For dealing with large static error due to poor immunity of the traditional fuzzy control, a novel interval type-2 fuzzy control system is proposed. By extending the typical membership functions to interval type-2 mem...For dealing with large static error due to poor immunity of the traditional fuzzy control, a novel interval type-2 fuzzy control system is proposed. By extending the typical membership functions to interval type-2 membership functions, the proposed control system can efficiently reduce the uncertain disturbance from real environment without increasing the design complexity. The simulation results on the water tank level control system showed that the proposed method succeeded in better static and dynamic control with stronger robust performance than the traditional fuzzy control method.展开更多
Window opening behavior significantly impacts indoor air quality,thermal comfort,and energy consumption.A field measurement was carried out in three typical rooms(a standard office,a meeting room and a smoking office)...Window opening behavior significantly impacts indoor air quality,thermal comfort,and energy consumption.A field measurement was carried out in three typical rooms(a standard office,a meeting room and a smoking office)within an office building.The window state and the physical environment were continuously recorded during the measured periods.Three typical window opening behaviors were found in the measured samples,namely,active,moderate,and passive.The common logistic regression coefficient indicated that solar radiation exhibited the greatest effect on window opening behavior in the smoking office and standard office.Typically,window opening behavior in the meeting room was the most strongly correlated with time of the day,mainly because of the meeting schedule for occupants in the meeting room.This study discussed the dividing principles involved in setting the dummy variable interval level(discretizing continuous variables and dividing them into different intervals),and proposed a method to determine the optimal interval level of each variable.The improved model led to the increase in the prediction accuracy rate of the window being opened by 2.0%and 3.3%according to the comparison with the original model based on dummy variables and the common model based on continuous variables,respectively.This study can provide a reference value for simulating energy consumption in office buildings in the future.展开更多
Let X denote a discrete distribution as Poisson, binomial or negative binomial variable. The score confidence interval for the mean of X is obtained based on inverting the hypothesis test and the central limit theorem...Let X denote a discrete distribution as Poisson, binomial or negative binomial variable. The score confidence interval for the mean of X is obtained based on inverting the hypothesis test and the central limit theorem is discussed and recommended widely. But it has sharp downward spikes for small means. This paper proposes to move the score interval left a little (about 0.04 unit), called by moved score confidence interval. Numerical computation and Edgeworth expansion show that the moved score interval is analogous to the score interval completely and behaves better for moderate means;for small means the moved interval raises the infimum of the coverage probability and improves the sharp spikes significantly. Especially, it has unified explicit formulations to compute easily.展开更多
基金Supported by Program for Liaoning Excellent Talents in University (LJQ2011032)the National Natural Science Foundation of China (61203021)the National Science and Technology Support Program (2012BAF05B00)
文摘For dealing with large static error due to poor immunity of the traditional fuzzy control, a novel interval type-2 fuzzy control system is proposed. By extending the typical membership functions to interval type-2 membership functions, the proposed control system can efficiently reduce the uncertain disturbance from real environment without increasing the design complexity. The simulation results on the water tank level control system showed that the proposed method succeeded in better static and dynamic control with stronger robust performance than the traditional fuzzy control method.
基金The work was supported by the Natural Science Basic Research Program of Shaanxi Province of China(2023-JC-YB-473)the Opening Fund of State Key Laboratory of Green Building in Western China(LSKF202314).The authors would like to express their gratitude to MogoEdit(http://en.mogoedit.com/)for the professional linguistic services provided.
文摘Window opening behavior significantly impacts indoor air quality,thermal comfort,and energy consumption.A field measurement was carried out in three typical rooms(a standard office,a meeting room and a smoking office)within an office building.The window state and the physical environment were continuously recorded during the measured periods.Three typical window opening behaviors were found in the measured samples,namely,active,moderate,and passive.The common logistic regression coefficient indicated that solar radiation exhibited the greatest effect on window opening behavior in the smoking office and standard office.Typically,window opening behavior in the meeting room was the most strongly correlated with time of the day,mainly because of the meeting schedule for occupants in the meeting room.This study discussed the dividing principles involved in setting the dummy variable interval level(discretizing continuous variables and dividing them into different intervals),and proposed a method to determine the optimal interval level of each variable.The improved model led to the increase in the prediction accuracy rate of the window being opened by 2.0%and 3.3%according to the comparison with the original model based on dummy variables and the common model based on continuous variables,respectively.This study can provide a reference value for simulating energy consumption in office buildings in the future.
文摘Let X denote a discrete distribution as Poisson, binomial or negative binomial variable. The score confidence interval for the mean of X is obtained based on inverting the hypothesis test and the central limit theorem is discussed and recommended widely. But it has sharp downward spikes for small means. This paper proposes to move the score interval left a little (about 0.04 unit), called by moved score confidence interval. Numerical computation and Edgeworth expansion show that the moved score interval is analogous to the score interval completely and behaves better for moderate means;for small means the moved interval raises the infimum of the coverage probability and improves the sharp spikes significantly. Especially, it has unified explicit formulations to compute easily.