This paper presents the power hardware in the loop(PHIL)validation of a feed forward DC voltage control scheme for the fault ride through(FRT)of voltage source converter(VSC)high voltage DC(HVDC)connected offshore win...This paper presents the power hardware in the loop(PHIL)validation of a feed forward DC voltage control scheme for the fault ride through(FRT)of voltage source converter(VSC)high voltage DC(HVDC)connected offshore wind power plants(WPPs).In the proposed FRT scheme,the WPP collector network AC voltage is actively controlled by considering both the DC voltage error and the AC current from the WPP AC collector system which ensures fast and robust FRT of the VSC HVDC connected offshore WPPs.The PHIL tests were carried out in order to verify the efficacy of the proposed feed forward DC voltage control scheme for enhancing the FRT capability of the VSC HVDC connected WPPs.The PHIL test results have demonstrated the proper control coordination between the offshore WPP and the WPP side VSC and the efficient FRT of the VSC HVDC connected WPPs.展开更多
This letter studies large-disturbance stability of the power system with a synchronous generator(SG)and a converter-interfaced generation(CIG)connected to infinite bus.The power system is multi-timescale and first sim...This letter studies large-disturbance stability of the power system with a synchronous generator(SG)and a converter-interfaced generation(CIG)connected to infinite bus.The power system is multi-timescale and first simplified.It is shown that the boundary of region of attraction(ROA)of the simplified model is composed of stable manifolds of unstable equilibrium point(UEP)or semi-singular point(SSP),named anchor points,and singular surface pieces.The type of anchor point determines the dominant instability pattern of the power system.When the anchor point is UEP or SSP,the dominant instability pattern is the instability of rotor angle of SG or the instability of phase-locked loop and outer control loop(OCL)of CIG,respectively.Transition of dominant instability pattern can be analyzed with the relative position relationship between UEP and SSP.The effect of OCL is discussed.When the OCL is activated,the ROA becomes smaller and the system is more prone to instability of CIG.It is necessary to consider the OCL when studying the large-disturbance stability of the power system.展开更多
Voltage source converter based high-voltage direct current(VSC-HVDC)transmission technology has been extensively employed in power systems with a high penetration of renewable energy resources.However,connecting a vol...Voltage source converter based high-voltage direct current(VSC-HVDC)transmission technology has been extensively employed in power systems with a high penetration of renewable energy resources.However,connecting a voltage source converter(VSC)to an AC weak grid may cause the converter system to become unstable.In this paper,a phase-shift phaselocked loop(PS-PLL)is proposed wherein a back electromotive force(BEMF)observer is added to the conventional phaselocked loop(PLL).The BEMF observer is used to observe the voltage of the infinite grid in the stationaryαβframe,which avoids the problem of inaccurate observations of the grid voltage in the dq frame that are caused by the output phase angle errors of the PLL.The VSC using the PS-PLL can operate as if it is facing a strong grid,thus enhancing the stability of the VSC-HVDC system.The proposed PS-PLL only needs to be properly modified on the basis of a traditional PLL,which makes it easy to implement.In addition,because it is difficult to obtain the exact impedance of the grid,the influence of shortcircuit ratio(SCR)estimation errors on the performance of the PS-PLL is also studied.The effectiveness of the proposed PSPLL is verified by the small-signal stability analysis and timedomain simulation.展开更多
文摘This paper presents the power hardware in the loop(PHIL)validation of a feed forward DC voltage control scheme for the fault ride through(FRT)of voltage source converter(VSC)high voltage DC(HVDC)connected offshore wind power plants(WPPs).In the proposed FRT scheme,the WPP collector network AC voltage is actively controlled by considering both the DC voltage error and the AC current from the WPP AC collector system which ensures fast and robust FRT of the VSC HVDC connected offshore WPPs.The PHIL tests were carried out in order to verify the efficacy of the proposed feed forward DC voltage control scheme for enhancing the FRT capability of the VSC HVDC connected WPPs.The PHIL test results have demonstrated the proper control coordination between the offshore WPP and the WPP side VSC and the efficient FRT of the VSC HVDC connected WPPs.
基金supported by the National Natural Science Foundation of China(No.U2066602)。
文摘This letter studies large-disturbance stability of the power system with a synchronous generator(SG)and a converter-interfaced generation(CIG)connected to infinite bus.The power system is multi-timescale and first simplified.It is shown that the boundary of region of attraction(ROA)of the simplified model is composed of stable manifolds of unstable equilibrium point(UEP)or semi-singular point(SSP),named anchor points,and singular surface pieces.The type of anchor point determines the dominant instability pattern of the power system.When the anchor point is UEP or SSP,the dominant instability pattern is the instability of rotor angle of SG or the instability of phase-locked loop and outer control loop(OCL)of CIG,respectively.Transition of dominant instability pattern can be analyzed with the relative position relationship between UEP and SSP.The effect of OCL is discussed.When the OCL is activated,the ROA becomes smaller and the system is more prone to instability of CIG.It is necessary to consider the OCL when studying the large-disturbance stability of the power system.
基金supported by the National Natural Science Foundation of China(No.51677142)the National Key R&D Program of China(No.2016YFB0900600)。
文摘Voltage source converter based high-voltage direct current(VSC-HVDC)transmission technology has been extensively employed in power systems with a high penetration of renewable energy resources.However,connecting a voltage source converter(VSC)to an AC weak grid may cause the converter system to become unstable.In this paper,a phase-shift phaselocked loop(PS-PLL)is proposed wherein a back electromotive force(BEMF)observer is added to the conventional phaselocked loop(PLL).The BEMF observer is used to observe the voltage of the infinite grid in the stationaryαβframe,which avoids the problem of inaccurate observations of the grid voltage in the dq frame that are caused by the output phase angle errors of the PLL.The VSC using the PS-PLL can operate as if it is facing a strong grid,thus enhancing the stability of the VSC-HVDC system.The proposed PS-PLL only needs to be properly modified on the basis of a traditional PLL,which makes it easy to implement.In addition,because it is difficult to obtain the exact impedance of the grid,the influence of shortcircuit ratio(SCR)estimation errors on the performance of the PS-PLL is also studied.The effectiveness of the proposed PSPLL is verified by the small-signal stability analysis and timedomain simulation.