Observation of the low-frequency oscillation (LFO) modes in power systems is important to design the damping scheme. The state equations of the power system with the doubly-fed induction generators (DFIGs) are derived...Observation of the low-frequency oscillation (LFO) modes in power systems is important to design the damping scheme. The state equations of the power system with the doubly-fed induction generators (DFIGs) are derived to find the LFO modes related to the synchronous generator (SGs) and the DFIGs. The definition of the observability measure is improved to consider the initial output and the attenuation speed of the modes. The sensitivities of the observability measures to the control parameters are derived. The numerical results from the small and large-disturbance validate the LFO modes caused by the DFIGs, and different observability measures are compared. Adjustment of the control parameters is chosen based on the sensitivity model to improve the observability and damping ratio of the LFO mode, and the stability of the wind power system.展开更多
Microgrid stability analysis is a critical issue especially due to the inverters’low-inertia nature.The voltage and current control loops influences on stability are researched frequently most of which focus on mediu...Microgrid stability analysis is a critical issue especially due to the inverters’low-inertia nature.The voltage and current control loops influences on stability are researched frequently most of which focus on medium and high-frequency characteristic.Although the complete state-space model aims at low-frequency characteristic,it is too complicated and the calculation amount is huge with the scale of the microgrid increasing.One available reduced-order model of an inverter is simple,but it is suitable for only single inverter without network dynamic in microgrid.To fill in these gaps,a novel modeling method is proposed in this paper to investigate the low-frequency instability phenomenon and describe the whole DG connected system including network.In consideration of the high penetration level of induction motor(IM)loads and constant power(CP)loads in practical applications,the low-frequency mathematical model of IM and CP loads on the basis of static load is also built in this paper.Simulation and experimental results verify the effectiveness of the proposed model.展开更多
基金This work was supported by the National Natural Science Foundation of China(Grant No.51877061).
文摘Observation of the low-frequency oscillation (LFO) modes in power systems is important to design the damping scheme. The state equations of the power system with the doubly-fed induction generators (DFIGs) are derived to find the LFO modes related to the synchronous generator (SGs) and the DFIGs. The definition of the observability measure is improved to consider the initial output and the attenuation speed of the modes. The sensitivities of the observability measures to the control parameters are derived. The numerical results from the small and large-disturbance validate the LFO modes caused by the DFIGs, and different observability measures are compared. Adjustment of the control parameters is chosen based on the sensitivity model to improve the observability and damping ratio of the LFO mode, and the stability of the wind power system.
基金This work was supported by the National key research and development plan 2016YFB0900300National Natural Science Foundation of China under Grant51677162Natural Science Foundation of Hebei Province E2017203337。
文摘Microgrid stability analysis is a critical issue especially due to the inverters’low-inertia nature.The voltage and current control loops influences on stability are researched frequently most of which focus on medium and high-frequency characteristic.Although the complete state-space model aims at low-frequency characteristic,it is too complicated and the calculation amount is huge with the scale of the microgrid increasing.One available reduced-order model of an inverter is simple,but it is suitable for only single inverter without network dynamic in microgrid.To fill in these gaps,a novel modeling method is proposed in this paper to investigate the low-frequency instability phenomenon and describe the whole DG connected system including network.In consideration of the high penetration level of induction motor(IM)loads and constant power(CP)loads in practical applications,the low-frequency mathematical model of IM and CP loads on the basis of static load is also built in this paper.Simulation and experimental results verify the effectiveness of the proposed model.