This paper addresses the control design and the experimental validation of a current mode control for a three phase voltage source rectifier. The proposed control law is able to fulfill the voltage regulation and the ...This paper addresses the control design and the experimental validation of a current mode control for a three phase voltage source rectifier. The proposed control law is able to fulfill the voltage regulation and the current tracking control objectives despite of unbalanced and distorted grid voltages. The proposed control law consists of two loops, which are referred as inner tracking loop and the outer voltage regulation loop. The inner loop is designed to provide damping to the system, which also includes and adaptive mechanism. The construction of the current reference is based on the positive component detection of thegrid voltage. Therefore, the current produced by the power rectifier is proportional to the fundamental component of the grid voltage, despite of the presence of unbalanced grid voltages. The voltage regulation loop is designed as a proportional-integral controller, which is aimed to regulate the DC output voltage to a desired level. Finally, experimental results are obtained in an experimental prototype of2 kW to evaluate the performance of the proposed controller.展开更多
The improved current-doubler-rectifier zero-voltage-switching PWM full-bridge converter (CDR ZVS PWM FB converter) achieves ZVS for the switches in a wide load range with the use of the energy stored in the output fil...The improved current-doubler-rectifier zero-voltage-switching PWM full-bridge converter (CDR ZVS PWM FB converter) achieves ZVS for the switches in a wide load range with the use of the energy stored in the output filter inductances, and the rectifier diodes commute naturally, therefore no oscillation and voltage spike occurs. The transformer needs no special manufacture method to limit the leakage inductance. The ZVS achievement and the design considerations for the output filter inductances and the blocking capacitor are discussed for the improved CDR ZVS PWM FB converter. A 540 W prototype converter is built in the lab to verify the operational principle and design considerations for the improved converter, the experimental results are also included.展开更多
文摘This paper addresses the control design and the experimental validation of a current mode control for a three phase voltage source rectifier. The proposed control law is able to fulfill the voltage regulation and the current tracking control objectives despite of unbalanced and distorted grid voltages. The proposed control law consists of two loops, which are referred as inner tracking loop and the outer voltage regulation loop. The inner loop is designed to provide damping to the system, which also includes and adaptive mechanism. The construction of the current reference is based on the positive component detection of thegrid voltage. Therefore, the current produced by the power rectifier is proportional to the fundamental component of the grid voltage, despite of the presence of unbalanced grid voltages. The voltage regulation loop is designed as a proportional-integral controller, which is aimed to regulate the DC output voltage to a desired level. Finally, experimental results are obtained in an experimental prototype of2 kW to evaluate the performance of the proposed controller.
文摘The improved current-doubler-rectifier zero-voltage-switching PWM full-bridge converter (CDR ZVS PWM FB converter) achieves ZVS for the switches in a wide load range with the use of the energy stored in the output filter inductances, and the rectifier diodes commute naturally, therefore no oscillation and voltage spike occurs. The transformer needs no special manufacture method to limit the leakage inductance. The ZVS achievement and the design considerations for the output filter inductances and the blocking capacitor are discussed for the improved CDR ZVS PWM FB converter. A 540 W prototype converter is built in the lab to verify the operational principle and design considerations for the improved converter, the experimental results are also included.