An upwind finite element(FE)based algorithm to calculate the ion flow field in the vicinity of multi-circuit DC transmission lines is described.The initial value estimation and boundary condition are optimized,so deta...An upwind finite element(FE)based algorithm to calculate the ion flow field in the vicinity of multi-circuit DC transmission lines is described.The initial value estimation and boundary condition are optimized,so details of the transmission lines such as bundle conductors and ground wires can be taken into account in the simulation model.Comparison between measured and computed ground level total electrical field and ion current density shows satisfactory agreement.The ion flow field of a ±500 kV HVDC project with bipolar lines on the same tower is simulated.The total electrical field and ion current density on ground level are compared among different line arrangements.展开更多
The DC fault characteristics of voltage source converter based high voltage direct current(VSC-HVDC)systems are analyzed in this paper.The phenomenon whereby the capacitor on DC side discharges quickly during a DC fau...The DC fault characteristics of voltage source converter based high voltage direct current(VSC-HVDC)systems are analyzed in this paper.The phenomenon whereby the capacitor on DC side discharges quickly during a DC fault contributes to a large short-circuit fault current.Neither traditional DC breakers nor DC switches can cut off the fault current under this condition.A fast solid state DC breaker design method is proposed in this paper.This method is based on the fault current characteristics of the inverter in multi-terminal HVDC systems(MTDC),where a fault current appears at the natural zerocrossing point near the inverter.At this point,by coordinating the AC breakers near the rectifier,the DC breaker could reliably cut off the DC fault current and protect the system.A detailed model for this fast solid state DC breaker and its operation sequence are studied,based on this design method.Simulations modeling a five-terminal meshed DC grid and a fast DC breaker were carried out with PSCAD/EMTDC using this design method.The results from the simulations confirmed the validity of the design method.展开更多
For a multi-inverter grid-connected system,the stability of the point of common coupling(PCC)voltage is evaluated considering the distribution parameters of the transmission lines.First,the systems on both sides of th...For a multi-inverter grid-connected system,the stability of the point of common coupling(PCC)voltage is evaluated considering the distribution parameters of the transmission lines.First,the systems on both sides of the PCC are equalized,a smallsignal equivalent circuit similar to the“current source-grid”is established,and a mathematical model for the voltage of the PCC is derived.Then,using Euler’s formula and Nyquist stability criterion,the PCC voltage stability of the grid-connected system is evaluated by the impedance analysis method under the premise that the single-side excitation is stable.In addition,the gridconnected conditions causing PCC voltage instability are studied.A phase compensation method based on an impedance phase compensation control strategy is introduced.The stability of the grid-connected system is improved by compensating the phase margin at the equivalent impedance crossover-section frequency on both sides of the grid-connected system PCC.Finally,a simulation circuit is built to simulate and analyze the proposed model and phase compensation method.The simulation results verify the accuracy and effectiveness of the theoretical analysis.展开更多
220 k V线路是当前省网主干网架,雷击跳闸是220 k V线路跳闸的主要原因。以四川电网220 k V同塔双回沫竹一二线雷电反击四相同跳故障为分析对象,基于电磁暂态软件ATP-EMTP,对同塔双回线路反击多相同跳机理及特性进行研究。研究表明:在...220 k V线路是当前省网主干网架,雷击跳闸是220 k V线路跳闸的主要原因。以四川电网220 k V同塔双回沫竹一二线雷电反击四相同跳故障为分析对象,基于电磁暂态软件ATP-EMTP,对同塔双回线路反击多相同跳机理及特性进行研究。研究表明:在一定的杆塔结构下,杆塔接地电阻和雷击时刻导线电压初始值对多相反击耐雷水平影响显著;在接地电阻较低时,应采用非平衡绝缘加强上相绝缘水平,接地电阻较大时,应采用各相平衡绝缘;多相绝缘子两端电压相近的时刻发生雷击同跳几率较大。展开更多
Cold-junction compensation(CJC)and disconnection detection circuit design of various thermocouples(TC)and multi-channel TC interface circuits were designed.The CJC and disconnection detection circuit consists of a CJC...Cold-junction compensation(CJC)and disconnection detection circuit design of various thermocouples(TC)and multi-channel TC interface circuits were designed.The CJC and disconnection detection circuit consists of a CJC semiconductor device,an instrumentation amplifier(IA),two resistors,and a diode for disconnection detection.Based on the basic circuit,a multi-channel interface circuit was also implemented.The CJC was implemented using compensation semiconductor and IA,and disconnection detection was detected by using two resistors and a diode so that IA input voltage became-0.42 V.As a result of the experiment using R-type TC,the error of the designed circuit was reduced from 0.14 mV to 3μV after CJC in the temperature range of 0°C to 1400°C.In addition,it was confirmed that the output voltage of IA was saturated from 88 mV to-14.2 V when TC was disconnected from normal.The output voltage of the designed circuit was 0 V to 10 V in the temperature range of 0°C to 1400°C.The results of the 4-channel interface experiment using R-type TC were almost identical to the CJC and disconnection detection results for each channel.The implemented multi-channel interface has a feature that can be applied equally to E,J,K,T,R,and S-type TCs by changing the terminals of CJC semiconductor devices and adjusting the IA gain.展开更多
基金Project Supported by China11th Five-year National Key Technologies R&D Program(2006BAA02A20)
文摘An upwind finite element(FE)based algorithm to calculate the ion flow field in the vicinity of multi-circuit DC transmission lines is described.The initial value estimation and boundary condition are optimized,so details of the transmission lines such as bundle conductors and ground wires can be taken into account in the simulation model.Comparison between measured and computed ground level total electrical field and ion current density shows satisfactory agreement.The ion flow field of a ±500 kV HVDC project with bipolar lines on the same tower is simulated.The total electrical field and ion current density on ground level are compared among different line arrangements.
基金This work is supported by National Natural Science Foundation of China under the contract 51261130484by State Grid Corporation of China under the contract State Grid Research 304(2013).
文摘The DC fault characteristics of voltage source converter based high voltage direct current(VSC-HVDC)systems are analyzed in this paper.The phenomenon whereby the capacitor on DC side discharges quickly during a DC fault contributes to a large short-circuit fault current.Neither traditional DC breakers nor DC switches can cut off the fault current under this condition.A fast solid state DC breaker design method is proposed in this paper.This method is based on the fault current characteristics of the inverter in multi-terminal HVDC systems(MTDC),where a fault current appears at the natural zerocrossing point near the inverter.At this point,by coordinating the AC breakers near the rectifier,the DC breaker could reliably cut off the DC fault current and protect the system.A detailed model for this fast solid state DC breaker and its operation sequence are studied,based on this design method.Simulations modeling a five-terminal meshed DC grid and a fast DC breaker were carried out with PSCAD/EMTDC using this design method.The results from the simulations confirmed the validity of the design method.
文摘For a multi-inverter grid-connected system,the stability of the point of common coupling(PCC)voltage is evaluated considering the distribution parameters of the transmission lines.First,the systems on both sides of the PCC are equalized,a smallsignal equivalent circuit similar to the“current source-grid”is established,and a mathematical model for the voltage of the PCC is derived.Then,using Euler’s formula and Nyquist stability criterion,the PCC voltage stability of the grid-connected system is evaluated by the impedance analysis method under the premise that the single-side excitation is stable.In addition,the gridconnected conditions causing PCC voltage instability are studied.A phase compensation method based on an impedance phase compensation control strategy is introduced.The stability of the grid-connected system is improved by compensating the phase margin at the equivalent impedance crossover-section frequency on both sides of the grid-connected system PCC.Finally,a simulation circuit is built to simulate and analyze the proposed model and phase compensation method.The simulation results verify the accuracy and effectiveness of the theoretical analysis.
文摘220 k V线路是当前省网主干网架,雷击跳闸是220 k V线路跳闸的主要原因。以四川电网220 k V同塔双回沫竹一二线雷电反击四相同跳故障为分析对象,基于电磁暂态软件ATP-EMTP,对同塔双回线路反击多相同跳机理及特性进行研究。研究表明:在一定的杆塔结构下,杆塔接地电阻和雷击时刻导线电压初始值对多相反击耐雷水平影响显著;在接地电阻较低时,应采用非平衡绝缘加强上相绝缘水平,接地电阻较大时,应采用各相平衡绝缘;多相绝缘子两端电压相近的时刻发生雷击同跳几率较大。
文摘Cold-junction compensation(CJC)and disconnection detection circuit design of various thermocouples(TC)and multi-channel TC interface circuits were designed.The CJC and disconnection detection circuit consists of a CJC semiconductor device,an instrumentation amplifier(IA),two resistors,and a diode for disconnection detection.Based on the basic circuit,a multi-channel interface circuit was also implemented.The CJC was implemented using compensation semiconductor and IA,and disconnection detection was detected by using two resistors and a diode so that IA input voltage became-0.42 V.As a result of the experiment using R-type TC,the error of the designed circuit was reduced from 0.14 mV to 3μV after CJC in the temperature range of 0°C to 1400°C.In addition,it was confirmed that the output voltage of IA was saturated from 88 mV to-14.2 V when TC was disconnected from normal.The output voltage of the designed circuit was 0 V to 10 V in the temperature range of 0°C to 1400°C.The results of the 4-channel interface experiment using R-type TC were almost identical to the CJC and disconnection detection results for each channel.The implemented multi-channel interface has a feature that can be applied equally to E,J,K,T,R,and S-type TCs by changing the terminals of CJC semiconductor devices and adjusting the IA gain.