The three-dimensional spatial and temporal development of impulsive VHF radiation events during lightning discharges has been analyzed based on the data measured by the lightning mapping array (LMA) system with high s...The three-dimensional spatial and temporal development of impulsive VHF radiation events during lightning discharges has been analyzed based on the data measured by the lightning mapping array (LMA) system with high space and time resolution. The results indicate that intracloud discharges in the thunderstorm with a normal tripole charge structure occur not only between the upper positive and middle main negative charge region, but also with inverted polarity between the lower positive and middle main negative charge region. The polarity-inverted discharge originates from the middle negative charge and propagates downward to the lower positive region, where then the discharge develops horizontally. The characteristics of the discharge are similar to that of normal intracloud discharge except the polarity opposite. The results further confirmed the existence of the lower positive charge region involved in the lightning discharge. It was also found that the inverted charge structure opposite to the展开更多
Data from the Beijing SAFIR 3000 lightning detection system and Doppler radar provided some insights into the three-dimensional lightning structure and evolution of a leading-line and trailing-stratiform (LLTS) meso...Data from the Beijing SAFIR 3000 lightning detection system and Doppler radar provided some insights into the three-dimensional lightning structure and evolution of a leading-line and trailing-stratiform (LLTS) mesoscale convective system (MCS) over Beijing on 31 July 2007. Most of the lightning in the LLTS-MCS was intracloud (IC) lightning, while the mean ratio of positive cloud-to-ground (+CG) lightning to –CG lightning was 1:4, which was higher than the average value from previous studies. The majority of CG lightning occurred in the convective region of the radar echo, particularly at the leading edge of the front. Little IC lightning and little +CG lightning occurred in the stratiform region. The distribution of the CG lightning indicated that the storm had a tilted dipole structure given the wind shear or the tripole charge structure. During the storm’s development, most of the IC lightning occurred at an altitude of ~9.5 km; the lightning rate reached its maximum at 10.5 km, the altitude of IC lightning in the mature stage of the storm. When the thunderstorm began to dissipate, the altitude of the IC lightning decreased gradually. The spatial distribution of lightning was well correlated with the rainfall on the ground, although the peak value of rainfall appeared 75 min later than the peak lightning rate.展开更多
From analysis of observational data of thunderstorms in Gansu,China,it was deduced that the electric structure of thunderclouds in this region is often positive charge in the upper,main negative in the middle layer an...From analysis of observational data of thunderstorms in Gansu,China,it was deduced that the electric structure of thunderclouds in this region is often positive charge in the upper,main negative in the middle layer and another positive charge,large in magnitude and extensive in dimension,in the lower part.Intra- cloud discharges often take place between the main negative charge and lower positive charge instead of upper. Case analysis of 6 intracloud discharges in two storms on August 3 and 4,1986 shows that the centers of these discharges and the dipole moments destroyed were at the altitude of 3.8—6 km msl(7.6—-13.5℃)and 18— 40 C km,respectively.展开更多
From January 2020 to December 2021,Ulanqab Meteorological Bureau of Inner Mongolia used VLF/LF lightning locator to carry out three-dimensional lightning monitoring in Ulanqab City,and compared with ADTD lightning loc...From January 2020 to December 2021,Ulanqab Meteorological Bureau of Inner Mongolia used VLF/LF lightning locator to carry out three-dimensional lightning monitoring in Ulanqab City,and compared with ADTD lightning location data in the same period.The results show that both VLF/LF lightning locator and ADTD lightning locator had excellent monitoring ability for lightning during flood season in Ulanqab.VLF/LF lightning locator was slightly superior to ADTD lightning locator in observation accuracy,the observation ability of low-current cloud-to-ground lightning,intracloud lightning observation and so on.There were obvious temporal and spatial characteristics of cloud-to-ground lightning during flood season in Ulanqab,and there was a certain correlation between the areas where lightning appeared frequently and surface water.Intracloud lightning was mainly concentrated at a height of 1-7 km.Negative cloud-to-ground lightning accounted for about 75%of total cloud-to-ground lightning,and negative intracloud lightning accounted for 39%of total intracloud lightning.展开更多
Using a 3D lightning radiation source locating system (LLS), three pairs of associated lightning discharges (two or more adjacent lightning discharges following an arbitrary rule that their space-gap was less than ...Using a 3D lightning radiation source locating system (LLS), three pairs of associated lightning discharges (two or more adjacent lightning discharges following an arbitrary rule that their space-gap was less than 10 km and their time-gap was less than 800 ms) were observed, and the interaction between associated lightning discharges was analyzed. All these three pairs of associated lightning discharges were found to involve three or more charge regions (the ground was considered as a special charge region). Moreover, at least one charge region involved two lightning discharges per pair of associated lightning discharges. Identified fl'om electric field changes, the subsequent lightning discharges were suppressed by the prior lightning discharges. However, it is possible that the prior lightning discharge provided a remaining discharge channel to facilitate the subsequent lightning discharge. The third case provided evidence of this possibility. Together, the results suggested that, if the charges in the main negative charge region can be consumed using artificial lightning above the main negative charge regions, lightning accidents on the ground could be greatly reduced, on the condition that the height of the main negative charge region and the charge intensity of the lower positive charge region are suitable.展开更多
Academy of Sciences,Beijing 100029 2 Lanzhou University,Lanzhou 730000 3 Cold and Arid Regions Environmental and Engineering Research Institute, Chinese Academy of Sciences,Lanzhou 730000 4 Nanjing University of Infor...Academy of Sciences,Beijing 100029 2 Lanzhou University,Lanzhou 730000 3 Cold and Arid Regions Environmental and Engineering Research Institute, Chinese Academy of Sciences,Lanzhou 730000 4 Nanjing University of Information Science&Technology,Nanjing 210044 Using both fast and slow electric field change sensors and field mill,multi-station observations on lightning flashes over China inland plateau areas were conducted during the summer of 2004.All of the stations were synchronized by GPS with a time-resolution of±50 ns.Using the different time of arrival(DTOA)and based on the fast electric field change sensor,a lightning radiation location technique was developed.Radiation pulses in the initial stages of five intracloud(IC)lightning discharges which occurred on 20 August were analyzed.The results indicate that the technique developed could effectively locate the lightning radiation sources.Furthermore,the lightning discharges were compared with the Doppler radar data.The results show that the radiation sources were well associated with the storm development.When the storm was at the mature stage with an echo top of about 10.9 km,the radiation sources ranged from 5.2 to 8.3 km above mean sea level;when the storm gradually became weaker,with echo top of about 7.9 km,the radiation sources ranged from 3.0 to 5.9 km.In particular,one of the IC lightning discharges ranged from 3.0 to 4.9 km during the dissipation stage of the storm.The results also indicate that the radiation sources were closely associated with the high reflectivity region(25–50 dBZ)of the storm,which,to some extent,demonstrates the reliability of the location results,thereby showing that multi-station observations of fast electric field change sensors could be a useful tool for monitoring the storm development.Location errors from radiation sources were also compared with the radar data and the results of a simple simulation.It was found that the errors were getting smaller when the radiation sources approached the center of the de展开更多
基于浙江省二维和三维闪电定位系统监测的2019年闪电资料,研究闪电时空分布特征,并评估三维闪电定位系统探测效能。两套系统的地闪频次存在明显的日变化及月变化,集中分布在四月和夏季(6~8月)的午后到傍晚,其中地闪频次较高的时段及月份...基于浙江省二维和三维闪电定位系统监测的2019年闪电资料,研究闪电时空分布特征,并评估三维闪电定位系统探测效能。两套系统的地闪频次存在明显的日变化及月变化,集中分布在四月和夏季(6~8月)的午后到傍晚,其中地闪频次较高的时段及月份,三维系统监测地闪数多于二维系统。二维系统的年雷暴日数是三维系统的近2倍,二维系统存在误测。从强度分布来看,正地闪频次集中区强度值小于负地闪频次集中区,但二维系统的正负地闪强度在0~5 k A之间频次远高于三维系统。两套系统监测的地闪密度南高北低的分布趋势比较一致,高值区位于衢州南部、丽水中部、温州和台州南部一带以及宁波北部地区。但二维系统地闪在站点周边存在明显的放射状分布。另外,三维系统的探测误差仅为二维系统的1/13。上述中二维系统所存在的不足主要是因为其二站定位的探测效率和精度较低,而三维闪电定位系统具有更优的探测效能。展开更多
基金This work was supported by the Chinese Academy of Sciences (Grant No. KZCX2-201) the National Natural Science Foundation of China (Grant No. 49975003)the Key Project (Grant No. 40135010).
文摘The three-dimensional spatial and temporal development of impulsive VHF radiation events during lightning discharges has been analyzed based on the data measured by the lightning mapping array (LMA) system with high space and time resolution. The results indicate that intracloud discharges in the thunderstorm with a normal tripole charge structure occur not only between the upper positive and middle main negative charge region, but also with inverted polarity between the lower positive and middle main negative charge region. The polarity-inverted discharge originates from the middle negative charge and propagates downward to the lower positive region, where then the discharge develops horizontally. The characteristics of the discharge are similar to that of normal intracloud discharge except the polarity opposite. The results further confirmed the existence of the lower positive charge region involved in the lightning discharge. It was also found that the inverted charge structure opposite to the
基金supported by the National Natural Science Foundation of China(Grant No. 40930949)Key Subject Project of Beijing Atmospheric Physics and Environment,the One Hundred Person Project of the Chinese Academy of Sciences
文摘Data from the Beijing SAFIR 3000 lightning detection system and Doppler radar provided some insights into the three-dimensional lightning structure and evolution of a leading-line and trailing-stratiform (LLTS) mesoscale convective system (MCS) over Beijing on 31 July 2007. Most of the lightning in the LLTS-MCS was intracloud (IC) lightning, while the mean ratio of positive cloud-to-ground (+CG) lightning to –CG lightning was 1:4, which was higher than the average value from previous studies. The majority of CG lightning occurred in the convective region of the radar echo, particularly at the leading edge of the front. Little IC lightning and little +CG lightning occurred in the stratiform region. The distribution of the CG lightning indicated that the storm had a tilted dipole structure given the wind shear or the tripole charge structure. During the storm’s development, most of the IC lightning occurred at an altitude of ~9.5 km; the lightning rate reached its maximum at 10.5 km, the altitude of IC lightning in the mature stage of the storm. When the thunderstorm began to dissipate, the altitude of the IC lightning decreased gradually. The spatial distribution of lightning was well correlated with the rainfall on the ground, although the peak value of rainfall appeared 75 min later than the peak lightning rate.
基金This work was supported by the National Natural Science Foundation of China.
文摘From analysis of observational data of thunderstorms in Gansu,China,it was deduced that the electric structure of thunderclouds in this region is often positive charge in the upper,main negative in the middle layer and another positive charge,large in magnitude and extensive in dimension,in the lower part.Intra- cloud discharges often take place between the main negative charge and lower positive charge instead of upper. Case analysis of 6 intracloud discharges in two storms on August 3 and 4,1986 shows that the centers of these discharges and the dipole moments destroyed were at the altitude of 3.8—6 km msl(7.6—-13.5℃)and 18— 40 C km,respectively.
文摘From January 2020 to December 2021,Ulanqab Meteorological Bureau of Inner Mongolia used VLF/LF lightning locator to carry out three-dimensional lightning monitoring in Ulanqab City,and compared with ADTD lightning location data in the same period.The results show that both VLF/LF lightning locator and ADTD lightning locator had excellent monitoring ability for lightning during flood season in Ulanqab.VLF/LF lightning locator was slightly superior to ADTD lightning locator in observation accuracy,the observation ability of low-current cloud-to-ground lightning,intracloud lightning observation and so on.There were obvious temporal and spatial characteristics of cloud-to-ground lightning during flood season in Ulanqab,and there was a certain correlation between the areas where lightning appeared frequently and surface water.Intracloud lightning was mainly concentrated at a height of 1-7 km.Negative cloud-to-ground lightning accounted for about 75%of total cloud-to-ground lightning,and negative intracloud lightning accounted for 39%of total intracloud lightning.
基金supported by the National Natural Science Foundation of China (Grant Nos. 41075002, 41005022, and 40775004)
文摘Using a 3D lightning radiation source locating system (LLS), three pairs of associated lightning discharges (two or more adjacent lightning discharges following an arbitrary rule that their space-gap was less than 10 km and their time-gap was less than 800 ms) were observed, and the interaction between associated lightning discharges was analyzed. All these three pairs of associated lightning discharges were found to involve three or more charge regions (the ground was considered as a special charge region). Moreover, at least one charge region involved two lightning discharges per pair of associated lightning discharges. Identified fl'om electric field changes, the subsequent lightning discharges were suppressed by the prior lightning discharges. However, it is possible that the prior lightning discharge provided a remaining discharge channel to facilitate the subsequent lightning discharge. The third case provided evidence of this possibility. Together, the results suggested that, if the charges in the main negative charge region can be consumed using artificial lightning above the main negative charge regions, lightning accidents on the ground could be greatly reduced, on the condition that the height of the main negative charge region and the charge intensity of the lower positive charge region are suitable.
基金the 100 Talents Program of the Chinese Academy of Sciencesthe Special Research Project for Public Welfare of China under Grant No.200704027-1the National Natural Science Foundation of China under Grant No.40930949
文摘Academy of Sciences,Beijing 100029 2 Lanzhou University,Lanzhou 730000 3 Cold and Arid Regions Environmental and Engineering Research Institute, Chinese Academy of Sciences,Lanzhou 730000 4 Nanjing University of Information Science&Technology,Nanjing 210044 Using both fast and slow electric field change sensors and field mill,multi-station observations on lightning flashes over China inland plateau areas were conducted during the summer of 2004.All of the stations were synchronized by GPS with a time-resolution of±50 ns.Using the different time of arrival(DTOA)and based on the fast electric field change sensor,a lightning radiation location technique was developed.Radiation pulses in the initial stages of five intracloud(IC)lightning discharges which occurred on 20 August were analyzed.The results indicate that the technique developed could effectively locate the lightning radiation sources.Furthermore,the lightning discharges were compared with the Doppler radar data.The results show that the radiation sources were well associated with the storm development.When the storm was at the mature stage with an echo top of about 10.9 km,the radiation sources ranged from 5.2 to 8.3 km above mean sea level;when the storm gradually became weaker,with echo top of about 7.9 km,the radiation sources ranged from 3.0 to 5.9 km.In particular,one of the IC lightning discharges ranged from 3.0 to 4.9 km during the dissipation stage of the storm.The results also indicate that the radiation sources were closely associated with the high reflectivity region(25–50 dBZ)of the storm,which,to some extent,demonstrates the reliability of the location results,thereby showing that multi-station observations of fast electric field change sensors could be a useful tool for monitoring the storm development.Location errors from radiation sources were also compared with the radar data and the results of a simple simulation.It was found that the errors were getting smaller when the radiation sources approached the center of the de
文摘基于浙江省二维和三维闪电定位系统监测的2019年闪电资料,研究闪电时空分布特征,并评估三维闪电定位系统探测效能。两套系统的地闪频次存在明显的日变化及月变化,集中分布在四月和夏季(6~8月)的午后到傍晚,其中地闪频次较高的时段及月份,三维系统监测地闪数多于二维系统。二维系统的年雷暴日数是三维系统的近2倍,二维系统存在误测。从强度分布来看,正地闪频次集中区强度值小于负地闪频次集中区,但二维系统的正负地闪强度在0~5 k A之间频次远高于三维系统。两套系统监测的地闪密度南高北低的分布趋势比较一致,高值区位于衢州南部、丽水中部、温州和台州南部一带以及宁波北部地区。但二维系统地闪在站点周边存在明显的放射状分布。另外,三维系统的探测误差仅为二维系统的1/13。上述中二维系统所存在的不足主要是因为其二站定位的探测效率和精度较低,而三维闪电定位系统具有更优的探测效能。