To evaluate the bioeompatibility of MIM 316L stainless steel,the percentage of S-period cells were detected by flow cytometry after L929 incubated with extraction of MIM 316L stainless steel,using titanium implant mat...To evaluate the bioeompatibility of MIM 316L stainless steel,the percentage of S-period cells were detected by flow cytometry after L929 incubated with extraction of MIM 316L stainless steel,using titanium implant materials of clinical application as the contrast.Both materials were implanted in animal and the histopathological evaluations were carried out.The statistical analyses show that there are no significant differences between two groups(P>0.05),which demonstrates that MIM 316L stainless steel has a good biocompatibility.展开更多
The solvent debinding of water soluble binder in powder injection moulding (MIM) was investigated systematically, including the effects of solvent types, temperature and the thickness of green parts on the solvent deb...The solvent debinding of water soluble binder in powder injection moulding (MIM) was investigated systematically, including the effects of solvent types, temperature and the thickness of green parts on the solvent debinding rate. After studying the debinding of a green part with a thickness of 4.26 mm, it was found that, the debinding rate of polyethylene glycol(PEG) in water and alcohol was high initially, and then decreased; however, it would increase with temperature increasing. At room temperature, the dissolution rate of PEG in water was higher than that in alcohol, but the latter would be much faster with temperature increasing because the debinding activation energy in alcohol was 51.44 kJ·mol -1 ·K -1 , much higher than 24.23 kJ·mol -1 ·K -1 in water. With a green part thickness larger than 4.26 mm, the debinding was controlled by diffusion; but with that smaller than 2.36 mm, the debinding was controlled by both dissolution and diffusion.展开更多
基金Project(2003AA302210)supported by the National Hi-tech Research Prograrm of Chinap.
文摘To evaluate the bioeompatibility of MIM 316L stainless steel,the percentage of S-period cells were detected by flow cytometry after L929 incubated with extraction of MIM 316L stainless steel,using titanium implant materials of clinical application as the contrast.Both materials were implanted in animal and the histopathological evaluations were carried out.The statistical analyses show that there are no significant differences between two groups(P>0.05),which demonstrates that MIM 316L stainless steel has a good biocompatibility.
文摘The solvent debinding of water soluble binder in powder injection moulding (MIM) was investigated systematically, including the effects of solvent types, temperature and the thickness of green parts on the solvent debinding rate. After studying the debinding of a green part with a thickness of 4.26 mm, it was found that, the debinding rate of polyethylene glycol(PEG) in water and alcohol was high initially, and then decreased; however, it would increase with temperature increasing. At room temperature, the dissolution rate of PEG in water was higher than that in alcohol, but the latter would be much faster with temperature increasing because the debinding activation energy in alcohol was 51.44 kJ·mol -1 ·K -1 , much higher than 24.23 kJ·mol -1 ·K -1 in water. With a green part thickness larger than 4.26 mm, the debinding was controlled by diffusion; but with that smaller than 2.36 mm, the debinding was controlled by both dissolution and diffusion.