It is widely recognized that nonlinear time-history analysis constitutes the most accurate way to simulate the response of structures subjected to strong levels of seismic excitation. This analytical method is based o...It is widely recognized that nonlinear time-history analysis constitutes the most accurate way to simulate the response of structures subjected to strong levels of seismic excitation. This analytical method is based on sound underlying principles and has the capability to reproduce the intrinsic inelastic dynamic behavior of structures. Nonetheless, comparisons with experimental results from large-scale testing of structures are still needed, in order to ensure adequate levels of confidence in this numerical methodology. The fiber modelling approach employed in the current endeavor inherently accounts for geometric nonlinearities and material inelasticity, without a need for calibration of plastic hinges mechanisms, typical in concentrated plasticity models. The resulting combination of analysis accuracy and modelling simplicity, allows thus to overcome the perhaps not fully justifiable sense of complexity associated to nonlinear dynamic analysis. The fiber-based modelling approach is employed in the framework of a finite element program downloaded from the Intemet for seismic response analysis of framed structures. The reliability and accuracy of the program are demonstrated by numerically reproducing pseudo-dynamic tests on a four span continuous deck concrete bridge. Modelling assumptions are discussed, together with their implications on numerical results of the nonlinear time-history analyses, which were found to be in good agreement with experimental results.展开更多
This paper describes a commonly used pseudo-static method in seismic resistant design of the cross section of underground structures. Based on dynamic theory and the vibration characteristics of underground structures...This paper describes a commonly used pseudo-static method in seismic resistant design of the cross section of underground structures. Based on dynamic theory and the vibration characteristics of underground structures, the sources of errors when using this method are analyzed. The traditional seismic motion loading approach is replaced by a method in which a one-dimensional soil layer response stress is differentiated and then converted into seismic live loads. To validate the improved method, a comparison of analytical results is conducted for internal forces under earthquake shaking of a typical shallow embedded box-shaped subway station structure using four methods: the response displacement method, finite element response acceleration method, the finite element dynamic analysis method and the improved pseudo-static calculation method. It is shown that the improved finite element pseudo-static method proposed in this paper provides an effective tool for the seismic design of underground structures. The evaluation yields results close to those obtained by the finite element dynamic analysis method, and shows that the improved finite element pseudo-static method provides a higher degree of precision.展开更多
文摘It is widely recognized that nonlinear time-history analysis constitutes the most accurate way to simulate the response of structures subjected to strong levels of seismic excitation. This analytical method is based on sound underlying principles and has the capability to reproduce the intrinsic inelastic dynamic behavior of structures. Nonetheless, comparisons with experimental results from large-scale testing of structures are still needed, in order to ensure adequate levels of confidence in this numerical methodology. The fiber modelling approach employed in the current endeavor inherently accounts for geometric nonlinearities and material inelasticity, without a need for calibration of plastic hinges mechanisms, typical in concentrated plasticity models. The resulting combination of analysis accuracy and modelling simplicity, allows thus to overcome the perhaps not fully justifiable sense of complexity associated to nonlinear dynamic analysis. The fiber-based modelling approach is employed in the framework of a finite element program downloaded from the Intemet for seismic response analysis of framed structures. The reliability and accuracy of the program are demonstrated by numerically reproducing pseudo-dynamic tests on a four span continuous deck concrete bridge. Modelling assumptions are discussed, together with their implications on numerical results of the nonlinear time-history analyses, which were found to be in good agreement with experimental results.
基金China Earthquake Administration Association Fund Under Grant No. 106060 and Institute of Engineering Mechanics Director Fund
文摘This paper describes a commonly used pseudo-static method in seismic resistant design of the cross section of underground structures. Based on dynamic theory and the vibration characteristics of underground structures, the sources of errors when using this method are analyzed. The traditional seismic motion loading approach is replaced by a method in which a one-dimensional soil layer response stress is differentiated and then converted into seismic live loads. To validate the improved method, a comparison of analytical results is conducted for internal forces under earthquake shaking of a typical shallow embedded box-shaped subway station structure using four methods: the response displacement method, finite element response acceleration method, the finite element dynamic analysis method and the improved pseudo-static calculation method. It is shown that the improved finite element pseudo-static method proposed in this paper provides an effective tool for the seismic design of underground structures. The evaluation yields results close to those obtained by the finite element dynamic analysis method, and shows that the improved finite element pseudo-static method provides a higher degree of precision.