As a combination device for a step-up pulse transformer and a magnetic switch,the saturable pulse transformer is widely used in pulsed-power and plasma technology.A fractional-turn ratio saturable pulse transformer is...As a combination device for a step-up pulse transformer and a magnetic switch,the saturable pulse transformer is widely used in pulsed-power and plasma technology.A fractional-turn ratio saturable pulse transformer is constructed and analyzed in this paper.Preliminary experimental results show that if the primary energy storage capacitors are charged to 300 V,an output voltage of about 19 kV can be obtained across the capacitor connected to the secondary windings of a fractional-tum ratio saturable pulse transformer.Theoretical and experimental results reveal that this kind of pulse transformer is not only able to integrate a step-up transformer and a magnetic switch into one device,but can also lower the saturable inductance of its secondary windings,thus leading to the relatively high step-up ratio of the pulse transformer.Meanwhile,the application of the fractional-turn ratio saturable pulse transformer in a μs range pulse modulator as a voltage step-up device and main switch is also included in this paper.The demonstrated experiments display that an output voltage with an amplitude of about 29 kV,and a 1.6 μs pulse width can be obtained across a 3500 Ω resistive load,based on a pulse modulator,if the primary energy storage capacitors are charged to 300 V.This compact fractional-turn ratio saturable pulse transformer can be applied in many other fields such as surface treatment,corona plasma generation and dielectric barrier discharge.展开更多
A C-band accelerator structure was used to accelerate electrons at the Shanghai soft X-ray free-electron laser test facility (SXFEL-TF) in Shanghai Institute of Applied Physics (SINAP). The microwave system of this ac...A C-band accelerator structure was used to accelerate electrons at the Shanghai soft X-ray free-electron laser test facility (SXFEL-TF) in Shanghai Institute of Applied Physics (SINAP). The microwave system of this accelerator structure used a 110 MW pulse modulator and a klystron (PV-5050) to provide the power supply. A pulse transformer is a crucial device in a modulator klystron system and plays significant roles in voltage level transformation, matching impedances, and polarity inversion. This study presents the optimization of a high-voltage pulse transformer. The design considerations of reducing flattop ringing and flattop droop, and shortening leading edge are provided. The model simulation, mechanical design, and the relevant experimental results are also presented.展开更多
设计采用反馈控制的方法改善脉冲调制器输出高压脉冲幅度稳定性,分析了实现稳定性目标对数据采集系统软、硬件的要求,介绍了相关的实验测试和信号处理方法。数据采集系统由Stratix ii FPGA开发板、AD6645、上位PC机组成,借用差分放大器...设计采用反馈控制的方法改善脉冲调制器输出高压脉冲幅度稳定性,分析了实现稳定性目标对数据采集系统软、硬件的要求,介绍了相关的实验测试和信号处理方法。数据采集系统由Stratix ii FPGA开发板、AD6645、上位PC机组成,借用差分放大器提高测量分辨率。数据处理采用脉冲采样样本均值作为表征幅度的特征量,并采用平均、插值、数字滤波、BP神经网络等方法来提高幅度监测值的分辨率能力和抗干扰能力。展开更多
基金supported by National Natural Science Foundation of China under Grant Nos.51477177 and 51641707
文摘As a combination device for a step-up pulse transformer and a magnetic switch,the saturable pulse transformer is widely used in pulsed-power and plasma technology.A fractional-turn ratio saturable pulse transformer is constructed and analyzed in this paper.Preliminary experimental results show that if the primary energy storage capacitors are charged to 300 V,an output voltage of about 19 kV can be obtained across the capacitor connected to the secondary windings of a fractional-tum ratio saturable pulse transformer.Theoretical and experimental results reveal that this kind of pulse transformer is not only able to integrate a step-up transformer and a magnetic switch into one device,but can also lower the saturable inductance of its secondary windings,thus leading to the relatively high step-up ratio of the pulse transformer.Meanwhile,the application of the fractional-turn ratio saturable pulse transformer in a μs range pulse modulator as a voltage step-up device and main switch is also included in this paper.The demonstrated experiments display that an output voltage with an amplitude of about 29 kV,and a 1.6 μs pulse width can be obtained across a 3500 Ω resistive load,based on a pulse modulator,if the primary energy storage capacitors are charged to 300 V.This compact fractional-turn ratio saturable pulse transformer can be applied in many other fields such as surface treatment,corona plasma generation and dielectric barrier discharge.
基金supported by the National Natural Science Foundation of China(No.11675250)
文摘A C-band accelerator structure was used to accelerate electrons at the Shanghai soft X-ray free-electron laser test facility (SXFEL-TF) in Shanghai Institute of Applied Physics (SINAP). The microwave system of this accelerator structure used a 110 MW pulse modulator and a klystron (PV-5050) to provide the power supply. A pulse transformer is a crucial device in a modulator klystron system and plays significant roles in voltage level transformation, matching impedances, and polarity inversion. This study presents the optimization of a high-voltage pulse transformer. The design considerations of reducing flattop ringing and flattop droop, and shortening leading edge are provided. The model simulation, mechanical design, and the relevant experimental results are also presented.
文摘设计采用反馈控制的方法改善脉冲调制器输出高压脉冲幅度稳定性,分析了实现稳定性目标对数据采集系统软、硬件的要求,介绍了相关的实验测试和信号处理方法。数据采集系统由Stratix ii FPGA开发板、AD6645、上位PC机组成,借用差分放大器提高测量分辨率。数据处理采用脉冲采样样本均值作为表征幅度的特征量,并采用平均、插值、数字滤波、BP神经网络等方法来提高幅度监测值的分辨率能力和抗干扰能力。