Atomic magnetometers operated in the spin-exchange relaxation-free(SERF)regime are the promising sensor to replace superconducting quantum interference devices(SQUIDs)in the biomagnetism field.The SERF magnetometer wi...Atomic magnetometers operated in the spin-exchange relaxation-free(SERF)regime are the promising sensor to replace superconducting quantum interference devices(SQUIDs)in the biomagnetism field.The SERF magnetometer with compact size and good performance is crucial to the new generation of wearable magnetoencephalography(MEG)system.In this paper,we developed a compact and closed-loop SERF magnetometer with the dimensions of 15.0×22.0×30.0 mm^(3)based on a single-beam configuration.The bandwidth of the magnetometer was extended to 675 Hz while the sensitivity was maintained at 22 f T/Hz^(1/2).A nearly 3-fold enhancement of the bandwidth was obtained in comparison with the open-loop control.The implementation of the closed-loop control also greatly improved the dynamic range,enabling the magnetometer to be robust against the disturbance of the ambient field.Moreover,the magnetometer was successfully applied for the detection of humanα-rhythm and auditory evoked fields(AEFs),which demonstrated the potential to be extended to multi-channel MEG measurements for future neuroscience studies.展开更多
Previous studies examining coherence and connectivity deviations in schizophrenia patients relied on standard coherence measures between recording sites (at the sensor level). A coherence source imaging (CSI) methodol...Previous studies examining coherence and connectivity deviations in schizophrenia patients relied on standard coherence measures between recording sites (at the sensor level). A coherence source imaging (CSI) methodology where coherence is assessed within imaged brain structures (at the source level) was developed recently by our group and applied successfully for detecting coherent areas in the cortical networks of patients with epilepsy. We applied this Magnetoencephalography (MEG)-CSI technique to measure normal and pathological patterns of brain oscillations (biomarkers) in normal subjects and patients diagnosed with schizophrenia. Twelve patients diagnosed with schizophrenia and twelve healthy control subjects were studied. A ten-minute resting state MEG brain scan was performed with eyes open. MEG-CSI analysis was performed to identify the cortical areas that interacted strongly within the 3 - 50 Hz frequency range. Statistically significant increased regions of coherence were detected in schizophrenia patients compared to controls in the right inferior frontal gyrus (BA 47—pars orbitalis), left superior frontal gyrus (BA9— dorsolateral prefrontal cortex), right middle frontal gyrus (BA 10—anterior prefrontal cortex & BA 46—dorsolateral prefrontal cortex), and right cingulate gyrus (BA 24—ventral anterior cingulate cortex). These areas are involved in language, memory, decision making, empathy, executive and, higher cognitive functioning. We conclude that MEG-CSI can detect imaging biomarkers from resting state brain activity in schizophrenia patients that deviates from normal control subjects in several behaviorally salient brain regions. Analysis with MEG-CSI can provide biomarkers of abnormalities in the resting-state. The findings and procedures described can be used to probe the pathophysiology of schizophrenia and possibly detect subtypes.展开更多
The spherical head model has been widely used in magnetoencephalography (MEG) as a simple forward model for calculating the external magnetic field producing by neural currents in a human brain. But this model may lea...The spherical head model has been widely used in magnetoencephalography (MEG) as a simple forward model for calculating the external magnetic field producing by neural currents in a human brain. But this model may lead to an inaccurate result, even if the computation speed is fast. For more precise computation, realistic brain-shaped head model is used with the boundary element method (BME), but at greatly increased computational cost. When solving MEG inverse problem by using optimization methods, the forward problem must often be solved for thousands of possible source configurations. So if the brain-shaped head model is used in all iterative steps of optimization, it may be computationally infeasible for practical application. In this paper, we present a method about using compound head model in MEG inverse solution. In this method, first spherical head model is used for a rough estimation, then brain-shaped head model is adopted for more precise solution. Numerical simulation indicates that under the condition of same accuracy, the computation speed for the present method is about three times faster than a method using the brain-shaped head model at all iterations.展开更多
Superconducting Quantum Interference Device (SQUID) can provide an ultrahigh magnetic sensitivity for the biomagnetic measurements. In this paper, a SQUID bootstrap circuit (SBC) gradiometer was designed and fabricate...Superconducting Quantum Interference Device (SQUID) can provide an ultrahigh magnetic sensitivity for the biomagnetic measurements. In this paper, a SQUID bootstrap circuit (SBC) gradiometer was designed and fabricated. Using the SBC gradiometer, magnetocardiography (MCG), fetal MCG and magnetoencephalography (MEG) signals were detected in a magnetically shielded room.展开更多
基金Project supported by Ji Hua Laboratory(Grant No.X190131TD190)the Research and Development Project for Equipment of Chinese Academy of Sciences(Grant No.YJKYYQ20210051)+1 种基金the Suzhou pilot project of basic research(Grant No.SJC2021024)the Natural Science Foundation of Jiangsu Province,China(Grant No.BK20200215)。
文摘Atomic magnetometers operated in the spin-exchange relaxation-free(SERF)regime are the promising sensor to replace superconducting quantum interference devices(SQUIDs)in the biomagnetism field.The SERF magnetometer with compact size and good performance is crucial to the new generation of wearable magnetoencephalography(MEG)system.In this paper,we developed a compact and closed-loop SERF magnetometer with the dimensions of 15.0×22.0×30.0 mm^(3)based on a single-beam configuration.The bandwidth of the magnetometer was extended to 675 Hz while the sensitivity was maintained at 22 f T/Hz^(1/2).A nearly 3-fold enhancement of the bandwidth was obtained in comparison with the open-loop control.The implementation of the closed-loop control also greatly improved the dynamic range,enabling the magnetometer to be robust against the disturbance of the ambient field.Moreover,the magnetometer was successfully applied for the detection of humanα-rhythm and auditory evoked fields(AEFs),which demonstrated the potential to be extended to multi-channel MEG measurements for future neuroscience studies.
文摘Previous studies examining coherence and connectivity deviations in schizophrenia patients relied on standard coherence measures between recording sites (at the sensor level). A coherence source imaging (CSI) methodology where coherence is assessed within imaged brain structures (at the source level) was developed recently by our group and applied successfully for detecting coherent areas in the cortical networks of patients with epilepsy. We applied this Magnetoencephalography (MEG)-CSI technique to measure normal and pathological patterns of brain oscillations (biomarkers) in normal subjects and patients diagnosed with schizophrenia. Twelve patients diagnosed with schizophrenia and twelve healthy control subjects were studied. A ten-minute resting state MEG brain scan was performed with eyes open. MEG-CSI analysis was performed to identify the cortical areas that interacted strongly within the 3 - 50 Hz frequency range. Statistically significant increased regions of coherence were detected in schizophrenia patients compared to controls in the right inferior frontal gyrus (BA 47—pars orbitalis), left superior frontal gyrus (BA9— dorsolateral prefrontal cortex), right middle frontal gyrus (BA 10—anterior prefrontal cortex & BA 46—dorsolateral prefrontal cortex), and right cingulate gyrus (BA 24—ventral anterior cingulate cortex). These areas are involved in language, memory, decision making, empathy, executive and, higher cognitive functioning. We conclude that MEG-CSI can detect imaging biomarkers from resting state brain activity in schizophrenia patients that deviates from normal control subjects in several behaviorally salient brain regions. Analysis with MEG-CSI can provide biomarkers of abnormalities in the resting-state. The findings and procedures described can be used to probe the pathophysiology of schizophrenia and possibly detect subtypes.
基金This work is supported by the National Natural Science Foundation of China(No.30 0 0 0 0 34 )
文摘The spherical head model has been widely used in magnetoencephalography (MEG) as a simple forward model for calculating the external magnetic field producing by neural currents in a human brain. But this model may lead to an inaccurate result, even if the computation speed is fast. For more precise computation, realistic brain-shaped head model is used with the boundary element method (BME), but at greatly increased computational cost. When solving MEG inverse problem by using optimization methods, the forward problem must often be solved for thousands of possible source configurations. So if the brain-shaped head model is used in all iterative steps of optimization, it may be computationally infeasible for practical application. In this paper, we present a method about using compound head model in MEG inverse solution. In this method, first spherical head model is used for a rough estimation, then brain-shaped head model is adopted for more precise solution. Numerical simulation indicates that under the condition of same accuracy, the computation speed for the present method is about three times faster than a method using the brain-shaped head model at all iterations.
基金supported by the Knowledge Innovation Program of the Chinese Academy of Sciences (KGCX2-YW-906, KGCX2-EW-105)"Hundred Talents Program" of the Chinese Academy of Sciences and Strategic Priority Research Program (B) of the Chinese Academy of Sciences (XRD04020300)
文摘Superconducting Quantum Interference Device (SQUID) can provide an ultrahigh magnetic sensitivity for the biomagnetic measurements. In this paper, a SQUID bootstrap circuit (SBC) gradiometer was designed and fabricated. Using the SBC gradiometer, magnetocardiography (MCG), fetal MCG and magnetoencephalography (MEG) signals were detected in a magnetically shielded room.