This paper introduces a novel fiat plate solar collector (FPC) using micro heat pipe array (MHPA) as a key element. To analyze the thermal transfer behavior of flat plate solar collector with micro heat pipe array...This paper introduces a novel fiat plate solar collector (FPC) using micro heat pipe array (MHPA) as a key element. To analyze the thermal transfer behavior of flat plate solar collector with micro heat pipe array (MHPA-FPC), an indoor experiment for thermal transfer characteristic of MHPA applied to FPC was conducted by using an electrical heating film to simulate the solar radiation. Different cooling water flow rates, cooling water temperatures, slopes, and contact thermal resistances be- tween the condenser of MHPA and the heat exchanger were tested at different heating powers. The experimental results in- dicate that MHPA-FPC exhibits the enhanced heat transfer capability with increased cooling water flow rate and temperature. Total thermal resistance has a maximum decline of approximately 10% when the flow rate increases from 180 to 360 L h-1 and 38% when the cooling water temperature increases from 20~C to 40~C. When the inclination angle of MHPA-FPC ex- ceeds 30~, the slope change has a negligible effect on the heat transfer performance of MHPA-FPC. In addition, contact thermal resistance significantly affects the heat transfer capability of MHPA-FPC. The total thermal resistances lowers to nearly half of the original level when contact material between the condenser of MHPA and the heat exchanger changes from conductive silicone to conductive grease. These results could provide useful information for the optimal design and operation of MHPA-FPC.展开更多
温度是影响动力电池性能的关键因素.高效热管理技术可有效控制动力电池温度和温差.本研究采用微通道热管阵列作为电池热管理系统的热传导元件,分析了其在高热功率密度下的传热性能,理论计算了其等效导热系数,优化分析了其槽道尺寸对流...温度是影响动力电池性能的关键因素.高效热管理技术可有效控制动力电池温度和温差.本研究采用微通道热管阵列作为电池热管理系统的热传导元件,分析了其在高热功率密度下的传热性能,理论计算了其等效导热系数,优化分析了其槽道尺寸对流动传热的影响,对比了其与主流散热技术的性能差异.研究发现,热功率密度为0.3658 W cm^-2时,强制风冷散热条件下,采用微通道热管阵列技术可维持热源处表面温度45℃以下,温差1.3℃以下,低于无微通道热管阵列导热情况下的温升15℃,温差3.8℃.随着热功率密度增大至0.9176 W cm^-2,微通道热管阵列的等效导热系数增大为6027 W m^-1K^-1,其热源处表面最大瞬态温差约2.75℃.增大槽道尺寸参数可进一步改善微通道热管阵列的导热系数,改善其传热性能,但对液体回流驱动力有一定影响.该阵列具有较好的动态工况热稳定性和低温快速加热能力.与烧结热管组的温度性能相比,微通道热管阵列组最大温度可降低15.1℃,表面温差降低14℃,具有显著降温和均温优势,表明微通道热管阵列在动力电池热管理系统中具有广泛应用前景.展开更多
A novel micro heat pipe array was used in solar panel cooling. Both of air-cooling and water-cooling conditions under nature convection condition were investigated in this paper. Compared with the ordinary solar panel...A novel micro heat pipe array was used in solar panel cooling. Both of air-cooling and water-cooling conditions under nature convection condition were investigated in this paper. Compared with the ordinary solar panel, the maximum difference of the photoelectric conversion efficiency is 2.6%, the temperature reduces maximally by 4.7℃, the output power increases maximally by 8.4% for the solar panel with heat pipe using air-cooling, when the daily radiation value is 26.3 MJ. Compared with the solar panel with heat pipe using air-cooling, the maximum difference of the photoelectric conversion efficiency is 3%, the temperature reduces maximally by 8℃, the output power increases maximally by 13.9% for the solar panel with heat pipe using water-cooling, when the daily radiation value is 21.9 MJ.展开更多
This paper proposes two new radiant floor heating structures based on micro heat pipe array(MHPA),namely cement-tile floor and keel-wood floor.The numerical models for these different floor structures are established ...This paper proposes two new radiant floor heating structures based on micro heat pipe array(MHPA),namely cement-tile floor and keel-wood floor.The numerical models for these different floor structures are established and verified by experiments.The temperature distribution and heat transfer process of each part are comprehensively obtained,and the structure is optimized.The results show that the cement-tile floor has the better heat transfer performance of the two.When under the same inlet water temperature and flow rate,the keel-wood floor's surface temperature distribution is about 2℃ lower than that of the cement-tile floor.The inlet water temperature of cement-tile floor is about 10℃ lower than that of keel-wood structure when the floor surface temperature is the same.During a longitudinal heat transfer above MHPA,the floor surface temperature decreases by 0.5℃ for every 10 mm filling layer increase.In order to reduce the non-uniformity of the floor's surface temperature and improve the thermal comfort of the heated room,the optimal structure for a floor is given,with the maximum surface temperature difference reduced by 3.35℃.We used research focusing on new radiant floor heating,with advantages including high efficiency heat transfer,low water supply temperature,simple waterway structure,low resistance and leakage risk,to provide theory and data to support the application of an effective radiant floor heating based on MHPA.展开更多
基金financially supported by the Natural Science Foundation of Beijing(Grant No.Z1004020201201)the Opening Funds of State Key Laboratory of Building Safety and Build Environment of China(Grant No.BSBE 2011-07)
文摘This paper introduces a novel fiat plate solar collector (FPC) using micro heat pipe array (MHPA) as a key element. To analyze the thermal transfer behavior of flat plate solar collector with micro heat pipe array (MHPA-FPC), an indoor experiment for thermal transfer characteristic of MHPA applied to FPC was conducted by using an electrical heating film to simulate the solar radiation. Different cooling water flow rates, cooling water temperatures, slopes, and contact thermal resistances be- tween the condenser of MHPA and the heat exchanger were tested at different heating powers. The experimental results in- dicate that MHPA-FPC exhibits the enhanced heat transfer capability with increased cooling water flow rate and temperature. Total thermal resistance has a maximum decline of approximately 10% when the flow rate increases from 180 to 360 L h-1 and 38% when the cooling water temperature increases from 20~C to 40~C. When the inclination angle of MHPA-FPC ex- ceeds 30~, the slope change has a negligible effect on the heat transfer performance of MHPA-FPC. In addition, contact thermal resistance significantly affects the heat transfer capability of MHPA-FPC. The total thermal resistances lowers to nearly half of the original level when contact material between the condenser of MHPA and the heat exchanger changes from conductive silicone to conductive grease. These results could provide useful information for the optimal design and operation of MHPA-FPC.
文摘温度是影响动力电池性能的关键因素.高效热管理技术可有效控制动力电池温度和温差.本研究采用微通道热管阵列作为电池热管理系统的热传导元件,分析了其在高热功率密度下的传热性能,理论计算了其等效导热系数,优化分析了其槽道尺寸对流动传热的影响,对比了其与主流散热技术的性能差异.研究发现,热功率密度为0.3658 W cm^-2时,强制风冷散热条件下,采用微通道热管阵列技术可维持热源处表面温度45℃以下,温差1.3℃以下,低于无微通道热管阵列导热情况下的温升15℃,温差3.8℃.随着热功率密度增大至0.9176 W cm^-2,微通道热管阵列的等效导热系数增大为6027 W m^-1K^-1,其热源处表面最大瞬态温差约2.75℃.增大槽道尺寸参数可进一步改善微通道热管阵列的导热系数,改善其传热性能,但对液体回流驱动力有一定影响.该阵列具有较好的动态工况热稳定性和低温快速加热能力.与烧结热管组的温度性能相比,微通道热管阵列组最大温度可降低15.1℃,表面温差降低14℃,具有显著降温和均温优势,表明微通道热管阵列在动力电池热管理系统中具有广泛应用前景.
文摘A novel micro heat pipe array was used in solar panel cooling. Both of air-cooling and water-cooling conditions under nature convection condition were investigated in this paper. Compared with the ordinary solar panel, the maximum difference of the photoelectric conversion efficiency is 2.6%, the temperature reduces maximally by 4.7℃, the output power increases maximally by 8.4% for the solar panel with heat pipe using air-cooling, when the daily radiation value is 26.3 MJ. Compared with the solar panel with heat pipe using air-cooling, the maximum difference of the photoelectric conversion efficiency is 3%, the temperature reduces maximally by 8℃, the output power increases maximally by 13.9% for the solar panel with heat pipe using water-cooling, when the daily radiation value is 21.9 MJ.
基金The authors gratefully acknowledge the financial support provided by the National Natural Science Foundation of China(No.51778010),“Optimization design method of BIPV/T and solar heat pump coupled energy supply system”.
文摘This paper proposes two new radiant floor heating structures based on micro heat pipe array(MHPA),namely cement-tile floor and keel-wood floor.The numerical models for these different floor structures are established and verified by experiments.The temperature distribution and heat transfer process of each part are comprehensively obtained,and the structure is optimized.The results show that the cement-tile floor has the better heat transfer performance of the two.When under the same inlet water temperature and flow rate,the keel-wood floor's surface temperature distribution is about 2℃ lower than that of the cement-tile floor.The inlet water temperature of cement-tile floor is about 10℃ lower than that of keel-wood structure when the floor surface temperature is the same.During a longitudinal heat transfer above MHPA,the floor surface temperature decreases by 0.5℃ for every 10 mm filling layer increase.In order to reduce the non-uniformity of the floor's surface temperature and improve the thermal comfort of the heated room,the optimal structure for a floor is given,with the maximum surface temperature difference reduced by 3.35℃.We used research focusing on new radiant floor heating,with advantages including high efficiency heat transfer,low water supply temperature,simple waterway structure,low resistance and leakage risk,to provide theory and data to support the application of an effective radiant floor heating based on MHPA.