Capillary columns are used in both capillary liquid chromatography and capillary electrochromatography. The design for capillary liquid chromatography is discussed in comparison with capillary gas chromatography. The ...Capillary columns are used in both capillary liquid chromatography and capillary electrochromatography. The design for capillary liquid chromatography is discussed in comparison with capillary gas chromatography. The difference of diffusion coefficient in gas and liquid phase is a key role. The study for obtaining a high performance capillary liquid chromatography is discussed. Capillary electrochromatography is recently interesting for its instinct ability to realize a high performance chromatography. Capillary electrochromatography with and without pressurized flow is reviewed briefly. Instrumentation for capillary electrochromatography with pressurized flow is discussed. The port of splitting, and gradient elution of both solution and potential are described. The new findings of both the variation of column resistance and capacity factor according to the value of applied electric voltage are also discussed.展开更多
A novel monolithic stationary phase with long alkyl chain ligands was introduced and evaluated in pressurized capillary electrochromatography(p-CEC) by using a mixture of neutral and charged compounds. The capillary m...A novel monolithic stationary phase with long alkyl chain ligands was introduced and evaluated in pressurized capillary electrochromatography(p-CEC) by using a mixture of neutral and charged compounds. The capillary monolithic-column was prepared by in situ copolymerization of ethylene dimethacrylate,alkyl alcohol and 2-acrylamido-2-methyl-1-propanesulfonic acid in a quadruple porogenic solvent consisting of 1,4-butanediol/cyclohexanol/docecanol/water. Effects of experimental parameters in p-CEC,such as pressure and electrical field strength,on the separation were investigated. The baseline separation of the components in the mixture was achieved. The monolithic column can be used as an alternative to the conventional capillary column such as the reversed phase ODS.展开更多
文摘Capillary columns are used in both capillary liquid chromatography and capillary electrochromatography. The design for capillary liquid chromatography is discussed in comparison with capillary gas chromatography. The difference of diffusion coefficient in gas and liquid phase is a key role. The study for obtaining a high performance capillary liquid chromatography is discussed. Capillary electrochromatography is recently interesting for its instinct ability to realize a high performance chromatography. Capillary electrochromatography with and without pressurized flow is reviewed briefly. Instrumentation for capillary electrochromatography with pressurized flow is discussed. The port of splitting, and gradient elution of both solution and potential are described. The new findings of both the variation of column resistance and capacity factor according to the value of applied electric voltage are also discussed.
文摘A novel monolithic stationary phase with long alkyl chain ligands was introduced and evaluated in pressurized capillary electrochromatography(p-CEC) by using a mixture of neutral and charged compounds. The capillary monolithic-column was prepared by in situ copolymerization of ethylene dimethacrylate,alkyl alcohol and 2-acrylamido-2-methyl-1-propanesulfonic acid in a quadruple porogenic solvent consisting of 1,4-butanediol/cyclohexanol/docecanol/water. Effects of experimental parameters in p-CEC,such as pressure and electrical field strength,on the separation were investigated. The baseline separation of the components in the mixture was achieved. The monolithic column can be used as an alternative to the conventional capillary column such as the reversed phase ODS.