Background So far, in China, there has been no effective or easy procedure to define the control of asthma. This study assesses the validity of Asthma Control Test in Chinese patients. Methods Three questionnaires (A...Background So far, in China, there has been no effective or easy procedure to define the control of asthma. This study assesses the validity of Asthma Control Test in Chinese patients. Methods Three questionnaires (Asthma Control Test, Asthma Control Questionnaire and the 30 second asthma test) were administered to 305 asthma patients from 10 teaching hospitals across China. Spirometry was also used. Asthma specialists rated the control of asthma according to patients' symptoms, medications and forced expiratory volume in first second. The patients were divided into noncontrolled group and controlled group according to the specialists' rating. Reliability, empirical validity and screening accuracy were conducted for Asthma Control Test scores. Screening accuracy was compared among 3 questionnaires. The patients' self rating and the specialists' rating were also compared. Results The internal consistency reliability of the 5-item Asthma Control Test was 0.854. The correlation coefficient between Asthma Control Test and the specialists' rating was 0.729, which was higher than other instruments. Asthma Control Test scores discriminated between groups of patients differing in the percent predicted forced expiratory volume in first second (F=-26.06, P〈0.0001), the specialists' rating of asthma control (F=-88.24, P〈0.0001) and the Asthma Control Questionnaire scores (F=-250.57, P〈0.0001). Asthma Control Test showed no significant difference with Asthma Control Questionnaire in the percent correctly classified, while the percent correctly classified by Asthma Control Test was much higher than 30 second asthma test. The patients' self rating was the same as assessment of the specialists (t=0.65, P=-0.516). Conclusion The Asthma Control Test is an effective and practicable method for assessing asthma control in China.展开更多
患者报告结局测量工具(patient-reported outcome measures,PROMs)测量属性研究是指研究者为效验PROMs的测量属性(如信度)而进行的一系列研究。如果在这些测量属性研究的设计和统计分析过程中存在缺陷,就会产生偏倚,影响测量工具的质量...患者报告结局测量工具(patient-reported outcome measures,PROMs)测量属性研究是指研究者为效验PROMs的测量属性(如信度)而进行的一系列研究。如果在这些测量属性研究的设计和统计分析过程中存在缺陷,就会产生偏倚,影响测量工具的质量。COSMIN(consensus-based standards for the selection of health measurement instruments)指导委员会开发了COSMIN-RoB清单用以评估测量属性研究的偏倚风险,该清单可用于制作PROMs测量属性的系统评价,同时对于PROMs开发者而言,也可使用该清单指导测量工具的开发。目前,在国内尚缺乏测量属性研究的偏倚风险评估工具,因此本文旨在介绍COSMIN-RoB清单的基本情况和使用原则,同时结合实例对内部结构研究部分的评价清单进行解读,以期指导研究者使用COSMIN-RoB清单。展开更多
文摘Background So far, in China, there has been no effective or easy procedure to define the control of asthma. This study assesses the validity of Asthma Control Test in Chinese patients. Methods Three questionnaires (Asthma Control Test, Asthma Control Questionnaire and the 30 second asthma test) were administered to 305 asthma patients from 10 teaching hospitals across China. Spirometry was also used. Asthma specialists rated the control of asthma according to patients' symptoms, medications and forced expiratory volume in first second. The patients were divided into noncontrolled group and controlled group according to the specialists' rating. Reliability, empirical validity and screening accuracy were conducted for Asthma Control Test scores. Screening accuracy was compared among 3 questionnaires. The patients' self rating and the specialists' rating were also compared. Results The internal consistency reliability of the 5-item Asthma Control Test was 0.854. The correlation coefficient between Asthma Control Test and the specialists' rating was 0.729, which was higher than other instruments. Asthma Control Test scores discriminated between groups of patients differing in the percent predicted forced expiratory volume in first second (F=-26.06, P〈0.0001), the specialists' rating of asthma control (F=-88.24, P〈0.0001) and the Asthma Control Questionnaire scores (F=-250.57, P〈0.0001). Asthma Control Test showed no significant difference with Asthma Control Questionnaire in the percent correctly classified, while the percent correctly classified by Asthma Control Test was much higher than 30 second asthma test. The patients' self rating was the same as assessment of the specialists (t=0.65, P=-0.516). Conclusion The Asthma Control Test is an effective and practicable method for assessing asthma control in China.
文摘患者报告结局测量工具(patient-reported outcome measures,PROMs)测量属性研究是指研究者为效验PROMs的测量属性(如信度)而进行的一系列研究。如果在这些测量属性研究的设计和统计分析过程中存在缺陷,就会产生偏倚,影响测量工具的质量。COSMIN(consensus-based standards for the selection of health measurement instruments)指导委员会开发了COSMIN-RoB清单用以评估测量属性研究的偏倚风险,该清单可用于制作PROMs测量属性的系统评价,同时对于PROMs开发者而言,也可使用该清单指导测量工具的开发。目前,在国内尚缺乏测量属性研究的偏倚风险评估工具,因此本文旨在介绍COSMIN-RoB清单的基本情况和使用原则,同时结合实例对内部结构研究部分的评价清单进行解读,以期指导研究者使用COSMIN-RoB清单。