This survey was designed to assess the sanitation status of hospitals and the compliance of hospital staff to disinfection strategies within the past 11 years.A total of 199 provincial affiliated tertiary or secondary...This survey was designed to assess the sanitation status of hospitals and the compliance of hospital staff to disinfection strategies within the past 11 years.A total of 199 provincial affiliated tertiary or secondary public hospitals from 2007 to 2017 were investigated and seven critical categories,namely indoor air,work surface,hand hygiene,ultraviolet(UV) irradiation intensity,use of disinfectants,sterilization of medical items,and effects of steam sterilizer,were monitored.The average qualified rates were(94.74±3.54)%(810/855),(97.25±1.65)%(1 876/1 929),(87.57±4.60)%(2 508/2 864),(95.00±4.50)%(1 196/1 259),and(98.76±1.14)%(1 599/1 619) for indoor air,work surface,hand hygiene,UV irradiation intensity,and sterilization of medical items,respectively.In terms of other categories,a few samples were not qualified:3/1 575 for use of disinfectants and 1/243 for effects of steam sterilizer.The hospital disinfection monitoring and supervision program effectively improved the effectiveness of disinfection.Routine monitoring and supervision must be conducted to ensure a safe hospital treatment environment.展开更多
辐射屏蔽计算是核电厂辐射防护设计和审评的重要内容之一。国际屏蔽计算软件对中国实行"出口封锁",制约了我国核电辐射屏蔽审核计算能力,因此,研发了具有自主知识产权的基于蒙特卡罗方法的辐射屏蔽专用蒙特卡罗软件RShieldMC(...辐射屏蔽计算是核电厂辐射防护设计和审评的重要内容之一。国际屏蔽计算软件对中国实行"出口封锁",制约了我国核电辐射屏蔽审核计算能力,因此,研发了具有自主知识产权的基于蒙特卡罗方法的辐射屏蔽专用蒙特卡罗软件RShieldMC(Radiation Shielding Monte Carlo)。为了验证RShieldMC程序,进行中子注量率计算的准确性和适用性,利用秦山一期反应堆结构与辐照监督管相关参数,通过RShieldMC可视化前处理模块建立辐照监督管屏蔽计算模型,计算秦山一期反应堆辐照监督管堆芯中平面和上焊缝处的中子注量率。RShieldMC程序计算结果与辐照监督管实验测量值以及MCNP(Monte Carlo N-Particle)、JMCT-S(J Monte Carlo Transport)、TORT(Three-dimensional Neutron/Photon Transport)程序计算结果符合较好,验证了RShieldMC软件在中子注量率计算中的可用性及正确性。展开更多
文摘This survey was designed to assess the sanitation status of hospitals and the compliance of hospital staff to disinfection strategies within the past 11 years.A total of 199 provincial affiliated tertiary or secondary public hospitals from 2007 to 2017 were investigated and seven critical categories,namely indoor air,work surface,hand hygiene,ultraviolet(UV) irradiation intensity,use of disinfectants,sterilization of medical items,and effects of steam sterilizer,were monitored.The average qualified rates were(94.74±3.54)%(810/855),(97.25±1.65)%(1 876/1 929),(87.57±4.60)%(2 508/2 864),(95.00±4.50)%(1 196/1 259),and(98.76±1.14)%(1 599/1 619) for indoor air,work surface,hand hygiene,UV irradiation intensity,and sterilization of medical items,respectively.In terms of other categories,a few samples were not qualified:3/1 575 for use of disinfectants and 1/243 for effects of steam sterilizer.The hospital disinfection monitoring and supervision program effectively improved the effectiveness of disinfection.Routine monitoring and supervision must be conducted to ensure a safe hospital treatment environment.
文摘辐射屏蔽计算是核电厂辐射防护设计和审评的重要内容之一。国际屏蔽计算软件对中国实行"出口封锁",制约了我国核电辐射屏蔽审核计算能力,因此,研发了具有自主知识产权的基于蒙特卡罗方法的辐射屏蔽专用蒙特卡罗软件RShieldMC(Radiation Shielding Monte Carlo)。为了验证RShieldMC程序,进行中子注量率计算的准确性和适用性,利用秦山一期反应堆结构与辐照监督管相关参数,通过RShieldMC可视化前处理模块建立辐照监督管屏蔽计算模型,计算秦山一期反应堆辐照监督管堆芯中平面和上焊缝处的中子注量率。RShieldMC程序计算结果与辐照监督管实验测量值以及MCNP(Monte Carlo N-Particle)、JMCT-S(J Monte Carlo Transport)、TORT(Three-dimensional Neutron/Photon Transport)程序计算结果符合较好,验证了RShieldMC软件在中子注量率计算中的可用性及正确性。