In the study organic-inorganic hybrid composite, epoxy modified silicone coating and vinyl ester flake mastic were comparatively used as several anti-corrosion materials that provided protection for flue gas desulfu-r...In the study organic-inorganic hybrid composite, epoxy modified silicone coating and vinyl ester flake mastic were comparatively used as several anti-corrosion materials that provided protection for flue gas desulfu-rization (FGD). The relationship between curing conversion rate of hybrid polymer and temperature was investigated by differential scanning calorimeter (DSC). The adhesion strength, coefficient of thermal expansion and flame retardant properties of three anti-corrosion materials were measured and analyzed. A corrosion test in 8% H2SO4 and 5% HCl at temperature cycle of 40°C~ 160°C was applied to study corrosion resistance of several anti-corrosion materials. Gravimetric measurement and morphological observation of three materials before and after corrosion test were comparatively analyzed in the paper. The small weight change and good morphological structure of hybrid composite during corrosion test demonstrate that hybrid composite has better anti-corrosion properties than epoxy modified silicone coating and vinyl ester flake mastic.展开更多
The corrosion condition of flue gas desulfurization (FGD) equipment for the coal-fired power plant was defined as the strong corrosion grade. The lining system of hybrid polymer composite was used in internal cylinder...The corrosion condition of flue gas desulfurization (FGD) equipment for the coal-fired power plant was defined as the strong corrosion grade. The lining system of hybrid polymer composite was used in internal cylinder of steel chimney, and a corrosion-resistant and heat-resistant protective layer was formed on the metal surface. The corrosion-resistant and ageing-resistant properties of hybrid polymer composite prepared at low temperature after four years of practical use were investigated by differential scanning calorimeter (DSC), scanning electron microscopy (SEM) and measurement of gravimetric variation, contact angle, abrasion resistance, bonding strength and tensile strength. The properties of hybrid polymer composites prepared at 25℃ and –15℃ were comparatively analyzed in the paper.展开更多
The turbulence kinetic energy and heat transfer performance of air in spirally fluted tube were numerically studied at a constant wall temperature with Reynolds number(Re)between 5000 and 45000.Furthermore,the flow dy...The turbulence kinetic energy and heat transfer performance of air in spirally fluted tube were numerically studied at a constant wall temperature with Reynolds number(Re)between 5000 and 45000.Furthermore,the flow dynamics and heat transfer performance of spirally fluted tubes with five different geometric parameters as well as the effects of separation vortex and swirling wake flow on heat transfer and flow resistance were analyzed.According to the results,heat transfer is enhanced mainly because the fluid hit the windward side of the flute,thus generating a strong turbulence kinetic energy to further reconstruct the boundary layer.The second reason is that the formation of the recirculation zone between the flutes disturbs the boundary layer caused by the flow separation.With the increase of flute depth ratio(L_(d)/D),the separation vortex will become stronger and larger on the leeward side of flute.The separation vortex will break the boundary layer and improve the heat transfer capacity which is accompanied with the increase of fluid resistance.As the flute pitch length ratio(L_(p)/D)decreases,the spiral flow is strengthened,and meanwhile more wake flow is generated.The spiral flow causes little impact on enhancing heat transfer but inhibits the development of the separation vortex and fluid pulsation;in addition,the fluid resistance is reduced at the same time.The maximum value of the average Nusselt number appears when Re=5000,L_(d)/D=0.25 and L_(p)/D=1.00,which is 2.53 times the value of smooth tube.In view of the whole range of Reynolds number,the thermal performance enhancement factor indicates that L_(d)/D=0.15 and L_(p)/D=1.00 are the optimal geometric design parameters.展开更多
文摘In the study organic-inorganic hybrid composite, epoxy modified silicone coating and vinyl ester flake mastic were comparatively used as several anti-corrosion materials that provided protection for flue gas desulfu-rization (FGD). The relationship between curing conversion rate of hybrid polymer and temperature was investigated by differential scanning calorimeter (DSC). The adhesion strength, coefficient of thermal expansion and flame retardant properties of three anti-corrosion materials were measured and analyzed. A corrosion test in 8% H2SO4 and 5% HCl at temperature cycle of 40°C~ 160°C was applied to study corrosion resistance of several anti-corrosion materials. Gravimetric measurement and morphological observation of three materials before and after corrosion test were comparatively analyzed in the paper. The small weight change and good morphological structure of hybrid composite during corrosion test demonstrate that hybrid composite has better anti-corrosion properties than epoxy modified silicone coating and vinyl ester flake mastic.
文摘The corrosion condition of flue gas desulfurization (FGD) equipment for the coal-fired power plant was defined as the strong corrosion grade. The lining system of hybrid polymer composite was used in internal cylinder of steel chimney, and a corrosion-resistant and heat-resistant protective layer was formed on the metal surface. The corrosion-resistant and ageing-resistant properties of hybrid polymer composite prepared at low temperature after four years of practical use were investigated by differential scanning calorimeter (DSC), scanning electron microscopy (SEM) and measurement of gravimetric variation, contact angle, abrasion resistance, bonding strength and tensile strength. The properties of hybrid polymer composites prepared at 25℃ and –15℃ were comparatively analyzed in the paper.
基金This work was supported by the National Key Research and Development Program of China(Grant No.2018YFE0196000)IWHR Basic Scientific Research Projects(No.MK2018J09,No.MK2020J06).
文摘The turbulence kinetic energy and heat transfer performance of air in spirally fluted tube were numerically studied at a constant wall temperature with Reynolds number(Re)between 5000 and 45000.Furthermore,the flow dynamics and heat transfer performance of spirally fluted tubes with five different geometric parameters as well as the effects of separation vortex and swirling wake flow on heat transfer and flow resistance were analyzed.According to the results,heat transfer is enhanced mainly because the fluid hit the windward side of the flute,thus generating a strong turbulence kinetic energy to further reconstruct the boundary layer.The second reason is that the formation of the recirculation zone between the flutes disturbs the boundary layer caused by the flow separation.With the increase of flute depth ratio(L_(d)/D),the separation vortex will become stronger and larger on the leeward side of flute.The separation vortex will break the boundary layer and improve the heat transfer capacity which is accompanied with the increase of fluid resistance.As the flute pitch length ratio(L_(p)/D)decreases,the spiral flow is strengthened,and meanwhile more wake flow is generated.The spiral flow causes little impact on enhancing heat transfer but inhibits the development of the separation vortex and fluid pulsation;in addition,the fluid resistance is reduced at the same time.The maximum value of the average Nusselt number appears when Re=5000,L_(d)/D=0.25 and L_(p)/D=1.00,which is 2.53 times the value of smooth tube.In view of the whole range of Reynolds number,the thermal performance enhancement factor indicates that L_(d)/D=0.15 and L_(p)/D=1.00 are the optimal geometric design parameters.