Based on the theory of the passive hydrogen maser, along with the technology of frequency modulation and modulation transfer spectroscopy, the theoretical expression of the single frequency modulation for the passive ...Based on the theory of the passive hydrogen maser, along with the technology of frequency modulation and modulation transfer spectroscopy, the theoretical expression of the single frequency modulation for the passive hydrogen maser and the function of the cavity and H line error signals separation are derived, which are basically coincident with the experiment. The absorption and dispersion spectrum curves with different resonance widths show that the cavity and hydrogen transition serve as discriminators, and the two error signals can be separated. Through the calculations of the two error signals in the passive hydrogen maser, it analyzes the traditional method of the two error signals separation, and then describes a new improved method for the passive hydrogen servo loops consisting in the use of a single modulation frequency and frequency discrimination. A null interaction of the two error signals for the new selection of the phase setting is deduced theoretically and validated by the simulation. The preliminary experimental result confirms the feasibility of this new approach, which can reduce the influence from the cavity frequency variety on the crystal oscillator and contribute significantly to the long term performance of the passive hydrogen maser.展开更多
Based on the operating principle and the electric property design of the passive hydrogen maser, the technology and test results of its space adaptability are carried out under the special launch conditions and space ...Based on the operating principle and the electric property design of the passive hydrogen maser, the technology and test results of its space adaptability are carried out under the special launch conditions and space environment. The various perturbations affecting the output frequency of such a standard used for the navigation satellite system are specified, such as magnetic field change, vibration, thermal vacuum and radiation. Through the adaptability technology in the aspects above, the security and reliability of the space passive hydrogen maser sufficiently fulfill the requirements of space operation. At present, the space passive hydrogen maser is working normally on board, indicating that the space adaptability satisfies the design requirement.展开更多
中国计划于2025年左右建立月球轨道VLBI(Very Long Baseline Interferometer)测站,将会搭载被动型星载氢钟作为时间频率标准.由于是首次在VLBI观测中使用星载氢钟,需要研究和验证其可行性.因此,利用星载氢钟作为频率基准开展了VLBI观测...中国计划于2025年左右建立月球轨道VLBI(Very Long Baseline Interferometer)测站,将会搭载被动型星载氢钟作为时间频率标准.由于是首次在VLBI观测中使用星载氢钟,需要研究和验证其可行性.因此,利用星载氢钟作为频率基准开展了VLBI观测.实验时,分别使用主动型地面氢钟和被动型星载氢钟作为频率基准,利用上海天文台佘山25m射电望远镜和其他测站对我国火星探测器天问一号进行了交替VLBI观测.数据处理分析结果表明,基于地面氢钟与星载氢钟的VLBI残余群时延标准差均在0.5ns以内,表明星载氢钟可满足深空探测VLBI测定轨的精度要求,验证了其作为月球VLBI测站频率基准的可行性.展开更多
基金supported by the Next Generation of Beidou Navigation Satellite(GFZX0301020104)
文摘Based on the theory of the passive hydrogen maser, along with the technology of frequency modulation and modulation transfer spectroscopy, the theoretical expression of the single frequency modulation for the passive hydrogen maser and the function of the cavity and H line error signals separation are derived, which are basically coincident with the experiment. The absorption and dispersion spectrum curves with different resonance widths show that the cavity and hydrogen transition serve as discriminators, and the two error signals can be separated. Through the calculations of the two error signals in the passive hydrogen maser, it analyzes the traditional method of the two error signals separation, and then describes a new improved method for the passive hydrogen servo loops consisting in the use of a single modulation frequency and frequency discrimination. A null interaction of the two error signals for the new selection of the phase setting is deduced theoretically and validated by the simulation. The preliminary experimental result confirms the feasibility of this new approach, which can reduce the influence from the cavity frequency variety on the crystal oscillator and contribute significantly to the long term performance of the passive hydrogen maser.
基金supported by the Next Generation of Beidou Navigation Satellite(the Space Passive Hydrogen Maser Technology,GFZX0301020104)
文摘Based on the operating principle and the electric property design of the passive hydrogen maser, the technology and test results of its space adaptability are carried out under the special launch conditions and space environment. The various perturbations affecting the output frequency of such a standard used for the navigation satellite system are specified, such as magnetic field change, vibration, thermal vacuum and radiation. Through the adaptability technology in the aspects above, the security and reliability of the space passive hydrogen maser sufficiently fulfill the requirements of space operation. At present, the space passive hydrogen maser is working normally on board, indicating that the space adaptability satisfies the design requirement.
文摘中国计划于2025年左右建立月球轨道VLBI(Very Long Baseline Interferometer)测站,将会搭载被动型星载氢钟作为时间频率标准.由于是首次在VLBI观测中使用星载氢钟,需要研究和验证其可行性.因此,利用星载氢钟作为频率基准开展了VLBI观测.实验时,分别使用主动型地面氢钟和被动型星载氢钟作为频率基准,利用上海天文台佘山25m射电望远镜和其他测站对我国火星探测器天问一号进行了交替VLBI观测.数据处理分析结果表明,基于地面氢钟与星载氢钟的VLBI残余群时延标准差均在0.5ns以内,表明星载氢钟可满足深空探测VLBI测定轨的精度要求,验证了其作为月球VLBI测站频率基准的可行性.