Three- and four-bucket offshore wind power foundations with a new form of force-transferring structure are proposed in this paper, and the integrated finite element model of foundation-soil-transition structure is est...Three- and four-bucket offshore wind power foundations with a new form of force-transferring structure are proposed in this paper, and the integrated finite element model of foundation-soil-transition structure is established by using ABAQUS. The carrying capacity of the proposed foundations is studied under vertical load, horizontal load and bending moment. It can be seen that the vertical bearing capacity of multi-bucket foundation can be roughly estimated by the vertical bearing capacity of single-bucket; the horizontal bearing capacity of the three-bucket foundation scheme is controlled by displacement, while that of the four-bucket foundation scheme is controlled by the internal forces of soils. Moreover, the carrying capacity is provided by the overall structure formed by multi-bucket before soil failure. Compared with the conventional single-bucket foundation, there are mainly tension and pressure that are applied to the multi-bucket foundation, so that the carrying capacity of the foundation can be fully utilized. The probability of soil failure can be well reduced with the proposed multi-bucket foundation, and the stress transmission of force-transferring structure is more consistent through steel beams with variable cross-section.展开更多
The bucket foundation is a new type of foundation for offshore application to intermediate-depth waters. It has advantages over conventional ones. However, there is no consensus in the analysis and design of this type...The bucket foundation is a new type of foundation for offshore application to intermediate-depth waters. It has advantages over conventional ones. However, there is no consensus in the analysis and design of this type of foundation. In this paper, the lateral bearing capacity and the failure mechanism of multi-bucket foundations are studied with different connection stiffness and bucket spacing by use of a three-dimensional finite element method. Based on the numerical analysis results, a limit analysis method of plasticity for evaluating the lateral bearing capacity of large-spacing multi- bucket foundation with rigid connection in soft ground is proposed. This method provides a simple procedure that gives results comparable to those from the finite element analyses.展开更多
Suction foundations are generally installed with negative pressures to overcome the resistance of soils and complete the penetration,but excessive negative pressures are also avoided to cause seepage damages.In this p...Suction foundations are generally installed with negative pressures to overcome the resistance of soils and complete the penetration,but excessive negative pressures are also avoided to cause seepage damages.In this paper,the model test method was used to analyze the movement characteristics of multi-bucket foundations in the process of sinking in sand,and the common calculation methods of sinking resistances are verified.The critical negative pressure corresponding to the seepage failure of foundation was determined under the action of increasing negative pressure step by step and the characteristics of soil failure were studied.The calculation formula of critical suction in sand was verified in application,and according to the test results,the value of seepage coefficient was modified,which provides an example for the study of suction foundation in sand soils.展开更多
基金Supported by the National Natural Science Foundation of China(No.51309179)the Tianjin Municipal Natural Science Foundation(No.14JCQNJC07000)
文摘Three- and four-bucket offshore wind power foundations with a new form of force-transferring structure are proposed in this paper, and the integrated finite element model of foundation-soil-transition structure is established by using ABAQUS. The carrying capacity of the proposed foundations is studied under vertical load, horizontal load and bending moment. It can be seen that the vertical bearing capacity of multi-bucket foundation can be roughly estimated by the vertical bearing capacity of single-bucket; the horizontal bearing capacity of the three-bucket foundation scheme is controlled by displacement, while that of the four-bucket foundation scheme is controlled by the internal forces of soils. Moreover, the carrying capacity is provided by the overall structure formed by multi-bucket before soil failure. Compared with the conventional single-bucket foundation, there are mainly tension and pressure that are applied to the multi-bucket foundation, so that the carrying capacity of the foundation can be fully utilized. The probability of soil failure can be well reduced with the proposed multi-bucket foundation, and the stress transmission of force-transferring structure is more consistent through steel beams with variable cross-section.
基金supported by the National Natural Science Foundation of China(Grant No.50639010)the Doctoral Special Branch Foundation by the Ministry of Education of China(Grant No.20060141017)
文摘The bucket foundation is a new type of foundation for offshore application to intermediate-depth waters. It has advantages over conventional ones. However, there is no consensus in the analysis and design of this type of foundation. In this paper, the lateral bearing capacity and the failure mechanism of multi-bucket foundations are studied with different connection stiffness and bucket spacing by use of a three-dimensional finite element method. Based on the numerical analysis results, a limit analysis method of plasticity for evaluating the lateral bearing capacity of large-spacing multi- bucket foundation with rigid connection in soft ground is proposed. This method provides a simple procedure that gives results comparable to those from the finite element analyses.
基金The authors would like to acknowledge the support from the National Natural Science Foundation of China(No.52171274).
文摘Suction foundations are generally installed with negative pressures to overcome the resistance of soils and complete the penetration,but excessive negative pressures are also avoided to cause seepage damages.In this paper,the model test method was used to analyze the movement characteristics of multi-bucket foundations in the process of sinking in sand,and the common calculation methods of sinking resistances are verified.The critical negative pressure corresponding to the seepage failure of foundation was determined under the action of increasing negative pressure step by step and the characteristics of soil failure were studied.The calculation formula of critical suction in sand was verified in application,and according to the test results,the value of seepage coefficient was modified,which provides an example for the study of suction foundation in sand soils.