The annular volute is typically used in a slurry pump to reduce the collisions between solid particles and the volute tongue and to achieve a better resistance to blocking. However, only limited studies regarding annu...The annular volute is typically used in a slurry pump to reduce the collisions between solid particles and the volute tongue and to achieve a better resistance to blocking. However, only limited studies regarding annular volutes are available, and there is no systematic design method for annular volutes. In this study, the influence of volute casing cross-sectional flow area on the hydraulic loss, pressure pulsations, and radial force under varying working conditions in a centrifugal ceramic pump are discussed in detail. Experimental tests were conducted to validate the numerical results. The results indicated that, when the volute casing flow area increases, the hydraulic performance decreases marginally under the rated working conditions, but increases at the o-design points, specifically under large flow condition. However, the volute casing with a larger flow area has a wider high-e ciency region. In addition, the increase in the volute casing flow area will decrease the pressure pulsations in the volute, regardless of the working condition, and decrease the radial force on the shaft, therefore, providing an improved pump operational stability. It is anticipated that this study will be of benefit during the design of annular volutes.展开更多
Statistical analysis of the entrance and wall dynamics of a high-flux gas-solid riser was done using solid concentration time series data collected from a 76 mm internal diameter and 10 m high riser of a CFB system wi...Statistical analysis of the entrance and wall dynamics of a high-flux gas-solid riser was done using solid concentration time series data collected from a 76 mm internal diameter and 10 m high riser of a CFB system with a twin-riser operated at 4.0 to 10.0 m/s gas velocity and 50 to 550 kg/m2s solids flux. Spent fluid catalytic cracking catalyst particles with 67 μm mean diameter and density of 1500 kg/m3 together with 70% to 80% humid air was used. Solid concentration data were analysed using code prepared using FORTRAN 2008 to get statistical parameters and plot their profiles. Results obtained show that the gas-solid suspension flow in the riser is dominated by low solid concentration in the centre region and high solid concentration in the wall region which forms a core-annulus flow structure. The mean solid concentration in the wall region decreases with riser height from the dense bottom section to less dense in the fully developed flow section at the top of the riser. The gas-solid suspension flow in the centre region is dominated with uniform flow structure while the wall region is dominated with high fluctuations in solid concentration. Further, it was found that the entrance and developing flow sections of the riser exhibit high flow non-uniformities than the fully developed flow section of the riser. The flow non-uniformities in the entrance and developing flow section increase with increase in superficial gas velocity at constant solid flux. The wall region, from the entrance to the top sections of the riser along the axial direction exhibits both dilute and dense suspension flow.展开更多
基金Supported by National Natural Science Foundation of China(Grant No.51779107)Jiangsu Provincial Natural Science Foundation of China(Grant No.BK20170548)+1 种基金Postdoctoral Science Foundation of China(Grant No.2017M611724)Priority Academic Program Development of Jiangsu Higher Education Institutions(PAPD)
文摘The annular volute is typically used in a slurry pump to reduce the collisions between solid particles and the volute tongue and to achieve a better resistance to blocking. However, only limited studies regarding annular volutes are available, and there is no systematic design method for annular volutes. In this study, the influence of volute casing cross-sectional flow area on the hydraulic loss, pressure pulsations, and radial force under varying working conditions in a centrifugal ceramic pump are discussed in detail. Experimental tests were conducted to validate the numerical results. The results indicated that, when the volute casing flow area increases, the hydraulic performance decreases marginally under the rated working conditions, but increases at the o-design points, specifically under large flow condition. However, the volute casing with a larger flow area has a wider high-e ciency region. In addition, the increase in the volute casing flow area will decrease the pressure pulsations in the volute, regardless of the working condition, and decrease the radial force on the shaft, therefore, providing an improved pump operational stability. It is anticipated that this study will be of benefit during the design of annular volutes.
文摘Statistical analysis of the entrance and wall dynamics of a high-flux gas-solid riser was done using solid concentration time series data collected from a 76 mm internal diameter and 10 m high riser of a CFB system with a twin-riser operated at 4.0 to 10.0 m/s gas velocity and 50 to 550 kg/m2s solids flux. Spent fluid catalytic cracking catalyst particles with 67 μm mean diameter and density of 1500 kg/m3 together with 70% to 80% humid air was used. Solid concentration data were analysed using code prepared using FORTRAN 2008 to get statistical parameters and plot their profiles. Results obtained show that the gas-solid suspension flow in the riser is dominated by low solid concentration in the centre region and high solid concentration in the wall region which forms a core-annulus flow structure. The mean solid concentration in the wall region decreases with riser height from the dense bottom section to less dense in the fully developed flow section at the top of the riser. The gas-solid suspension flow in the centre region is dominated with uniform flow structure while the wall region is dominated with high fluctuations in solid concentration. Further, it was found that the entrance and developing flow sections of the riser exhibit high flow non-uniformities than the fully developed flow section of the riser. The flow non-uniformities in the entrance and developing flow section increase with increase in superficial gas velocity at constant solid flux. The wall region, from the entrance to the top sections of the riser along the axial direction exhibits both dilute and dense suspension flow.