Four 20-membered N_2S_4-monoazathiacrown ethers have been synthesized and explored as neutral ionophores for Ag^+-selective electrodes.Potentiometric responses reveal that the flexibility of the ligands has great effe...Four 20-membered N_2S_4-monoazathiacrown ethers have been synthesized and explored as neutral ionophores for Ag^+-selective electrodes.Potentiometric responses reveal that the flexibility of the ligands has great effect on the selectivity and sensitivity to Ag^+ ions.The electrode based on ionophore 9,10,20,25-tetrahydro-5H,12H-tribenzo[b,n,r][1,7,10,16,4,13]tetrathiadiaza cycloicosine 6,13-(7H,14H)-dione(C) with 2-nitrophenyl octyl ether(o-NPOE) as solvent in a poly(vinyl chloride)(PVC) membrane matrix sho...展开更多
Total or near-total fertilization failure after intracytoplasmic sperm injection (ICSl) is a rare event, but it occurs repeatedly because of sperm defects in activating oocyte. The case presents a successful pregnan...Total or near-total fertilization failure after intracytoplasmic sperm injection (ICSl) is a rare event, but it occurs repeatedly because of sperm defects in activating oocyte. The case presents a successful pregnancy and live birth after calcium ionophore A23187 (A23187) activation on one-day-old unfertilized oocytes in a patient whose husband suffered oligoasthenoteratozoospermia, and who had experienced repeated near-total fertilization failure after ICSI. In the second ICSI cycle, only one oocyte was fertilized while nine were unfertilized. Oocyte activation with A23187 were performed on the one-day-old unfertilized oocytes after ICSI and resulted in fertilization and embryo transfer. A clinical pregnancy was achieved and a healthy baby was born. To our knowledge, this is the first reported case of a healthy birth after oocyte activation on the one-day-old unfertilized oocyte. This indicates that "rescue oocyte activation" on one-day-old unfertilized oocytes after ICSI may be helpful for preventing total or near-total fertilization failure after ICSI.展开更多
A new chemically modified carbon paste electrode for cesium(I) ion determination based on potassium zinc hexacyan-oferrate (PZHCF) as an ionophore was prepared. The electrode exhibits a Nernstian response for Cs(I) io...A new chemically modified carbon paste electrode for cesium(I) ion determination based on potassium zinc hexacyan-oferrate (PZHCF) as an ionophore was prepared. The electrode exhibits a Nernstian response for Cs(I) ions over a wide concentration range from 1 × 10-6 to 1 × 10-1 mol·L-1 with a slope of 58 ± 0.5 mV·decade-1. It has a response time of about 35 s and can be used for a period of 3 months with good reproducibility. Detection limit obtained in the optimal conditions was 3 × 10-7 mol·L-1. The potentiometric response is independent of the pH of the solution in the pH range 4.0 - 8.0. The electrode possesses the advantages of low resistance, fast response over a variety of other cations. The proposed electrode is applied as a sensor for the determination of Cs(I) ion concentration in different samples solutions. The results showed a good correlation with the data obtained by atomic absorption spectrometric method.展开更多
The combination of intracytoplasmic sperm injection (ICSI) with artificial oocyte activation has overcome repeated fertilization failure after ICSI due to sperm defects in activating oocyte, resulting in pregnancies...The combination of intracytoplasmic sperm injection (ICSI) with artificial oocyte activation has overcome repeated fertilization failure after ICSI due to sperm defects in activating oocyte, resulting in pregnancies and births for many couples. However, in comparison to the growing data illustrating the effectiveness of artificial oocyte activation in reproductive medicine, the safety of this approach has not been well studied. Previously,展开更多
Three novel amprolium HCl(AMP)-selective electrodes were investigated with 2-nitrophenyl octylether as a plasticiser in a polymeric matrix of polyvinyl chloride(PVC). Sensor I was fabricated using potassium tetra...Three novel amprolium HCl(AMP)-selective electrodes were investigated with 2-nitrophenyl octylether as a plasticiser in a polymeric matrix of polyvinyl chloride(PVC). Sensor I was fabricated using potassium tetrakis(4-chlorophenyl) borate(Tp ClPB) as a cationic exchanger without incorporation of an ionophore.Sensor Ⅱ used 2-hydroxy propyl β-cyclodextrin as an ionophore while sensor Ⅲ used p-tert-butylcalix[8]arene as an ionophore. The three proposed sensors showed Nernestian response slopes of 29.2±0.8,29.3±0.6 and 30.2±0.4 m V/decade over the concentration range from 10–6 to 10–2 mol L_(-1),respectively. The proposed sensors displayed useful analytical characteristics for the determination of AMP in bulk powder, different pharmaceutical formulations, and chicken liver and in the presence of ethopabate. The proposed method was validated according to ICH guidelines for its linearity, accuracy,precision and robustness.展开更多
A thiocyanate ion selective poly(aniline) solid contact electrode based on manganese complex of N,N’-bis-(4-phenylazosalicylidene)-o-phenylene diamine ionophore was successfully developed. The electrode exhibits a go...A thiocyanate ion selective poly(aniline) solid contact electrode based on manganese complex of N,N’-bis-(4-phenylazosalicylidene)-o-phenylene diamine ionophore was successfully developed. The electrode exhibits a good linear response of 58.1 mV/decade (at 20?C ± 0.2?C, r2 = 0.998) with in the concentration range of 1 × 10–1.0 ~ 1 × 10–5.8 M thiocyanate solution. The composition of this electrode was: ionophore 0.040, polyvinylchloride 0.300, dibutylphthalate 0.660 (mass). This dibutylphthalate plasticizer provides the best response characteristics. The electrode shows good selectivity for thiocyanate ion in comparison with any other anions and is suitable for use with aqueous solutions of pH 4.0 ~ 6.0. The standard deviations of the measured emf difference were ±1.70 and ±2.01 mV for thiocyanate sample solutions of 1.0 × 10–2 M and 1.0 × 10–3 M, respectively. The stabilization time was less than 170 sec. and response time was less than 17 sec.展开更多
Timing of vegetal-endodermal cell determination in amphioxus embryos remains uncertain. We tentatively testal effects of A23187, the calcium ionophore, on the deveopment of vegetal blastomeres isolated at the 16-cell ...Timing of vegetal-endodermal cell determination in amphioxus embryos remains uncertain. We tentatively testal effects of A23187, the calcium ionophore, on the deveopment of vegetal blastomeres isolated at the 16-cell stage. It was found that when vegetal blastomres committed to endodermwere treated with A23187 prior to gastrulation, they were transformed into ectodermal cells as evidenced by the cell morphology and function characteristic of epidermis. Howver, the developmental fate of the sam blastomeres untreated or treated with DMSO at the same stage or of those treated with A23187 after gastrulation remained unchanged. Thus, vegetal-endodermal cells in amphioxus embryos are not irreversibly deermined before the gastrula stage, and artificial incarease in intracelluar Ca2+ concentration can induce transdetermination of the predetermined endodermal cells into ectodermal cells.展开更多
A new type of di benzoyl tartaric acid selective electr ode has been developed. Three double\| arm calixarene derivatives were emp loyed as the neutral ionophores. The poly(vinyl chloride) me...A new type of di benzoyl tartaric acid selective electr ode has been developed. Three double\| arm calixarene derivatives were emp loyed as the neutral ionophores. The poly(vinyl chloride) membrane electrode containing an amide derivative of ca lixarene as the neutral carrier an d a dibutyl phthalate as the plastici zer exhibited the highest sensitivity for dibenzoyl tartaric acid. The slop e of linear portion was 27.8 mV per c oncertration decade. The electrode has a fast response and a long lifetime .展开更多
We use the extended gate field effect transistor (EGFET)as the structure of the chlorine ion sensor,and the chlorine ion ionophores (ETH9033 and TDDMAC1)are incorporated into solvent polymeric membrane (PVC/DOS),then ...We use the extended gate field effect transistor (EGFET)as the structure of the chlorine ion sensor,and the chlorine ion ionophores (ETH9033 and TDDMAC1)are incorporated into solvent polymeric membrane (PVC/DOS),then the chlorine ion selective membrane is formed on the sensing window,and the fabrication of the EGFET chlorine ion sensing device is completed.The surface potential on the sensing membrane of the EGFET chlorine ion sensing device will be changed in the different chlorine ion concentration solutions,then changes further gate voltage and drain current to detect chlorine ion concentration.We will study non-ideal effects such as temperature,hysteresis and drift effects for the EGFET chlorine ion sensing device in this paper,these researches will help us to improve the sensing characteristics of the EGFET chlorine ion sensing device.展开更多
Macrocyclic compounds,such as crown ethers,azacrown ethers,thiacrown ethers,calixarenes and porphyrins,which act as ionophores in lead(Ⅱ) ion-selective electrodes,are systematically summarized based on the latest lit...Macrocyclic compounds,such as crown ethers,azacrown ethers,thiacrown ethers,calixarenes and porphyrins,which act as ionophores in lead(Ⅱ) ion-selective electrodes,are systematically summarized based on the latest literatures.The molecular structure characteristics of the ionophores are general-ized.The modification regulations for the substituted ionophores are elaborated with the purpose of improving the response features of the lead(Ⅱ) ion-selective electrodes assembled by them.It is pointed out that the introduction of pendant moieties which contain soft base coordination centers like N,S and P atoms is in favor of adjusting the cavity size and conformation of the macrocyclic com-pounds.Furthermore,there is synergic effect between the cavity and the donor sites of the ligand and thus the selective complexation of lead ions is easily realized,resulting in significant avoidance of the interference from other metal ions.The macrocyclic ionophore having the best response characteris-tics thus far was found to be N,N'-dimethylcyanodiaza-18-crown-6 with the detection limit of 7.0×10-8(14.5 μg/L),which is one of the uncommon ionophores that can really eliminate the interference from silver and mercury ions.The selectivity coefficients of the ionophore for lead ions over other metal ions,such as alkali,alkaline earth and transition metal ions are in the order of 10-4 or smaller,where the se-lectivity coefficient of lead(Ⅱ) over mercury(Ⅱ) ions is much lower,down to 8.9×10-4.The structure de-sign idea for high-performance ionophore is proposed according to present results.The incorporation of nitrogen atom,especially cyano group or thiocyano group or amino/imino groups,rather than thio atom alone could result in new excellent lead ionophores.The aborative design for metacyclophanes containing aromatic nitrogen atoms with the aim of creating excellent ionophores would also become a potential research trend.The lead(Ⅱ) ion-selective electrodes have shown widely potential applications in the potentiometric ti展开更多
The release of mediators from mast cells is a model for cell secretion and is an in-vitro index for immediate hypersensitivity reactions. Calcium influx is generally accepted to be the primary biochemicalevent in mast...The release of mediators from mast cells is a model for cell secretion and is an in-vitro index for immediate hypersensitivity reactions. Calcium influx is generally accepted to be the primary biochemicalevent in mast cell activation.We studied the effect of the calcium ionophore A 23187 and calcium channelblockers,nifedipine and verapamil, in triggering the activation of rat peritoneal mast cells.At suitableconcentration nifedipine and verapamil have had the inhibition effect in the IgE-dependent roaction.展开更多
<strong>Objectives:</strong><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> Evaluate the effect of ...<strong>Objectives:</strong><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> Evaluate the effect of artificial oocyte activation (AOA) using calcium ionophore (A23187) on the rate of fertilization and cleavage of embryos in surgically retrieved sperm of patients with non-obstructive azoospermia undergoing intracytoplasmic sperm injection (ICSI).</span></span></span><span><span><span style="font-family:""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><b><span style="font-family:Verdana;">Study design: </span></b></span></span><span><span><span style="font-family:""><span style="font-family:Verdana;">This study was conducted on 60 infertile couples undergoing ICSI cycles as a randomized controlled parallel group’s experimental study in a private IVF center in Egypt from January 2018 to July 2019. ICSI cycles were divided into two g</span><span style="font-family:Verdana;">roups: Group A: includes 30 ICSI patients with surgically retrieved sperms of non-obstructive azoospermia treated with calcium ionophore (A23187). Group C/Control: includes 30 ICSI patients with surgically retrieved sperms of non-obstructive azoospermia non-treated with calcium ionophore (A23187)</span><span style="font-family:Verdana;">. </span><b><span style="font-family:Verdana;">Results: </span></b><span style="font-family:Verdana;">There was no statistical difference between both groups regarding the fertilization rate (</span><i><span style="font-family:Verdana;">p</span></i><span style="font-family:Verdana;"> = 0.853). There was no statistical difference between them regarding implantation rate (</span><i><span style="font-family:Verdana;">p</span></i><span style="font-family:Verdana;"> = 0.237). The percentage of Class A embryos in the ca ionophore group was 81.7%, while it was 82.8% in the control group. There was insignificant difference between them (</span><i><span style="font-family:Verdana;">p</span></i><span style="font-family:Ve展开更多
Ionophore can prominently improve the ion permeability of cell membrane and disrupt cellular ion homeostasis.Most studies regarding ionophore facilitating ion transmembrane transport focus on artificial liquid-liquid ...Ionophore can prominently improve the ion permeability of cell membrane and disrupt cellular ion homeostasis.Most studies regarding ionophore facilitating ion transmembrane transport focus on artificial liquid-liquid interfaces,which have large difference from the actual environment of cell membrane.Here,we construct a supported lipid bilayeron a gold nanoparticles film modified ZnSe prism as an appropriate model of cell membrane to investigate the dynamic of the ion transport facilitated by ionophore using surface enhanced infrared absorption spectroscopy(SEIRAS).We find that the ion transmembrane transport consists of two steps:The ion transmembrane transport starts with the association/disassociation between ion and ionophore at the edge of lipid bilayer;The second step is the transfer of ion-ionophore complex across lipid bilayer.Our results show that the complex transfer across the lipid bilayer is the rate determining step.展开更多
基金supported by the Chinese Academy of Sciences(No.KZCX2-YW-410)the National Natural Science Foundation of China(No.40776058)+1 种基金the National 863 High Technology Project of the Ministry of Science and Technology of China(No.2007AA09Z103)the Outstanding Youth Natural Science Foundation of Shandong Province(No.JQ200814)
文摘Four 20-membered N_2S_4-monoazathiacrown ethers have been synthesized and explored as neutral ionophores for Ag^+-selective electrodes.Potentiometric responses reveal that the flexibility of the ligands has great effect on the selectivity and sensitivity to Ag^+ ions.The electrode based on ionophore 9,10,20,25-tetrahydro-5H,12H-tribenzo[b,n,r][1,7,10,16,4,13]tetrathiadiaza cycloicosine 6,13-(7H,14H)-dione(C) with 2-nitrophenyl octyl ether(o-NPOE) as solvent in a poly(vinyl chloride)(PVC) membrane matrix sho...
文摘Total or near-total fertilization failure after intracytoplasmic sperm injection (ICSl) is a rare event, but it occurs repeatedly because of sperm defects in activating oocyte. The case presents a successful pregnancy and live birth after calcium ionophore A23187 (A23187) activation on one-day-old unfertilized oocytes in a patient whose husband suffered oligoasthenoteratozoospermia, and who had experienced repeated near-total fertilization failure after ICSI. In the second ICSI cycle, only one oocyte was fertilized while nine were unfertilized. Oocyte activation with A23187 were performed on the one-day-old unfertilized oocytes after ICSI and resulted in fertilization and embryo transfer. A clinical pregnancy was achieved and a healthy baby was born. To our knowledge, this is the first reported case of a healthy birth after oocyte activation on the one-day-old unfertilized oocyte. This indicates that "rescue oocyte activation" on one-day-old unfertilized oocytes after ICSI may be helpful for preventing total or near-total fertilization failure after ICSI.
文摘A new chemically modified carbon paste electrode for cesium(I) ion determination based on potassium zinc hexacyan-oferrate (PZHCF) as an ionophore was prepared. The electrode exhibits a Nernstian response for Cs(I) ions over a wide concentration range from 1 × 10-6 to 1 × 10-1 mol·L-1 with a slope of 58 ± 0.5 mV·decade-1. It has a response time of about 35 s and can be used for a period of 3 months with good reproducibility. Detection limit obtained in the optimal conditions was 3 × 10-7 mol·L-1. The potentiometric response is independent of the pH of the solution in the pH range 4.0 - 8.0. The electrode possesses the advantages of low resistance, fast response over a variety of other cations. The proposed electrode is applied as a sensor for the determination of Cs(I) ion concentration in different samples solutions. The results showed a good correlation with the data obtained by atomic absorption spectrometric method.
文摘The combination of intracytoplasmic sperm injection (ICSI) with artificial oocyte activation has overcome repeated fertilization failure after ICSI due to sperm defects in activating oocyte, resulting in pregnancies and births for many couples. However, in comparison to the growing data illustrating the effectiveness of artificial oocyte activation in reproductive medicine, the safety of this approach has not been well studied. Previously,
文摘Three novel amprolium HCl(AMP)-selective electrodes were investigated with 2-nitrophenyl octylether as a plasticiser in a polymeric matrix of polyvinyl chloride(PVC). Sensor I was fabricated using potassium tetrakis(4-chlorophenyl) borate(Tp ClPB) as a cationic exchanger without incorporation of an ionophore.Sensor Ⅱ used 2-hydroxy propyl β-cyclodextrin as an ionophore while sensor Ⅲ used p-tert-butylcalix[8]arene as an ionophore. The three proposed sensors showed Nernestian response slopes of 29.2±0.8,29.3±0.6 and 30.2±0.4 m V/decade over the concentration range from 10–6 to 10–2 mol L_(-1),respectively. The proposed sensors displayed useful analytical characteristics for the determination of AMP in bulk powder, different pharmaceutical formulations, and chicken liver and in the presence of ethopabate. The proposed method was validated according to ICH guidelines for its linearity, accuracy,precision and robustness.
文摘A thiocyanate ion selective poly(aniline) solid contact electrode based on manganese complex of N,N’-bis-(4-phenylazosalicylidene)-o-phenylene diamine ionophore was successfully developed. The electrode exhibits a good linear response of 58.1 mV/decade (at 20?C ± 0.2?C, r2 = 0.998) with in the concentration range of 1 × 10–1.0 ~ 1 × 10–5.8 M thiocyanate solution. The composition of this electrode was: ionophore 0.040, polyvinylchloride 0.300, dibutylphthalate 0.660 (mass). This dibutylphthalate plasticizer provides the best response characteristics. The electrode shows good selectivity for thiocyanate ion in comparison with any other anions and is suitable for use with aqueous solutions of pH 4.0 ~ 6.0. The standard deviations of the measured emf difference were ±1.70 and ±2.01 mV for thiocyanate sample solutions of 1.0 × 10–2 M and 1.0 × 10–3 M, respectively. The stabilization time was less than 170 sec. and response time was less than 17 sec.
文摘Timing of vegetal-endodermal cell determination in amphioxus embryos remains uncertain. We tentatively testal effects of A23187, the calcium ionophore, on the deveopment of vegetal blastomeres isolated at the 16-cell stage. It was found that when vegetal blastomres committed to endodermwere treated with A23187 prior to gastrulation, they were transformed into ectodermal cells as evidenced by the cell morphology and function characteristic of epidermis. Howver, the developmental fate of the sam blastomeres untreated or treated with DMSO at the same stage or of those treated with A23187 after gastrulation remained unchanged. Thus, vegetal-endodermal cells in amphioxus embryos are not irreversibly deermined before the gastrula stage, and artificial incarease in intracelluar Ca2+ concentration can induce transdetermination of the predetermined endodermal cells into ectodermal cells.
文摘A new type of di benzoyl tartaric acid selective electr ode has been developed. Three double\| arm calixarene derivatives were emp loyed as the neutral ionophores. The poly(vinyl chloride) membrane electrode containing an amide derivative of ca lixarene as the neutral carrier an d a dibutyl phthalate as the plastici zer exhibited the highest sensitivity for dibenzoyl tartaric acid. The slop e of linear portion was 27.8 mV per c oncertration decade. The electrode has a fast response and a long lifetime .
文摘We use the extended gate field effect transistor (EGFET)as the structure of the chlorine ion sensor,and the chlorine ion ionophores (ETH9033 and TDDMAC1)are incorporated into solvent polymeric membrane (PVC/DOS),then the chlorine ion selective membrane is formed on the sensing window,and the fabrication of the EGFET chlorine ion sensing device is completed.The surface potential on the sensing membrane of the EGFET chlorine ion sensing device will be changed in the different chlorine ion concentration solutions,then changes further gate voltage and drain current to detect chlorine ion concentration.We will study non-ideal effects such as temperature,hysteresis and drift effects for the EGFET chlorine ion sensing device in this paper,these researches will help us to improve the sensing characteristics of the EGFET chlorine ion sensing device.
基金the National Natural Science Foundation of China (Grant No. 20774065)
文摘Macrocyclic compounds,such as crown ethers,azacrown ethers,thiacrown ethers,calixarenes and porphyrins,which act as ionophores in lead(Ⅱ) ion-selective electrodes,are systematically summarized based on the latest literatures.The molecular structure characteristics of the ionophores are general-ized.The modification regulations for the substituted ionophores are elaborated with the purpose of improving the response features of the lead(Ⅱ) ion-selective electrodes assembled by them.It is pointed out that the introduction of pendant moieties which contain soft base coordination centers like N,S and P atoms is in favor of adjusting the cavity size and conformation of the macrocyclic com-pounds.Furthermore,there is synergic effect between the cavity and the donor sites of the ligand and thus the selective complexation of lead ions is easily realized,resulting in significant avoidance of the interference from other metal ions.The macrocyclic ionophore having the best response characteris-tics thus far was found to be N,N'-dimethylcyanodiaza-18-crown-6 with the detection limit of 7.0×10-8(14.5 μg/L),which is one of the uncommon ionophores that can really eliminate the interference from silver and mercury ions.The selectivity coefficients of the ionophore for lead ions over other metal ions,such as alkali,alkaline earth and transition metal ions are in the order of 10-4 or smaller,where the se-lectivity coefficient of lead(Ⅱ) over mercury(Ⅱ) ions is much lower,down to 8.9×10-4.The structure de-sign idea for high-performance ionophore is proposed according to present results.The incorporation of nitrogen atom,especially cyano group or thiocyano group or amino/imino groups,rather than thio atom alone could result in new excellent lead ionophores.The aborative design for metacyclophanes containing aromatic nitrogen atoms with the aim of creating excellent ionophores would also become a potential research trend.The lead(Ⅱ) ion-selective electrodes have shown widely potential applications in the potentiometric ti
文摘The release of mediators from mast cells is a model for cell secretion and is an in-vitro index for immediate hypersensitivity reactions. Calcium influx is generally accepted to be the primary biochemicalevent in mast cell activation.We studied the effect of the calcium ionophore A 23187 and calcium channelblockers,nifedipine and verapamil, in triggering the activation of rat peritoneal mast cells.At suitableconcentration nifedipine and verapamil have had the inhibition effect in the IgE-dependent roaction.
文摘<strong>Objectives:</strong><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> Evaluate the effect of artificial oocyte activation (AOA) using calcium ionophore (A23187) on the rate of fertilization and cleavage of embryos in surgically retrieved sperm of patients with non-obstructive azoospermia undergoing intracytoplasmic sperm injection (ICSI).</span></span></span><span><span><span style="font-family:""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><b><span style="font-family:Verdana;">Study design: </span></b></span></span><span><span><span style="font-family:""><span style="font-family:Verdana;">This study was conducted on 60 infertile couples undergoing ICSI cycles as a randomized controlled parallel group’s experimental study in a private IVF center in Egypt from January 2018 to July 2019. ICSI cycles were divided into two g</span><span style="font-family:Verdana;">roups: Group A: includes 30 ICSI patients with surgically retrieved sperms of non-obstructive azoospermia treated with calcium ionophore (A23187). Group C/Control: includes 30 ICSI patients with surgically retrieved sperms of non-obstructive azoospermia non-treated with calcium ionophore (A23187)</span><span style="font-family:Verdana;">. </span><b><span style="font-family:Verdana;">Results: </span></b><span style="font-family:Verdana;">There was no statistical difference between both groups regarding the fertilization rate (</span><i><span style="font-family:Verdana;">p</span></i><span style="font-family:Verdana;"> = 0.853). There was no statistical difference between them regarding implantation rate (</span><i><span style="font-family:Verdana;">p</span></i><span style="font-family:Verdana;"> = 0.237). The percentage of Class A embryos in the ca ionophore group was 81.7%, while it was 82.8% in the control group. There was insignificant difference between them (</span><i><span style="font-family:Verdana;">p</span></i><span style="font-family:Ve
基金supported by grants from the National Key R&D Program of China(No.2017YFA0700500)the National Natural Science Foundation of China(No.21635004)。
文摘Ionophore can prominently improve the ion permeability of cell membrane and disrupt cellular ion homeostasis.Most studies regarding ionophore facilitating ion transmembrane transport focus on artificial liquid-liquid interfaces,which have large difference from the actual environment of cell membrane.Here,we construct a supported lipid bilayeron a gold nanoparticles film modified ZnSe prism as an appropriate model of cell membrane to investigate the dynamic of the ion transport facilitated by ionophore using surface enhanced infrared absorption spectroscopy(SEIRAS).We find that the ion transmembrane transport consists of two steps:The ion transmembrane transport starts with the association/disassociation between ion and ionophore at the edge of lipid bilayer;The second step is the transfer of ion-ionophore complex across lipid bilayer.Our results show that the complex transfer across the lipid bilayer is the rate determining step.