Purpose: To establish a HPLC testing method of the content of bulk picoplatin and its impurities. Method: the separation was perform on a C18 column(4.6 mm×250 mm, 5 m) with potassium dihydrogen phosphate-aceton-...Purpose: To establish a HPLC testing method of the content of bulk picoplatin and its impurities. Method: the separation was perform on a C18 column(4.6 mm×250 mm, 5 m) with potassium dihydrogen phosphate-aceton-itrile as the mobile phase at a flow rate of 1.0 mL/min. The detecting wavelength was set at 210 nm, and the column temperature was set at 30℃. Result: in the method validation, the linear relationship modulus of picoplatin is 0.9999, the systemic precision is 0.44%, the method precision is 0.74%, the average recovery rate is 99.62%, the LOD and LOQ of picoplatin is 0.2 ng and 1.0 ng. The average resolution of picoplatin and its impurities is more than 2. Conclusion: The established method is good specificity, high sensitivity, and good repeatability which could provide scientific evidence for the quality control of picoplatin and its impurities.展开更多
文摘Purpose: To establish a HPLC testing method of the content of bulk picoplatin and its impurities. Method: the separation was perform on a C18 column(4.6 mm×250 mm, 5 m) with potassium dihydrogen phosphate-aceton-itrile as the mobile phase at a flow rate of 1.0 mL/min. The detecting wavelength was set at 210 nm, and the column temperature was set at 30℃. Result: in the method validation, the linear relationship modulus of picoplatin is 0.9999, the systemic precision is 0.44%, the method precision is 0.74%, the average recovery rate is 99.62%, the LOD and LOQ of picoplatin is 0.2 ng and 1.0 ng. The average resolution of picoplatin and its impurities is more than 2. Conclusion: The established method is good specificity, high sensitivity, and good repeatability which could provide scientific evidence for the quality control of picoplatin and its impurities.