The finite volume method has been successfully applied in several engineering fields and has shown outstanding performance in fluid dynamics simulation. In this paper, the general framework for the simulation ofnear-w...The finite volume method has been successfully applied in several engineering fields and has shown outstanding performance in fluid dynamics simulation. In this paper, the general framework for the simulation ofnear-wellbore systems using the finite volume method is described. The mathematical model and the numerical model developed by the authors are presented and discussed. A radial geometry in the vertical plane was implemented so as to thoroughly describe near-wellbore phenomena. The model was then used to simulate injection tests in an oil reservoir through a horizontal well and proved very powerful to correctly reproduce the transient pressure behavior. The reason for this is the robustness of the method, which is independent of the gridding options because the discretization is performed in the physical space. The model is able to describe the phenomena taking place in the reservoir even in complex situations, i.e. in the presence of heterogeneities and permeability barriers, demonstrating the flexibility of the finite volume method when simulating non-conventional tests. The results are presented in comparison with those obtained with the finite difference numerical approach and with analytical methods, if possible.展开更多
We present numerical simulations of blood flow through a brain vascular aneurysm with an artificial stent using Smoothed Particle Hydrodynamics (SPH). The aim of this work is to analyze how the flow into an aneurysm c...We present numerical simulations of blood flow through a brain vascular aneurysm with an artificial stent using Smoothed Particle Hydrodynamics (SPH). The aim of this work is to analyze how the flow into an aneurysm changes using different stent configurations. The initial conditions for the simulations were constructed from angiographic images of a real patient with an aneurysm. The wall shear stresses, pressure and highest velocity within the artery, and other particular quantities are calculated which are of medical specific interest. The numerical simulations of the cerebral circulation help doctors to determine if the patient’s own vascular anatomy has the conditions to allow arterial stenting by endovascular method before the surgery or even evaluate the effect of different stent structure and materials. The results show that the flow downstream the aneurysm is highly modified by the stent configuration and that the best choice for reducing the flow in the aneurysm is to use a completely extended Endeavor stent.展开更多
文摘The finite volume method has been successfully applied in several engineering fields and has shown outstanding performance in fluid dynamics simulation. In this paper, the general framework for the simulation ofnear-wellbore systems using the finite volume method is described. The mathematical model and the numerical model developed by the authors are presented and discussed. A radial geometry in the vertical plane was implemented so as to thoroughly describe near-wellbore phenomena. The model was then used to simulate injection tests in an oil reservoir through a horizontal well and proved very powerful to correctly reproduce the transient pressure behavior. The reason for this is the robustness of the method, which is independent of the gridding options because the discretization is performed in the physical space. The model is able to describe the phenomena taking place in the reservoir even in complex situations, i.e. in the presence of heterogeneities and permeability barriers, demonstrating the flexibility of the finite volume method when simulating non-conventional tests. The results are presented in comparison with those obtained with the finite difference numerical approach and with analytical methods, if possible.
文摘We present numerical simulations of blood flow through a brain vascular aneurysm with an artificial stent using Smoothed Particle Hydrodynamics (SPH). The aim of this work is to analyze how the flow into an aneurysm changes using different stent configurations. The initial conditions for the simulations were constructed from angiographic images of a real patient with an aneurysm. The wall shear stresses, pressure and highest velocity within the artery, and other particular quantities are calculated which are of medical specific interest. The numerical simulations of the cerebral circulation help doctors to determine if the patient’s own vascular anatomy has the conditions to allow arterial stenting by endovascular method before the surgery or even evaluate the effect of different stent structure and materials. The results show that the flow downstream the aneurysm is highly modified by the stent configuration and that the best choice for reducing the flow in the aneurysm is to use a completely extended Endeavor stent.