In order to overcome the inconvenience of manual bubble counting, a bubble counter based on photoelectric technique aiming for automatically detecting and measuring minute gas leakage of cryogenic valves is proposed. ...In order to overcome the inconvenience of manual bubble counting, a bubble counter based on photoelectric technique aiming for automatically detecting and measuring minute gas leakage of cryogenic valves is proposed. Experiments have been conducted on a self-built apparatus, testing the performance with different gas inlet strategies (bottom gas-inlet strategy and side gas-inlet strategy) and the influence of gas pipe length (0, 1, 2, 4, 6, 8, 10 m) and leakage rate (around 10, 20, 30, 40 bubbles/min) on first bubble time and bubble rate. A buffer of 110 cm3 is inserted between leakage source and gas pipe to simulate the down- stream cavum adjacent to the valve clack. Based on analyzing the experimental data, experiential parameters have also been summarized to guide leakage detection and measurement for engineering applications. A practical system has already been suc- cessfully applied in a cryogenic testing apparatus for cryogenic valves.展开更多
The oligo phenylene vinylene(oligo PV)/SiO 2 composite film was prepared by the sol gel process. The surface photovoltage spectroscopy(SPS) and electric field induced surface photovoltage spectroscopy(EFISPS) had been...The oligo phenylene vinylene(oligo PV)/SiO 2 composite film was prepared by the sol gel process. The surface photovoltage spectroscopy(SPS) and electric field induced surface photovoltage spectroscopy(EFISPS) had been used to investigate the charge transport process in olige PV/SiO 2 heterostructured composite. The results show that the oligo PV / SiO 2 composite film not only can improve the stability of oligo PV, but also have some photoelectric activity.展开更多
基金Project (Nos. 50776075 and 50536040) supported by the National Natural Science Foundation of China
文摘In order to overcome the inconvenience of manual bubble counting, a bubble counter based on photoelectric technique aiming for automatically detecting and measuring minute gas leakage of cryogenic valves is proposed. Experiments have been conducted on a self-built apparatus, testing the performance with different gas inlet strategies (bottom gas-inlet strategy and side gas-inlet strategy) and the influence of gas pipe length (0, 1, 2, 4, 6, 8, 10 m) and leakage rate (around 10, 20, 30, 40 bubbles/min) on first bubble time and bubble rate. A buffer of 110 cm3 is inserted between leakage source and gas pipe to simulate the down- stream cavum adjacent to the valve clack. Based on analyzing the experimental data, experiential parameters have also been summarized to guide leakage detection and measurement for engineering applications. A practical system has already been suc- cessfully applied in a cryogenic testing apparatus for cryogenic valves.
文摘The oligo phenylene vinylene(oligo PV)/SiO 2 composite film was prepared by the sol gel process. The surface photovoltage spectroscopy(SPS) and electric field induced surface photovoltage spectroscopy(EFISPS) had been used to investigate the charge transport process in olige PV/SiO 2 heterostructured composite. The results show that the oligo PV / SiO 2 composite film not only can improve the stability of oligo PV, but also have some photoelectric activity.