A model of an energy selective electron (ESE) engine with linear heat leakage and Lorentzian transmission probability is established in this paper.The expressions for the main performance parameters of the ESE engine ...A model of an energy selective electron (ESE) engine with linear heat leakage and Lorentzian transmission probability is established in this paper.The expressions for the main performance parameters of the ESE engine operating as a heat engine or a refrigerator are derived by using the theory of finite time thermodynamics.The optimum performances of the ESE engine are explored and the influences of the heat leakage,the central energy level of the resonance,and the width of the resonance on the performance of the ESE engine are analyzed by using detailed numerical examples.The optimal operation regions of power output and efficiency (or cooling load and coefficient of performance (COP)) are also discussed.Moreover,the performances of the ESE engine with Lorentzian transmission probability are compared with those with rectangular transmission probability.It is shown that the power output versus efficiency (or cooling load versus COP) characteristic curves with and without heat leakage are all closed loop-shaped ones.The efficiency (or COP) of the ESE engine decreases as the heat leakage increases.It is found that as the resonance width increases,the power output and efficiency (or cooling load and COP) increase to a maximum and then decrease due to the finite range of energies which contribute positively to the power generation or refrigeration in the electron system.Especially,when heat leakage is taken into account,the characteristic curves of maximum efficiency (or maximum COP) versus half resonance width are parabolic-like ones,which are quite different from the monotonic decreasing characteristic curves obtained in previous analyses without considering heat leakage.The results obtained in this paper can provide some theoretical guidelines for the design and operation of practical electron energy conversion devices such as solid-state thermionic refrigerators.展开更多
Due to its flammable,explosive,and corrosive characteristics,fire,and explosion accidents caused by ammonia leakage occur from time to time.In this work,the concentration distribution of the model was calculated accor...Due to its flammable,explosive,and corrosive characteristics,fire,and explosion accidents caused by ammonia leakage occur from time to time.In this work,the concentration distribution of the model was calculated according to the existing formula of probabilistic risk assessment.Using the revised formulas,the leakage of the ammonia room was quantitatively analyzed,and different state parameters were analyzed to find out the dangerous leakage points of the ammonia refrigeration system.The results of the calculation are that the existence of obstacles in the space will increase the probability of leakage risk.And the greater the leakage time to the lower flammability limit accounts for the total leakage time,the greater the risk probability.Dangerous leakage in ammonia systems mainly occurs in storage tanks and condensers.The data show that the dynamic mass flow of ammonia leakage decreases with time,and the leakage diameter increases with the increase of leakage pressure.At the same time,the leakage mass increases gradually with the leakage aperture near circular.展开更多
基金supported by the National Natural Science Foundation of China (Grant No. 10905093)the Program for New Century Excellent Talents in Universities of China (Grant No. NCET-04-1006)the Foundation for the Author of National Excellent Doctoral Dissertation ofChina (Grant No. 200136)
文摘A model of an energy selective electron (ESE) engine with linear heat leakage and Lorentzian transmission probability is established in this paper.The expressions for the main performance parameters of the ESE engine operating as a heat engine or a refrigerator are derived by using the theory of finite time thermodynamics.The optimum performances of the ESE engine are explored and the influences of the heat leakage,the central energy level of the resonance,and the width of the resonance on the performance of the ESE engine are analyzed by using detailed numerical examples.The optimal operation regions of power output and efficiency (or cooling load and coefficient of performance (COP)) are also discussed.Moreover,the performances of the ESE engine with Lorentzian transmission probability are compared with those with rectangular transmission probability.It is shown that the power output versus efficiency (or cooling load versus COP) characteristic curves with and without heat leakage are all closed loop-shaped ones.The efficiency (or COP) of the ESE engine decreases as the heat leakage increases.It is found that as the resonance width increases,the power output and efficiency (or cooling load and COP) increase to a maximum and then decrease due to the finite range of energies which contribute positively to the power generation or refrigeration in the electron system.Especially,when heat leakage is taken into account,the characteristic curves of maximum efficiency (or maximum COP) versus half resonance width are parabolic-like ones,which are quite different from the monotonic decreasing characteristic curves obtained in previous analyses without considering heat leakage.The results obtained in this paper can provide some theoretical guidelines for the design and operation of practical electron energy conversion devices such as solid-state thermionic refrigerators.
基金supported by the State Key Program of the National Natural Science Foundation of China(Grant No.51936007)。
文摘Due to its flammable,explosive,and corrosive characteristics,fire,and explosion accidents caused by ammonia leakage occur from time to time.In this work,the concentration distribution of the model was calculated according to the existing formula of probabilistic risk assessment.Using the revised formulas,the leakage of the ammonia room was quantitatively analyzed,and different state parameters were analyzed to find out the dangerous leakage points of the ammonia refrigeration system.The results of the calculation are that the existence of obstacles in the space will increase the probability of leakage risk.And the greater the leakage time to the lower flammability limit accounts for the total leakage time,the greater the risk probability.Dangerous leakage in ammonia systems mainly occurs in storage tanks and condensers.The data show that the dynamic mass flow of ammonia leakage decreases with time,and the leakage diameter increases with the increase of leakage pressure.At the same time,the leakage mass increases gradually with the leakage aperture near circular.