线型光束滤光片的校准
1
作者 何日梅 韦秋叶 +1 位作者 范晓辉 卢敏萍 《化学分析计量》 CAS 2021年第9期63-67,共5页
建立线型光束滤光片的校准方法。采用紫外、可见、近红外分光光度计作为计量标准装置,测量线型光束滤光片在800~1100 nm波长范围内的透射比,获得线型光束滤光片的减光值。分别给出线型光束滤光片均匀性、正反差别、年变化量等参考计量... 建立线型光束滤光片的校准方法。采用紫外、可见、近红外分光光度计作为计量标准装置,测量线型光束滤光片在800~1100 nm波长范围内的透射比,获得线型光束滤光片的减光值。分别给出线型光束滤光片均匀性、正反差别、年变化量等参考计量特性要求,减光值标称值小于1.0 dB时,均匀性、正反差别、年变化量不超过±0.03 dB,减光值标称值为10 dB时,均匀性、正反差别、年变化量均不超过±0.3 dB。分析测量过程的不确定度来源,并进行不确定度评定。减光值标称值小于1.0 dB和等于10 dB的线型光束滤光片,其减光值的扩展不确定度(k=2)分别为0.06 dB和0.6 dB。该校准方法考虑了线型光束滤光片的发展现状,使线型光束滤光片的校准有据可依,可用于线型光束滤光片的校准。 展开更多
关键词 线型光束滤光片 不确定度 减光值 均匀性 正反差别 年变化量 校准
下载PDF
Commissioning of TrueBeamTM Medical Linear Accelerator: Quantitative and Qualitative Dosimetric Analysis and Comparison of Flattening Filter (FF) and Flattening Filter Free (FFF) Beam 被引量:4
2
作者 Ravindra Shende Gourav Gupta +1 位作者 Ganesh Patel Senthil Kumar 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2016年第1期51-69,共19页
Motive of the study is to present quantitative and qualitative analysis and comparison of beam data measurement with FF (flattening filter) and FFF (flattening filter free) beam in a Varian TrueBeam<sup>TM</s... Motive of the study is to present quantitative and qualitative analysis and comparison of beam data measurement with FF (flattening filter) and FFF (flattening filter free) beam in a Varian TrueBeam<sup>TM</sup> Medical Linear Accelerator. Critique of beam characterization and evolution of dosimetric properties for 6 MV, 10 MV, 15 MV FF beam and 6 MVFFF, 10 MVFFF FFF beam has been carried out. We performed the comparison of photon beam data for two standard FF photon energy 6 MV, 10 MV verses 6 MVFFF, and 10 MVFFF FFF beam. Determination and comparison of parameter involved PDD (Percentage depth dose), Depth dose profile, Symmetry, Flatness, Quality index, Relative output factor, Penumbra, Transmission factor, DLG (Dosimetric leaf gap), in addition to degree of Un-flatness and off-axis ratio of FFF beam. Outcomes of presenting study had shown that change of various parameters such as Percentage depth dose curves, Shape of the depth dose profile, Transmission, Value of quality index and significant rise in surface dose for FFF in comparison with FF beam. Differences in the output factor at lower and higher field sizes for FFF beam compared to that of FF beam were found. The maximum output factor deviation between 6 MV and 6 MVFFF was found to be 4.55%, whereas in 10 MV and 10 MVFFF was 5.71%. Beam quality TPR20/10 for FFF beam was found to be lesser in magnitude, 5.42% for 6 MVFFF whereas 4.50% for 10 MVFFF compared to 6 MV and 10 MV FF beam respectively. Jaw transmission and interleaf leakage for FFF beam were found to be lesser than FF beam. Also DLG for FFF beam was found to be lesser in magnitude comparable to that of flattened beam. This study is mainly inclined towards evaluation and comparison of the FF and FFF beam. It has been observed that, the outcome of a commissioning beam data generation fully complies with vendor specification and published literature. 展开更多
关键词 True beam Medical linear Accelerator Commissioning Photon beam Data Flattening filter Flattening filter Free