. The results are in agreement with the ones obtained from the nonlinear least square fitting method.展开更多
文摘A novel fiber magnetic sensor based on the fiber Bragg grating Fabry-Perot (FBG-FP) cavity ring-down technique with pulse laser injection is proposed and demonstrated theoretically. A general expression of the intensity of the output electric field is derived, and the effect of the external magnetic field on the ring-down time is discussed. The results show that the output light intensity and the ring-down time of the FBG-FP cavity are in the inverse proportion to the magnitude of the external magnetic field. Our results demonstrate the new concept of the fiber magnetic sensor with the FBG-FP cavity ring-down spectroscopy and the technical feasibility.
基金National Key Scientific Instrument and Equipment Development Project of China(2013YQ03091502)National Natural Science Foundation of China(NSFC)(61378043,61107035)
文摘A novel magnetic field sensing system based on the fiber loop ring-down technique is proposed in this paper. In the fiber loop, a U-bent single-mode-fiber structure coated with magnetic fluid(MF) serves as the sensing head, and an erbium-doped fiber amplifier(EDFA) is introduced to compensate for the intrinsic loss of the cavity. The ring-down time of the system varies with the change of applied magnetic field due to the tunable absorption coefficient and refractive index of the MF. Therefore, measurement of the magnetic field can be realized by monitoring the ringdown time. The experimental results show that the performance of the system is extremely dependent on the interrogation wavelength, because both the gain of the EDFA and the loss of the sensing head are wavelength dependent.We found that at the optimal wavelength, the ratio of the gain to loss attained its maximum. The sensing system was experimentally demonstrated and a sensitivity of-0.5951 μs∕Oe was achieved.
基金This research is financial supported by the Natural National Science Foundation of China(Grant Nos.11874364,41877311,and 42005107)the National Key Research and Development Program of China(Grant No.2017YFC0805004)the CAS&Bengbu Technology Transfer Project(Grant No.ZKBB202102).
文摘Continuous-wave cavity ring-down spectroscopy(CW-CRDS)is an important technical means to monitor greenhouse gases in atmospheric environment.In this paper,a CW-CRDS system is built to meet the needs of atmospheric methane monitoring.The problem of mode matching is explained from the perspective of transverse mode and longitudinal mode,and the influence of laser injection efficiency on measurement precision is further analyzed.The results of cavity ring-down time measurement show that the measurement precision is higher when the laser is coupled with the fundamental mode.In the experiment,DFB laser is used to calibrate the system with standard methane concentration,and the measurement residual is less than±4×10^(-4)μs^(-1).The methane concentration in the air is monitored in real time for two days.The results show the consistency of the concentration changes over the two days,which further demonstrates the reliability of the system for the measurement of trace methane.By analyzing the influence of mode matching,it not only assists the adjustment of the optical path,but also further improves the sensitivity of the system measurement.
基金supported by the Preeminent Youth Fund of Sichuan Province,China(Grant No.2012JQ0012)the National Natural Science Foundation of China(Grant Nos.11173008,10974202,and 60978049)the National Key Scientific and Research Equipment Development Project of China(Grant No.ZDYZ2013-2)
文摘For the accurate extraction of cavity decay time, a selection of data points is supplemented to the weighted least square method. We derive the expected precision, accuracy and computation cost of this improved method, and examine these performances by simulation. By comparing this method with the nonlinear least square fitting (NLSF) method and the linear regression of the sum (LRS) method in derivations and simulations, we find that this method can achieve the same or even better precision, comparable accuracy, and lower computation cost. We test this method by experimental decay signals. The results are in agreement with the ones obtained from the nonlinear least square fitting method.