The adsorption and desorption behavior of Cr(Ⅵ) in membrane capacitive deionization(MCDI) was investigated systematically in the presence of bovine serum albumin(BSA) and KCl with different concentrations, respective...The adsorption and desorption behavior of Cr(Ⅵ) in membrane capacitive deionization(MCDI) was investigated systematically in the presence of bovine serum albumin(BSA) and KCl with different concentrations, respectively. Results revealed that Cr(Ⅵ) absorption was enhanced and the adsorption amount for Cr(Ⅵ) increased from 155.7 to 190.8 mg/g when KCl concentration increased from 100 to 200 mg/L in the adsorption process, which was attributed to the stronger driving force. However, the adsorption amount sharply decreased to 90.2 mg/g when KCl concentration reached up to 1000 mg/L suggesting the negative effect for Cr(Ⅵ) removal that high KCl concentration had. As for the effect of BSA on ion adsorption, the amount for Cr(Ⅵ) significantly declined to 78.3 mg/g and p H was found to be an important factor contributing to this significant reduction. Then, the desorption performance was also conducted and it was obtained that the presence of KCl had negligible effect on Cr(Ⅵ) desorption, while promoted by the addition of BSA. The incomplete desorption was obtained and the residual chromium ions onto the electrode after desorption was detected via energy-dispersive X-ray spectroscopy(EDS). Based on above analysis, the enhanced removal mechanism for Cr(Ⅵ) in MCDI was found to be consisted of ion adsorption onto electrode surface, the redox reaction of Cr(Ⅵ) into Cr(III)and precipitation, which was demonstrated by X-ray photoelectron spectroscopy(XPS) and scanning electron microscope(SEM).展开更多
A blending chelate filter membrane with high chelate capacity for Ag + has been prepared by blending of phosphoramidic acid resin and polysulfone. The major parameters influencing structure of the chelate filter membr...A blending chelate filter membrane with high chelate capacity for Ag + has been prepared by blending of phosphoramidic acid resin and polysulfone. The major parameters influencing structure of the chelate filter membranes such as the blending ratio, phosphoramidic acid resin grain size and temperature of casting solution have been studied. The relationship among the chelate amount of Ag +, pH value, Ag + concentration and phosphoramidic acid resin grain diameter were examined. The chelate filter membrane had a capacity of 1 438 μg/cm 2 for Ag + under appropriate conditions. Sorption isotherm of Ag + could be expressed with the Freundlich sorption model. The dynamic chelate experiments proved that the sorption and desorption of membranes could be realized simultaneously for Ag +.展开更多
Membrane gas-solvent contactors are a hybrid technology combining solvent absorption with membrane gas separation, which demonstrates potential for CO_2 capture through the ability of the membrane to rigidly control t...Membrane gas-solvent contactors are a hybrid technology combining solvent absorption with membrane gas separation, which demonstrates potential for CO_2 capture through the ability of the membrane to rigidly control the mass transfer area. Membrane contactors have been successfully demonstrated for CO_2 absorption, and there is strong research interest in using membrane contactors for the complimentary CO_2 desorption process to regenerate the solvent. However, understanding and modelling the various stages of mass transfer in the desorption process is less well-known, given the existing mass transfer correlations had been developed from absorption experiments. Hence, mass transfer correlations for membrane contactors are reviewed here, and their appropriateness for desorption analysed. This is achieved through simulating CO_2 desorption through a membrane contactor from loaded 30 wt% monoethanolamine solvent to enable comparison of the correlations. It was found that the most cited correlations by Yang and Cussler were valid for shell side parallel flow, while that of Kreith and Black was viable for shell side cross flow. A limitation of all of these correlations is that they assume single phase flow on both sides of the membrane; however, the high temperature of CO_2 desorption can lead to partial solvent vaporisation and hence two phases present on one side of the membrane contactor during desorption. A mass transfer correlation is established here for two phase parallel flow on the shell side of a membrane contactor, based on experimental results for three composite and one asymmetric hollow fibre membrane contactors stripping CO_2 from loaded MEA at 105–108 °C. This correlation is comparable to that reported in the literature for mass transfer in other two phase systems, but differs from the standard format for membrane contactors in terms of the exponent on the dimensionless Schmidt and Reynolds numbers.展开更多
基金financially supported by the National Natural Science Fund of China (No. 51508153)the Natural Science Fund of Jiangsu (No. BK20150813)+1 种基金the Fundamental Research Funds for the Central UniversitiesA Project Funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions
文摘The adsorption and desorption behavior of Cr(Ⅵ) in membrane capacitive deionization(MCDI) was investigated systematically in the presence of bovine serum albumin(BSA) and KCl with different concentrations, respectively. Results revealed that Cr(Ⅵ) absorption was enhanced and the adsorption amount for Cr(Ⅵ) increased from 155.7 to 190.8 mg/g when KCl concentration increased from 100 to 200 mg/L in the adsorption process, which was attributed to the stronger driving force. However, the adsorption amount sharply decreased to 90.2 mg/g when KCl concentration reached up to 1000 mg/L suggesting the negative effect for Cr(Ⅵ) removal that high KCl concentration had. As for the effect of BSA on ion adsorption, the amount for Cr(Ⅵ) significantly declined to 78.3 mg/g and p H was found to be an important factor contributing to this significant reduction. Then, the desorption performance was also conducted and it was obtained that the presence of KCl had negligible effect on Cr(Ⅵ) desorption, while promoted by the addition of BSA. The incomplete desorption was obtained and the residual chromium ions onto the electrode after desorption was detected via energy-dispersive X-ray spectroscopy(EDS). Based on above analysis, the enhanced removal mechanism for Cr(Ⅵ) in MCDI was found to be consisted of ion adsorption onto electrode surface, the redox reaction of Cr(Ⅵ) into Cr(III)and precipitation, which was demonstrated by X-ray photoelectron spectroscopy(XPS) and scanning electron microscope(SEM).
文摘A blending chelate filter membrane with high chelate capacity for Ag + has been prepared by blending of phosphoramidic acid resin and polysulfone. The major parameters influencing structure of the chelate filter membranes such as the blending ratio, phosphoramidic acid resin grain size and temperature of casting solution have been studied. The relationship among the chelate amount of Ag +, pH value, Ag + concentration and phosphoramidic acid resin grain diameter were examined. The chelate filter membrane had a capacity of 1 438 μg/cm 2 for Ag + under appropriate conditions. Sorption isotherm of Ag + could be expressed with the Freundlich sorption model. The dynamic chelate experiments proved that the sorption and desorption of membranes could be realized simultaneously for Ag +.
文摘Membrane gas-solvent contactors are a hybrid technology combining solvent absorption with membrane gas separation, which demonstrates potential for CO_2 capture through the ability of the membrane to rigidly control the mass transfer area. Membrane contactors have been successfully demonstrated for CO_2 absorption, and there is strong research interest in using membrane contactors for the complimentary CO_2 desorption process to regenerate the solvent. However, understanding and modelling the various stages of mass transfer in the desorption process is less well-known, given the existing mass transfer correlations had been developed from absorption experiments. Hence, mass transfer correlations for membrane contactors are reviewed here, and their appropriateness for desorption analysed. This is achieved through simulating CO_2 desorption through a membrane contactor from loaded 30 wt% monoethanolamine solvent to enable comparison of the correlations. It was found that the most cited correlations by Yang and Cussler were valid for shell side parallel flow, while that of Kreith and Black was viable for shell side cross flow. A limitation of all of these correlations is that they assume single phase flow on both sides of the membrane; however, the high temperature of CO_2 desorption can lead to partial solvent vaporisation and hence two phases present on one side of the membrane contactor during desorption. A mass transfer correlation is established here for two phase parallel flow on the shell side of a membrane contactor, based on experimental results for three composite and one asymmetric hollow fibre membrane contactors stripping CO_2 from loaded MEA at 105–108 °C. This correlation is comparable to that reported in the literature for mass transfer in other two phase systems, but differs from the standard format for membrane contactors in terms of the exponent on the dimensionless Schmidt and Reynolds numbers.